Omega Products FPT-6310 User Manual

HIGH ACCURACY PITOT TUBES
FPT-6300 Series
place, then the ball valve and packing are put in place. Next, a drill is used to drill out the pipe. The drill is partially withdrawn and the ball valve is closed. The drill may then be completely removed and the sensing tube partially installed in the assembly. Finally, the ball valve is opened and the sensing tube is inserted into the flowstream. The FPT-6300 is ideal for retrofits on critical flowstreams.
SPECIFICATIONS
Accuracy, Repeatability and Unrecoverable Pressure Drop: Same
as the FPT-6100 series Max Temperature/Pressure: 88°C (190°F) at 150 psig operating; 88°C (190°F) at 100 psig during insertion or removal Wetted Parts: Carbon steel weld coupling and pipe fittings, brass ball valve and packing, and Zytel ferrule. For 316SS construction, consult Flow Engineering Department.
FPT-6320, shown smaller than actual size.
U Up to ±1% of
Rate Accuracy
U Wet Tap Assembly
Permits Installation/ Removal in Live Lines
U Very Low Pressure Drop U Low Maintenance U For Clean, Low Viscosity
Liquids, Gases, & Steam
The FPT-6300 averaging pitot tube is similar to the FPT-6100 in performance, but features a wet-tap assembly which permits installation and removal of the sensor in pressurized lines without process shutdown. The weld coupling is first welded into
Wet tap mounting assembly
Ball valve
Weld coupling
Pressure safety chain
To Order Visit omega.com/fpt6300 for Pricing and Details
Max Model Nominal Probe Differential Max Weight A* No. Line Size Dia.
FPT-6310 1" FPT-6312 11⁄4" FPT-6315 11⁄2" FPT-6320 2" FPT-6325 21⁄2" FPT-6330 3" FPT-6335 31⁄2" FPT-6340 4" FPT-6350 5" FPT-6360 6" FPT-6380 8" FPT-6381 10" FPT-6382 12" FPT-6383 14" FPT-6384 16" FPT-6385 18" FPT-6386 20" FPT-6387 24" FPT-6388 30"
Comes complete with operator’s manual
Please complete and send in questionnaire from omega.com/flowq with your order.
This dimension + nominal line size = approximate overall length. This dimension + nominal
*
line size + 5 inches = approximate minimum distance required for probe removal Ordering Example: FPT-6310, high accuracy pitot tube.
Pressure (H2O)
3
8" 1200 115 0.517 1.2 (2.6) 103⁄8
3
8" 833 179 0.583 1.2 (2.6) 103⁄4
3
8" 668 220 0.580 1.2 (2.6) 11
3
8" 459 315 0.638 1.2 (2.6) 111⁄2
3
8" 338 419 0.617 1.2 (2.7) 121⁄2
3
8" 237 552 0.665 1.3 (2.8) 133⁄4
3
8" 186 657 0.661 1.3 (2.8) 141⁄2
3
8" 150 756 0.672 1.3 (2.9) 151⁄2
3
8" 101 956 0.671 1.4 (3.0) 171⁄2
3
8" 72 1230 0.706 1 (3.1) 191⁄2
3
4" 164 3109 0.686 2.9 (6.29) 253⁄8
3
4" 107 4006 0.676 3.1 (6.77) 293⁄8
3
4" 77 4830 0.683 3.2 (7.10) 331⁄8
3
4" 65 5443 0.698 3.3 (7.33) 353⁄8
3
4" 50 6171 0.688 3.5 (7.72) 39
3
4" 40 7195 0.689 3.7 (8.11) 423⁄4
3
4" 32 8173 0.686 3.9 (8.51) 461⁄2
3
4" 22 10210 0.789 4.3 (9.41) 547⁄8
3
4" 14 12948 0.720 4.8 (10.63) 661⁄2
GPM K kg (lb) (inch)
G-X