Omega Products FDT101-DIN User Manual

IN-LINE ULTRASONIC FLOWMETER
FDT100 Series
Starts at
$
2538
Standard
Economical
Ultrasonic Flowmeter for Water Service
Battery PoweredDisplays Flow Rate
and Total
Extended Low
Flow Range
Virtually No
Pressure Loss
No Moving Parts for
Long Life
NIST 3-Point
Calibration Included
The FDT100 Series comprises advanced-technology water flowmeters. This series uses transit-time ultrasonic technology in which the signal is transmitted and received alternately between 2 flow sensors and the “time of flight” determines the flow rate. The battery-powered transmitter comes in the user’s choice of an integrally mounted display or a remote-mount version. Applications include both commercial and consumable water measurement. Long-term stability and a wide measurement range make it possible not only to measure water consumption, but also to monitor systems for water leakage. Because the FDT100 Series has no moving parts, system pressure loss is minimal and filtration is not required. Display flow rate or total at the push of a button. Installation is aided by 150-lb ANSI flanges in sizes from 2 to 8".
SPECIFICATIONS
Accuracy: ±2% of reading;
±5% below minimum transition rate
Fluid Temperature:
0 to 50°C (32 to 122°F)
Maximum Pressure: 230 psig Enclosure:
IP67 (integral mount version)
Electronic Housing:
Aluminum alloy with plastic cover
Display:
7-segment, 8-digit, single-line LCD
ANSI Flange Size 221⁄2 34568 Overload Flow Rate qs[GPM] 130 220 350 530 880 1320 1585 Nominal Flow Rate qp[GPM] 65 110 175 265 440 660 1100 Transitional Flow Rate qt[GPM] 13 22 35 53 88 132 220 Minimum Flow Rate q Pulse Output Constant k
DIN Flange Size Overload Flow
Rate qs[m3/h] Nominal Flow
Rate qp[m3/h] Transitional Flow
Rate qt[m3/h] Minimum Flow
Rate q
min
Pulse Output
Constant ki[l/pulse]
FDT103, $2538, shown smaller than actual size.
min
32 40 50 65 80 100 125 150 200
12 20 30 50 80 120 200 300 360
0.48 0.8 35812 20 30 50
[m3/h]
0.12 0.2 0.45 0.75 1.2 1.8 3 4.5 7.5
10 25 25 50 50 100 100 100 100
E-X
Remote display shown smaller than actual size
Current Output: 4 to 20 mA/DC current
(requires 8 to 24 Vdc supply)
Open Collector Output:
5 to 30 Vdc, 1 mA max
Flange: ANSI 150# or DIN Meter Body: Cast iron Power Supply:
Internal 3.6V battery (included), 1 to 2 year life
ANSI Size Rate Information
[GPM] 2 3.3 5.3 8 13.2 20 33
[gal/pulse] 5 10 10 15 30 30 30
i
DIN Size Rate Information
6 10 15 25 40 60 100 150 250
ULTRASONIC
SENSOR
ELECTRONIC CONTROL UNIT
PRESSURE
CURRENT OUTPUT
IMPULSE OUTPUT CONST.
warranty removed
void if
G/imp
ANSI
S/N 22686/06
BN 15 1,45psi
mA
psi
232 5
4-20
2"
136 (5.4)
S
L
D
DN
warranty removed
void if
G/imp
ANSI
S/N 226 86 /06
BN 15 1,45psi
mA
psi
232 5
4-20
2"
D
max length: 5 m (16.4')
ELECTRONIC SENSOR
ULTRASONIC
SENSOR
TERMINAL BOARD
PRESSURE
CURRENT OUTPUT
IMPULSE OUTPUT CONST.
DN
61 (2.4)
5.5 (0.2)
4 (0.2)
90 (3.5)
80 (3)
10 (0.4)
61 (2.4)
136
(5.4)
84
(3.3)
11 (0.4)
61 (2.4)
LL
Dimensions: mm (in)
ø = diameter
Compact Version—Basic Dimensions
DN 32 (13⁄4) 40 (11⁄2) 50 (2) 65 (21.2) 80 (3) 100 (4) 125 (5) 150 (6) 200 (8) L: mm (in) 260 (10.2) 300 (11.8) 300 (11.8) 300 (11.8) 350 (13.8) 350 (13.8) 350 (13.8) 350 (13.8) 350 (13.8) S: mm (in) 190 (7.5) 198 (7.8) 208 (8.2) 225 (8.9) 237 (9.3) 253 (10) 280 (11) 307 (12) 352 (14) D: mm (in) 140 (5.5) 150 (5.9) 165 (6.5) 185 (7.3) 200 (7.9) 220 (8.7) 250 (9.8) 285 (11.2) 340 (13.4) Weight: kg (lb) 4.5 (10) 7 (15) 10 (22) 11 (24) 15 (33) 17.5 (39) 22.5 (50) 26 (57) 36.5 (80)
E
Dimensions: mm (in)
ø = diameter
Remote Version—Basic Dimensions
DN 32 (13⁄4) 40 (11⁄2) 50 (2) 65 (21.2) 80 (3) 100 (4) 125 (5) 150 (6) 200 (8) L: mm (in) 260 (10.2) 300 (11.8) 300 (11.8) 300 (11.8) 350 (13.8) 350 (13.8) 350 (13.8) 350 (13.8) 350 (13.8) D: mm (in) 140 (5.5) 150 (5.9) 165 (6.5) 185 (7.3) 200 (7.9) 220 (8.7) 250 (9.8) 285 (11.2) 340 (13.4) Weight: kg (lb) 5 (11) 7.5 (16.5) 10.5 (23) 11.5 (25) 15.5 (34) 18 (40) 23 (51) 26.5 (58) 37 (82)
E-X