
Variable Speed and  
Fixed Timer periSTalTic pumpS
FPU2000 Series
U Peristaltic Pump Tube 
Does Not Require Valves
U Self Priming 
U High Outlet Pressure 
Capability of 100 psig on 
Most Models 
U Acceptable for 
Indoor Use
U Corrosion Proof Valox 
Housing
U Tamper Resistant 
Electronic Control 
Panel Cover
U Tube Failure Detection
The FPU2000 Series fixed pumps 
feed by an analog fixed 60 second 
timer. The pump can be on for  
1 to 60 seconds. All FPU2000 Series 
have fixed speed outputs and can be 
adjusted by selecting the pumphead 
tube size and choosing the desired 
RPM (revolutions per minute). 
The FPUVS2000 and FPUDVS2000 
Series variable speed pumps are 
for continuous pumping relatively 
pulse free, even while adjusting the 
percentage of output. The variable 
speed pump requires the use of 
brushes on the DC motor. Excellent 
brush life expectancy (2000 hours). 
An extra set of brushes included 
with every pump. The FPUDVS2000 
Series will accept any one of three 
different types of external input 
signals; 4 to 20 mA, 0 to 10 Vdc,  
or frequency. The 4 to 20 mA and  
0 to 10 Vdc loops must be powered. 
Two types of frequency inputs, AC 
sine waves (magnetic coils type  
outputs) and digital square waves 
(Hall Effect signals, contact  
closures), are acceptable. A jumper 
plug located on the circuit board 
is factory pre-set for AC sine wave 
signals, the jumper must be  
re-positioned when digital square 
wave signals are being used. All 
wiring connections are to be made 
inside of the junction box located 
L-21
FPUDVS2003, 
shown smaller 
than actual size.
on the side of the FPUDVS2000 
Series. A liquid tight connector is 
supplied and should be used for 
the external signal cable. The signal 
input wires are color coded to the 
type of signal being used.
SPECIFICATIONS
Maximum Working Pressure: 
100 psig/6.9 bar (most models) 
Maximum Fluid Temperature: 
54°C (130°F) 
Ambient Temperature Range: 
-10 to 43°C (14 to 110°F) 
Enclosure: NEMA 3R (IP24) 
(acceptable for indoor use)
Pump Tube Material: Norprene 
Duty Cycle: Continuous 
Maximum Solids: 50% by volume 
Maximum Viscosity: 5000 Centipoise 
Maximum Suction Lift: 
Up to 9 m (30') water
Turn Down Ratio: 20:1

Power Requirements: 115 V 60 Hz 
80 Watts, 220 V 50 Hz 40 Watts, 
FPUVS2003, shown 
smaller than actual size.
230 V 60 Hz 45 Watts 
Variable Speed: 115 V 60 Hz 
40 Watts, 220 V 50 Hz 40 Watts,  
230 V 60 Hz 40 Watts 
Dimensions: 
155.6 H x 257.2 W x 228.6 mm D 
1
⁄8 x 101⁄8 x 9")
(6 
Variable Speed: 
159 H x 254 W x 235 mm D 
1
⁄4 x 10 x 91⁄4")
(6
Weight: 3.6 kg (8 lb) 
Tube Connection: Compression barb 
3
⁄8” ID x 1⁄4" OD)
type (
To Order Visit omega.com/fpu2000 for Pricing and Details
 Peristaltic Pumps 
                 Max Strokes/  
 Model No.  Variable Speed  Variable Speed           Max Feed Rate        Minute 
 Fixed-Timer  Standard  Digital Percentage  Pump Tube       
 Control  Percentage  Controllers  OD (inch)  mL/min  GPD  PSI  RPM 
 FPU2001  FPUVS2001  FPUDVS2001  ¹⁄₄  6  2.3  100  14 
 FPU2002  FPUVS2002  FPUDVS2002  ¹⁄₄  13  4.9  100  30 
 FPU2003  FPUVS2003  FPUDVS2003  ¹⁄₄  21  8  100  45 
 FPU2004  FPUVS2004  FPUDVS2004  ¹⁄₄  25  9.5  75  60 
 FPU2005  FPUVS2005  FPUDVS2005  ³⁄₈  18  6.8  100  14 
 FPU2006  FPUVS2006  FPUDVS2006  ³⁄₈  42  16  100  30 
 FPU2007  FPUVS2007  FPUDVS2007  ³⁄₈  63  24  100  45 
 FPU2008  FPUVS2008  FPUDVS2008  ³⁄₈  79  30.1  75  60 
 FPU2009  FPUVS2009  FPUDVS2009  ⁷⁄₁₆  57  21.7  50  14 
 FPU2010  FPUVS2010  FPUDVS2010  ⁷⁄₁₆  138  52.5  50  30 
 FPU2011  FPUVS2011  FPUDVS2011  ⁷⁄₁₆  200  76.1  50  45 
 FPU2012  FPUVS2012  FPUDVS2012  ⁷⁄₁₆  250  95.1  50  60
Accessories
 Model No.  Description 
 TYSP5F-3814-50  15 m (50') spool of ³⁄₈ x ¹⁄₄" santoprene tubing 
 FPU2000-14PTA  ¹⁄₄" OD pump tube assembly 
 FPU2000-38PTA  ³⁄₈" OD pump tube assembly 
 FPU2000-716PTA  ⁷⁄₁₆" OD pump tube assembly 
 FPU2000-RA  Roller assemblies for ¹⁄₄ and ³⁄₈" tube models 
 FPU2000-716RA  Roller assemblies for ⁷⁄₁₆" tube model 
 FPU2000-PHB  Pump head cover with bearing 
 FPU2000-PH  Pump head  
 FPU1000-AB  Quantity 2, armature bearings 
 FPU1000-IF  Injection fitting 
 FPU2000-TN  Tube nut (³⁄₈")
 FPU2000-CW  Ceramic weight 
 FPU2000-SP  Strainer plug
Comes complete with suction tube strainer, tube weight, suction tubing, discharge tubing, and injection fitting with internal back-flow check 
valve, mounting hardware, and operator’s manual. FPUVS and FPUDVS come with an additional set of brushes.
To order 220 Vac/50Hz model add suffix “-220/50” to model number, no additional charge. To order 230 Vac/60 Hz model add suffix “-230/60”  
to model number, no additional charge. Note: 220 Vac/50Hz fixed speed models output approximately 20% less.
Ordering Examples: FPUDVS2007 digital pump 24 GPD. 
FPU2001, fixed timer controlled pump 2.3 GPD.
L-22
L