Omega Products FPD1004 User Manual

POSITIVE DISPLACEMENT HIGH FLOWMETERS FOR VISCOUS FLUIDS
FPD1004
U 0 to 1000 cP Viscosity
Standard, 1,000,000 cP Viscosity Rotor Also Available
U Compact, Durable, and
Serviceable On-Site
U Extremely Accurate Even
U Meter Design Minimizes
the Number of Wearable Parts—Extending Product Life
U Reed Switch or
Hall Effect Sensor
U Handles Particle Sizes to
0.28 mm (0.011")
SPECIFICATIONS
Accuracy: ±0.5% rdg Repeatability: ±0.03% Fitting Type: FNPT, flange and
tri-clover sanitary fittings optional on some models
Sensor Options: Reed switch (2-wire SPST reed switch N/O, 3 watts rated, 150 Vdc max) or hall effect sensor (25 mA NPN open collector)
Hall Effect Sensor—Power Requirements: Dedicated 4.5 to 24 Vdc
(4.6 to 9 mA)
Meter Length Height
Maximum Viscosity: 1000 cP Body: Aluminum; not recommended for
water applications Strainer Size: 60 mesh [handles
particle sizes to 0.28 mm (0.011")] Mounting: Shafts must be in a
horizontal plane; cap screws should not point up or down
Wetted Materials Housing Aluminum (Std) Stainless Steel PPS
Bearings for 1" units Carbon/graphite Carbon/graphite PPS Bearings for ¹⁄₂ to 2" units PPS PPS N/A Shaft 316 SS 316 SS Hastelloy C Rotor for ¹⁄₂, ³⁄₄, 1¹⁄₂, 2" PPS PPS N/A Rotor for 1" units 316 SS 316 SS PPS O-ring FKM FKM PTFE
Size mm (inch) mm (inch) ¹⁄₂" 100.0 (3.94) 96.0 (3.78)
³⁄₄" 133.0 (5.24) 126.0 (4.96) 1" PPS 107.9 (4.25) 100.0 (3.94) 1" AL/SS 170.1 (6.70) 112.0 (4.41) 1¹⁄₂" 212.0 (8.35) 144.0 (5.67) 2" 240.0 (9.45) 178.0 (7.01)
FPD1000D-TX remote 4 to 20 mA output with programmable display
(loop powered), shown
smaller than actual size.
FPD1004, shown smaller than actual size.
Weight Max Temp Max Pressure Typical Frequency Meter Size kg (lb) °C (°F) bar (psi) K Factors (PPG) Range (Hz)
¹⁄₂" Aluminum 1.50 (3.25) 80 (176) 55 (800) 424.0 1.8 to 55.8 ¹⁄₂" SS 2.70 (6.0) 120 (248) 55 (800) 424.0 1.8 to 55.8 3⁄4" Aluminum 1.9 (4.3) 80 (176) 55 (800) 197.0 2.6 to 51.9 1" PPS body 1.30 (1.3) 80 (176) 10 (150) 197.0 2.6 to 69.0 1" Aluminum 2.20 (4.9) 80 (176) 55 (800) 136.3 3.6 to 72.7 1" Al w/150# flange 2.90 (6.6) 80 (176) Flange Rule 136.3 3.6 to 72.7 1 SS 5.70 (12.7) 120 (248) 55 (800) 136.3 3.6 to 72.7 1 SS w/150# flange 6.60 (14.6) 120 (248) Flange Rule 136.3 3.6 to 72.7 1 SS w/tri-clover fittings 4.90 (10.8) 120 (248) 55 (800) 136.3 3.6 to 72.7 1¹⁄₂" Aluminum 4.50 (10.0) 80 (176) 55 (800) 54.9 2.4 to 60.4 1¹⁄₂ Al w/150# flange 5.40 (12.0) 80 (176) Flange Rule 54.9 2.4 to 60.4 2" Aluminum 7.80 (17.1) 80 (176) 55 (800) 25.3 1.7 to 39.0 2" Al w/150# flange 9.10 (20.1) 80 (176) Flange Rule 25.3 1.7 to 39.0
F-X
FPD1000D-TX remote 4 to 20 mA output with programmable display (loop powered), shown smaller than actual size.
F
-
This graph is intended as an aid to determine the pressure drop of the measuring device as part of a system, allowing engineers to calculate the most economical components for their systems, i.e. pump selection would be determined on the total system pressure drop; the lower the pressure drop, the lower the cost of the pumping components. The graph above represents the pressure drop for standard and high-viscosity (special cut) rotors at various viscosities. Viscosities are in centipoise and the pressure drop is in psi and bar. As will be noted, the maximum pressure drop is shown at 14.5 psi (1 bar); although this is achievable, it is not recommended. The % of maximum flow rate represents the flow rate of any given meter model and can be applied to the above graph, i.e. 10% of the FPD-1005 model would be 3.2 gallons (12 liters).
F-X
Loading...