Omega Products FD-7000-M User Manual

VERSATILE MULTI-LIQUID ULTRASONIC FLOWMETERS
Enhanced Doppler Design
FD-7000
Standard
FD-7000 shown smaller than actual size.
Complete with portable electronics, transducer
set, acoustic couplant (not
shown), mounting straps,
power cord and battery
(not shown)
U Non-Invasive Design,
Easy to Install, No System Downtime
U Powered by
Rechargeable Internal Battery (Included) or AC Line Power
Semi-Clean Liquids, Emulsions and Slurries
U Digital Flowrate Indicator
Plus 8-Digit Totalizer
U 4 to 20 mA
Output Standard
U Easy-to-Use Data
Entry Keypad
U NEMA-4X ABS
Waterproof Enclosure
U NIST Certificate Standard
Up to now, doppler ultrasonic flowmeters have required significant quantities of suspended particles or gas bubbles to reflect sound signals. Now, with the model FD-7000 ultrasonic flowmeter, this is no longer required. When the FD-7000 is used to measure the flow of liquids containing suspended solids or bubbles, the transducers are mounted on a straight run of pipe in the same manner as other ultrasonic meters. In applications where insufficient “reflectors” exist (a condition indicated by a low reading on the FD-7000’s flow analyzer bar graph), the transducers are relocated to a point in the piping where non-symmetrical hydraulic turbulence will be present—ideally just downstream of a 90° elbow. The FD-7000’s unique digital filtering system and signal recognition circuitry transforms the reflections from this non­symmetrical, and not necessarily linear, turbulence into a useable and linear data format.
A backlit, 2 line by 20 character, alphanumeric LCD offers simultaneous flowrate and totalizer displays. The FD-7000 is designed for ease of use in the field. Only a few simple keypad entries are required to con­figure the flowmeter for any given pipe and flow conditions. The encapsulated, submersible design of the transducer sensor head allows it to be easily mounted to the pipe surface with the coupling compound and elastic bands that are supplied with the unit. A 6 m (20') retractable cable for connection to the transmitter/ indicator unit is supplied as as integral part of the sensor. The FD-7000 sensor is utilized on pipes that range in internal diameter from 25 mm to 1.5 m (1 to 60").
Flowrates can be measured in smaller pipes from 6 to 25 mm ( diameter with use of the small pipe sensor, model FD-7000-S1.
1
4 to 1") in
E-13
E
SPECIFICATIONS
System Accuracy: ±2% of FS Velocity Range: 0.15 to 6.2 MPS
(0.5 to 20 FPS)
Measuring Units: FPS, GPM, MGD Linearity: ±0.2% FS Repeatability: 0.4% of FS Flow Rate Display: 6-digit LCD
FD-7000-STD,
replacement sensor
for line sizes
25 to 1524 mm
(1 to 60") shown
smaller than actual size.
Required pipe mounting configuration.
Non-penetrating— easy installation.
Totalizer Display: 6-digit LCD
(resettable) Outputs: 4 to 20 mA into 600 Ω max., isolated Power Requirements: 115 Vac ±10%, 50/60 Hz, 20 VA max. (standard); 230 Vac 50/60 Hz (optional). Internal gel cell battery provides 8 hrs. of continuous operation Liquid Requirements: Full-pipe, low-viscosity (water-like) liquid
Transmitter/Indicator Operating Temperature: -30 to 70°C (-22 to 158°F) Sensor Operating Temperature:
-40 to 121°C (-40 to 250°F) Dimensions: 432 L x 279 W x 203 mm H (17 x 11 x 8")
Weight: 10 kg (22 lb) Enclosure: NEMA-4X (IP65)
To Order Visit omega.com/fd7000 for Pricing and Details
Model No. Description
FD-7000 Ultrasonic flowmeter, FPS, GPM, MGD (English) units FD-7000-M Ultrasonic flowmeter, MPS, LPM, m
Accessories
Model No. Description
FD-7000-STD Replacement sensor for 25 mm to 1.5 m (1 to 60") pipes FD-7000-S1 Sensors for 6 to 25 mm (¹⁄₄ to 1") pipe FD-7000-HT High temperature sensor for 25 mm to 1.5 m (1 to 60") pipe,
FD-7000-BATT Replacement gel cell battery FD-7000-Charger Replacement charging cord (USA) FD-7000-Charger-G Replacement charging cord (Germany)
FD-7000-Charger-UK
FD-7000-EXT Extension cable, 2 conductors, 20 AWG, unshielded,
For 230 Vac version add suffix “-230” to model number, no additional cost. Comes complete with operator’s manual, 2 transducers, couplant, power cord, NIST certificate and gel cell battery.
Ordering Example: FD-7000, ultrasonic flowmeter.
204°C (400°F)
Replacement charging cord (UK)
6 m (20')
E-14
3/hr (metric) units