Variable Speed and
Fixed Timer periSTalTic pumpS
FPU2000 Series
U Peristaltic Pump Tube
Does Not Require Valves
U Self Priming
U High Outlet Pressure
Capability of 100 psig on
Most Models
U Acceptable for
Indoor Use
U Corrosion Proof Valox
Housing
U Tamper Resistant
Electronic Control
Panel Cover
U Tube Failure Detection
The FPU2000 Series fixed pumps
feed by an analog fixed 60 second
timer. The pump can be on for
1 to 60 seconds. All FPU2000 Series
have fixed speed outputs and can be
adjusted by selecting the pumphead
tube size and choosing the desired
RPM (revolutions per minute).
The FPUVS2000 and FPUDVS2000
Series variable speed pumps are
for continuous pumping relatively
pulse free, even while adjusting the
percentage of output. The variable
speed pump requires the use of
brushes on the DC motor. Excellent
brush life expectancy (2000 hours).
An extra set of brushes included
with every pump. The FPUDVS2000
Series will accept any one of three
different types of external input
signals; 4 to 20 mA, 0 to 10 Vdc,
or frequency. The 4 to 20 mA and
0 to 10 Vdc loops must be powered.
Two types of frequency inputs, AC
sine waves (magnetic coils type
outputs) and digital square waves
(Hall Effect signals, contact
closures), are acceptable. A jumper
plug located on the circuit board
is factory pre-set for AC sine wave
signals, the jumper must be
re-positioned when digital square
wave signals are being used. All
wiring connections are to be made
inside of the junction box located
L-21
FPUDVS2003,
shown smaller
than actual size.
on the side of the FPUDVS2000
Series. A liquid tight connector is
supplied and should be used for
the external signal cable. The signal
input wires are color coded to the
type of signal being used.
SPECIFICATIONS
Maximum Working Pressure:
100 psig/6.9 bar (most models)
Maximum Fluid Temperature:
54°C (130°F)
Ambient Temperature Range:
-10 to 43°C (14 to 110°F)
Enclosure: NEMA 3R (IP24)
(acceptable for indoor use)
Pump Tube Material: Norprene
Duty Cycle: Continuous
Maximum Solids: 50% by volume
Maximum Viscosity: 5000 Centipoise
Maximum Suction Lift:
Up to 9 m (30') water
Turn Down Ratio: 20:1
Power Requirements: 115 V 60 Hz
80 Watts, 220 V 50 Hz 40 Watts,
FPUVS2003, shown
smaller than actual size.
230 V 60 Hz 45 Watts
Variable Speed: 115 V 60 Hz
40 Watts, 220 V 50 Hz 40 Watts,
230 V 60 Hz 40 Watts
Dimensions:
155.6 H x 257.2 W x 228.6 mm D
1
⁄8 x 101⁄8 x 9")
(6
Variable Speed:
159 H x 254 W x 235 mm D
1
⁄4 x 10 x 91⁄4")
(6
Weight: 3.6 kg (8 lb)
Tube Connection: Compression barb
3
⁄8” ID x 1⁄4" OD)
type (
To Order Visit omega.com/fpu2000 for Pricing and Details
Peristaltic Pumps
Max Strokes/
Model No. Variable Speed Variable Speed Max Feed Rate Minute
Fixed-Timer Standard Digital Percentage Pump Tube
Control Percentage Controllers OD (inch) mL/min GPD PSI RPM
FPU2001 FPUVS2001 FPUDVS2001 ¹⁄₄ 6 2.3 100 14
FPU2002 FPUVS2002 FPUDVS2002 ¹⁄₄ 13 4.9 100 30
FPU2003 FPUVS2003 FPUDVS2003 ¹⁄₄ 21 8 100 45
FPU2004 FPUVS2004 FPUDVS2004 ¹⁄₄ 25 9.5 75 60
FPU2005 FPUVS2005 FPUDVS2005 ³⁄₈ 18 6.8 100 14
FPU2006 FPUVS2006 FPUDVS2006 ³⁄₈ 42 16 100 30
FPU2007 FPUVS2007 FPUDVS2007 ³⁄₈ 63 24 100 45
FPU2008 FPUVS2008 FPUDVS2008 ³⁄₈ 79 30.1 75 60
FPU2009 FPUVS2009 FPUDVS2009 ⁷⁄₁₆ 57 21.7 50 14
FPU2010 FPUVS2010 FPUDVS2010 ⁷⁄₁₆ 138 52.5 50 30
FPU2011 FPUVS2011 FPUDVS2011 ⁷⁄₁₆ 200 76.1 50 45
FPU2012 FPUVS2012 FPUDVS2012 ⁷⁄₁₆ 250 95.1 50 60
Accessories
Model No. Description
TYSP5F-3814-50 15 m (50') spool of ³⁄₈ x ¹⁄₄" santoprene tubing
FPU2000-14PTA ¹⁄₄" OD pump tube assembly
FPU2000-38PTA ³⁄₈" OD pump tube assembly
FPU2000-716PTA ⁷⁄₁₆" OD pump tube assembly
FPU2000-RA Roller assemblies for ¹⁄₄ and ³⁄₈" tube models
FPU2000-716RA Roller assemblies for ⁷⁄₁₆" tube model
FPU2000-PHB Pump head cover with bearing
FPU2000-PH Pump head
FPU1000-AB Quantity 2, armature bearings
FPU1000-IF Injection fitting
FPU2000-TN Tube nut (³⁄₈")
FPU2000-CW Ceramic weight
FPU2000-SP Strainer plug
Comes complete with suction tube strainer, tube weight, suction tubing, discharge tubing, and injection fitting with internal back-flow check
valve, mounting hardware, and operator’s manual. FPUVS and FPUDVS come with an additional set of brushes.
To order 220 Vac/50Hz model add suffix “-220/50” to model number, no additional charge. To order 230 Vac/60 Hz model add suffix “-230/60”
to model number, no additional charge. Note: 220 Vac/50Hz fixed speed models output approximately 20% less.
Ordering Examples: FPUDVS2007 digital pump 24 GPD.
FPU2001, fixed timer controlled pump 2.3 GPD.
L-22
L