Omega Products FPU101 User Manual

®
OMEGAFLEX
OEM STYLE
PERISTALTIC PUMPS
FPU100 Series
Starts at
$
FPU101 pump, $78, shown smaller than actual size, supplied with Norprene tubing and mounting panel.
FPU4500, $209, shown smaller than actual size.
UL-Listed AC or DC MotorSuitable for Fluids Carrying
Small Particles
Easy to MaintainMounting Panel StandardBenchtop Case OptionalNew High-Flow FPU4500 Series Has
2000 mL/Min Capacity
FPU100 Series peristaltic pumps offer simplicity at a reduced cost. The UL-listed AC or DC motor turns the rollers, which squeeze fluid through the precision-bore high-tolerance tubing in a wavelike motion, acting like a positive displacement pump. The fluid doesn’t touch the pump; it only comes into contact with the tubing. This makes the pump suitable for fluids carrying small particles. FPU100 pumps continuously overocclude the tubing, which makes the pump self-priming and non-siphoning. They are easy to maintain, with few moving parts and no seals or valves to clog, clean, or replace. As one section of tube fatigues, just move the tubing to a section that hasn’t been under the rollers and continue pumping. Or simply replace the supplied tubing. The replacement 230 mm (9") lengths
of precision-bore tubing ensure repeatable pumping rates time after time. The pumps are supplied with tubing that has polyethylene union connectors for hooking up system tubing. The replacement 230 mm (9") lengths of tubing come without connectors. The pumps are supplied standard with a mounting panel. The AC-powered pumps are also available in a rugged polycarbonate enclosure for bench mounting. Maximum backpressure is 15 psi without derating (up to 25 psi @ 75% of maximum flow). Maximum suction head is
8.5 m (28'). Flow rate repeatability from one pump to the next or when replacing tubing is within 8% of maximum flow rate listed. Shipping weight is 1.6 kg (3.5 lb) for all sizes. These pumps are ideal for metering/dosing, repetitive dispensing, and general liquid/gas transfer, and they have a 100% duty cycle for continuous operation.
SPECIFICATIONS (FPU100)
Mounting Plate: 94 L x 130 W x 109 mm D
(3.74 x 5.12 x 4.28"); 5.6 mm (0.22") diameter holes are centered 76 x 110 mm (3.0 x 4.34") on the plate For units with rear fan: 130 L x 130 W x 135 mm D (5.11 x 5.12 x 5.28") overall
Case: 152 H x 152 W x 102 mm D (6 x 6 x 4") Shipping Weight: 1.6 kg (3.5 lb) Ambient Temp Range: 20 to 30°C (68 to 86°F) Max Liquid Viscosity: 8500 cp
SPECIFICATIONS (FPU4500)
Electrical: 115 Vac/60 Hz Flow Rate: 2000 mL/min (78.6 oz) Mounting: 12-gage zinc-plated steel mounting plate (included) Dimensions: 140 H x 116 W x 191 mm D (5.5 x 4.6 x 7.5") Shipping Weight: 2.4 kg (5.3 lb)
L-25
For a Complete
®
Selection of OMEGAFLEX
Tubing and Accessories,
See Section T
Pages T-13 to T-66
Benchtop Case Available
The AC-powered pumps are also available in a rugged polycarbonate enclosure with on/off switch, power indicator lamp, and rubber feet for benchtop use. Each is supplied with a 1.8 m (6'), 115 Vac, 3-wire cord. To order, select the desired pump. Add suffix “-CASE” to model number and add $75 to price. For 240 Vac models with European plug, consult OMEGA’s Flow Department. An optional 24-hour timer with momentary “on” switch for priming the pump is also available for the case unit. The timer is settable up to 24 hours in increments of 15 minutes by internal DIP switches. To order case unit with timer for 115 Vac, add suffix “-CASE-CT” to model number and add $95 to price.
Replacement 230 mm (9") Tubing Lengths
Model No. Price (ID x OD)
FPU116-S $6
FPU18-N 4
FPU18-S 4
FPU316-N 4
FPU316-S 4
FPU14-N 4
FPU14-S 4
Tubes are supplied inserted into
*
tubes. Connection is made to the internal tubing.
Brushless 115 Vac, 60 Hz induction motors; flow rates based on pumping water.
Recommended Reference Book:
Systematic Methods
of Chemical Process Design
CM-4441, $112.
