Omega Products FPD1001 Installation Manual

FPD1001 thru FPD1003,
FPD1102 and FPD1103,
FPD1201 thru FPD1203
SERIES LOW FLOW
Positive Displacement Flowmeters
(includes -R Option)
To the owner:
Red - Supply
Green - Ground
Blue - Output
X
V
cc
1 2 3
Please take a few minutes to read through the manual before installing and operating your meter. Always retain this manual for future reference. If you have any problems with the meter, refer to the Maintenance and Troubleshooting sections of the manual.
This manual contains connection and op­erating instructions for the OMEGA FPD Series meters. This includes the following models:
FPD1001 FPD1202-IP FPD1201 FPD1003 FPD1201-IP FPD1203 FPD1002 FPD1103 FPD1202 FPD1203-IP FPD1102
Part breakdowns for each model are locat­ed at the back of this manual. For models with displays and/or 4-20 mA output, an additional instruction manual is provided.
The flowmeter has incorporated the oval ro­tor principal into its design. This has proven to be a reliable and highly accurate method of measuring flow. Exceptional repeatability and high accuracy over a wide range of fluid viscosities and flowrates are features of the oval rotor design. With low pressure drop and high pressure rating, oval rotor flowmeters are suitable for both gravity and pump (in-line) applications.
OPERATION
Please read this information
!
carefully before use!
Before use, confirm the fluid to be used is compatible with the meter. Refer to Industry fluid compatibility charts or consult your local representative for advice.
To prevent damage from dirt or foreign matter it is recommended that a Y or bas­ket type 200 mesh strainer be installed as close as possible to the inlet side of the meter. Contact your local representative for advice.
NOTE: To prevent damage to the meter,
slowly fill the system with fluid (this will prevent damage caused by air purge). Failure to do this could damage the meter.
To reduce pressure build up, turn off the pump at the end of each day.
INSTALLATION
1. Use thread sealant on all pipe threads.
2. Ensure the meter is installed so that rotor shafts are always in a horizontal plane. Flow is bi-directional.
3. OMEGA recommends use of flexible connections.
4. Extreme care must be taken when installing the meter. Pipe strain or overtightening the meter connections can cause meter damage.
PULSER DETAILS
Hall Effect Sensor Specifications:
4.5V to 24V (4.6 ~ 9 mA) operation needs only an unregulated supply.
Open collector 25 mA output NPN
compatible with digital logic.
Reverse battery protection.
Figure 1
Hall Effect Sensor Wiring Details
1
Reed Relay Specifications:
Two wire SPST N/O.
Switching voltage: 150 VDC; Maximum
current: 0.25 AMPS.
Rating 3 watts.
MAINTENANCE
Disassembly:
1. Ensure the fluid supply to the meter has been disconnected, and the line pressure has been released before disassembly.
2. Remove four (4) screws and remove the meter body cover.
3. Remove O-ring and inspect. Replace O-ring if damaged.
4. Remove rotors, clean and inspect. Replace rotors if damaged.
Reassembly:
1. Place rotors into the meter body. The rotors should be at 90 degrees to each other.
NOTE: The rotor with magnets must be
placed in the body on the same side as the groove on the body. (Refer to diagram.)
2. Lightly rotate the rotors by hand. (They must rotate freely.)
3. Install O-ring.
4. Replace the meter cap.
NOTE: The groove on the cover must line
up with the groove on the meter body. (Refer to diagram.)
5. Replace the four screws.
! ! ! CA U T I ON !
!
Care must be taken not to overtighten the screws, or damage may occur.
2