The FSW-9000 Series is a flow
switch monitor that measures the
velocity of the flow. It is ideal for
use in measurement and control
liquid applications. The FSW-9000
Series provides two output options:
a 4 to 20 mA analog output and a
PNP/NPN output. For the 4 to
20 mA output, the electronics’
module converts the signal from
the probe to a 4 to 20 mA analog
output, which can be used to
indicate flow rate. For the
PNP/NPN output, the measured
flow rate is compared to the
setpoint value selected by the user
and the switch changes state once
the setpoint value has been
achieved.
The FSW-9000 Series
microprocessor based electronics
and unique self-calibration program
gives the flow switch superior
temperature compensation, a fast
response time (adjustable from
3 to 10 seconds) and increased
long term switch point stability.
Even in the event of a power
failure, the calibration program will
store values for maximum and
minimum flows for up to 10 years.
A chain of 8 LEDs gives the user a
visual indication of the flow rate as
well as setpoint status, and one
di-chromatic LED indicates switch
point status. In addition, if there is a
problem with the unit, the 8 LEDs
will flash continuously providing
troubleshooting information.
The conical shape of the sensor’s
tip means that the probe can be
installed at almost any angle in the
pipe and that if the probe is
misaligned, accuracy will not be
affected. The sensing element and
connection of the FSW-9000 Series
are made with 316 SS and the
standard enclosure is glass-filled
nylon. The FSW-9000 Series can
be made with a great variety of
process connections such as
threaded, flange, or sanitary and is
also available in an aluminum
enclosure for hazardous
environments. Intrinsic safety
barriers required for explosion proof
areas.
Measuring Ranges for
FSW-9000 Series
The FSW-9000 Series nominal
measuring range is 0.04 to 2.0 m/s.
The switch can be set to trip at any
value in this range. To calculate the
velocity for your application, use the
following simple formula:
1.27 X Q
V=
Q = Flow rate in meters per second
D = Pipe internal diameter in meters
V = Fluid velocity in meters per second
D
B-83
2
Please note that the 4 to 20 mA
option is scaled over 0 to 2.0 m/s
The FSW-90-R is very similar to the
FSW-9212 Series with one main
difference: The sensor is separate
from the electronics and it does not
have an enclosed housing. This
gives the FSW-90-R Series the
ability to be installed in very small
pipes and be remotely controlled by
the FSCN-91 relay. The FSW-90-R
Series is the ideal solution when
there is not a lot of space to install
even a compact unit or when there
is a need for a mounted relay. In
addition, the conical shape of the
sensor’s tip allows the probe to be
installed at almost any angle in the
pipe, and if it is misaligned,
accuracy will not be affected. The
FSW-90-R is made with 316 SS.
FSCN-91 relay can operate with
DC or AC supply voltage and
provides an analog 4 to 20 mA
and SPDT output. The FSCN-91
enclosure is made with ABS and
can be mounted on a DIN rail or by
using 2 fixing screws.
FSW-9212, $745,
shown smaller
than actual size.
SPECIFICATIONS
Accuracy: ±5% of setpoint
Repeatability: ±1% of setpoint
Power Supply: FSW-90-R: 85 to
Calibrators, Connectors, General Test and Measurement
Instruments, Glass Bulb Thermometers, Handheld Instruments
for Temperature Measurement, Ice Point References,
Indicating Labels, Crayons, Cements and Lacquers, Infrared
Temperature Measurement Instruments, Recorders Relative
Humidity Measurement Instruments, RTD Probes, Elements
and Assemblies, Temperature & Process Meters, Timers and
Counters, Temperature and Process Controllers and Power
Switching Devices, Thermistor Elements, Probes and
Assemblies,Thermocouples Thermowells and Head and Well
Assemblies, Transmitters, Wire
Flow and Level
Air Velocity Indicators, Doppler Flowmeters, Level
Measurement, Magnetic Flowmeters, Mass Flowmeters,
Pitot Tubes, Pumps, Rotameters, Turbine and Paddle Wheel
Flowmeters, Ultrasonic Flowmeters, Valves, Variable Area
Flowmeters, Vortex Shedding Flowmeters
pH and Conductivity
Conductivity Instrumentation, Dissolved Oxygen
Instrumentation, Environmental Instrumentation, pH
Electrodes and Instruments, Water and Soil Analysis
Instrumentation
Data Acquisition
Auto-Dialers and Alarm Monitoring Systems,
Communication Products and Converters, Data
Acquisition and Analysis Software, Data Loggers
Plug-in Cards, Signal Conditioners, USB, RS232, RS485
and Parallel Port Data Acquisition Systems, Wireless
Transmitters and Receivers
Band Heaters, Cartridge Heaters, Circulation Heaters,
Comfort Heaters, Controllers, Meters and Switching
Devices, Flexible Heaters, General Test and Measurement
Instruments, Heater Hook-up Wire, Heating Cable
Systems, Immersion Heaters, Process Air and Duct,
Heaters, Radiant Heaters, Strip Heaters, Tubular Heaters
click here to go to the omega.com home page
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.