For Additional Books
Description
1
" x
16
silicone tubing*
1
" x
8
Norprene tubing
1
" x
8
tubing
3
" x
16
Norprene tubing
3
" x
16
silicone tubing
1
" x
4
Norprene tubing
1
" x
4
silicone tubing
See Section Y
1
"
8
3
"
8
3
" silicone
8
3
"
8
3
"
8
7
"
16
7
"
16
3
1
16
3
" x
"
16
8
1
" x
"
8
FPU111-CASE, $153, shown smaller than actual size.
MOST POPULAR
MODELS HIGHLIGHTED!
To Order (Specify Model Number) Norprene Tube Standard
Approx. Flow Rate Average Tube Life Model @ 60 Hz Tube Silicone Norprene No. Price mL/Min GPM ID Hours†Hours†rpm Amperage**
FPU101 $78 3 0.0008 FPU102 78 5 0.0013 FPU103 78 6 0.0016 FPU104 78 12 0.0032 FPU105 78 20 0.0052 FPU106 78 25 0.0065 FPU107 78 30 0.008 FPU108 78 45 0.012 FPU109 78 50 0.013 FPU110 78 55 0.015 FPU111 78 70 0.018 FPU112 78 80 0.022 FPU113 78 100 0.026 FPU114 78 100 0.026 FPU115 78 115 0.030 FPU116 78 130 0.034 FPU117 95 150 0.040 FPU118 95 165 0.044 FPU119 95 195 0.052 FPU120 95 250 0.066 FPU121 95 360 0.095 FPU122 95 425 0.110 FPU123 125 635 0.168 FPU124 125 750 0.200 FPU125 125 1000 0.265
FPU4500* 209 2000 0.528
Comes complete with operator’s manual and mounting panel.
The FPU4500 comes with Norprene tubing (not available as a case unit with timer).
*
(FPU100 Series)
240 Vac amperage is
**
units, consult OMEGA’s Flow Engineering Department.
Pumps are supplied with Norprene tubes standard. For silicone tubing, add suffix “-SL” to model
number, no additional charge. Note: DC-powered versions have a 500 hr life; for long-term or continuous applications, use the
standard 115 Vac powered models. For units powered by 12 or 24 Vdc, add suffix “-12VDC” or “-24VDC” to the model number and $20 to the price.
For units powered by 240 Vac @ 50 Hz, add suffix “-240VAC” to model number and $10 to price. 50 Hz units have approximately
For dual head units with 2 separate outputs, add suffix “-DUAL” to model number and $45 to price, for FPU101 through FPU120. For FPU121 through 125-DUAL, add $70 to price.
Ordering Examples: FPU119-240VAC-DUAL, 240 Vac, 50 Hz powered, dual-head unit with a total
5
flow of
FPU109-SL, 50 mL/min pump with silicone tube, $78. FPU107-CASE, pump with polycarbonate enclosure, $78 + 75 = $153.
x 2000 mL/min = 1666 mL/min, $95 + 10 + 45 = $150.
6
1
that for 115 Vac; for 24 Vdc power, 0.8 A nominal max. For dual-head
2
5
6
L-26
1
" 2600 5200 14 0.37
16
1
" 1600 3200 23 0.42
16
1
" 1300 2600 28 0.75
16
1
" 2600 5200 14 0.37
8
1
" 1600 3200 23 0.42
8
1
" 1300 2600 28 0.75
8
3
" 2600 5200 14 0.37
16
3
" 1600 3200 23 0.42
16
1
" 2600 5200 14 0.37
4
3
" 1300 2600 28 0.75
16
3
" 1000 2000 36 0.90
16
1
" 1600 3200 23 0.42
4
3
" 750 1500 48 1.00
16
1
" 1300 2600 28 0.75
4
3
" 600 1200 58 1.20
16
1
" 1000 2000 36 0.90
4
3
" 500 1000 75 1.50
16
1
" 750 1500 48 1.00
4
1
" 600 1200 58 1.20
4
1
" 500 1000 75 1.50
4
1
" 350 700 108 1.90
4
1
" 300 600 129 2.20
4
1
" 200 400 172 2.20
4
1
" 180 360 203 2.20
4
1
" 130 260 282 2.20
4
3
" 500 1000 154 3.80
8
of the capacity of standard 60 Hz units.
L
Loading...