Omega Products FPUDX1701A User Manual

DUAL-HEAD INJECTOR METERING PUMPS
FPUDX1700A
Series
U Simple Intake and
Discharge Check Valve Design
U Quick-Adjusting
U Dual Side-Mounted
Cartridge Valve Heads
U Each Head Independently
Controlled
U Top-Mounted Feed
Adjustment
U 100% Duty Cycle
FPUDX1700A Series dual-head injector pumps feature side-mounted heavy-duty cartridge valve heads. Coming in contact with liquid, the durable end of these pumps is made of injection-molded polypropylene and has double-sealed PVDF cartridge valve fittings, FKM O-ring seals, ceramic ball checks, Hastelloy valve springs, and a PTFE/EPDM diaphragm. The user can easily control each head with a top-mounted feed adjustment. These pumps are suitable for a variety of applications, including injecting different amounts of similar chemicals into separate systems and feeding 2 different chemicals into the same system. One should also use these pumps if a single-head pump does not provide sufficient output.
FPUDX17001A shown smaller than actual size.
Includes Check Valves,
Flow Indicator, Injection and
Foot Valves, 1.5 m (5') Each
of Vinyl Suction Tubing
and Polyethylene
Discharge Tubing
SPECIFICATIONS
Output Accuracy: ±10% of maximum
[water @ 21°C (70°F) and 1.5 m (5') suction lift] O-Ring: FKM standard; ethylene propylene, silicone optional
Turndown Ratio: 10:1 Power: 115/60 Hz, optional
230V/60 Hz, 220V/50 Hz, 24 V/60 Hz Dimensions: 241 H x 191 W x 102 mm D (9.5 x 7.5 x 4")
Shipping Weight: 4.5 kg (10 lb) Tube Dimensions: Maximum Fluid Temperature:
54°C (130°F) Enclosure: NEMA 3R (IP24) (acceptable for outdoor use)
Maximum Viscosity: 1000 centipoise Maximum Suction Lift: Up to 3 m (10')
of waterimum
3
8" OD, 1⁄4" ID
To Order Visit omega.com/fpudx1700 for Pricing and Details
Model No. Maximum GPD mL/min Strokes/min Maximum psi FPUDX1701A 34.2 90 30 125
FPUDX1702A 89.7 236 45 125 FPUDX1703A 133.8 352 125 125 FPUDX1704A 304.2 800 125 20
Comes complete with valves, 1.5 m (5') each of vinyl suction tubing and polyethylene discharge tubing.
For 230 V/60 Hz voltage, add suffix “-230V60” to model number For 220 V/50 Hz voltage, add suffix “-220V50” to model number (maximum GPD decreases by
20%)
, for additional cost. For 24 V/60 Hz voltage, add suffix “-24V60” to model number Ordering Examples: FPUDX1701A, pump with 32.7 GPD (86 mL/min) range,125 psi maximum,
30 strokes/min. FPUDX1704A, pump with 285.3 GPD (750 ml/min) range.
operator’s manual, check valves, flow indicator, injection and foot
, for additional cost.
, for additional cost.
L-9