EZ I/O
EZI/O System supports two High Speed 24 bit Counter
Modules with PLS outputs that accept quadrature encoder
inputs. The PLS outputs compare the counter value to two
on/off presets and turn on outputs within 100µs of position
change. Presets can be loaded into the counter modules
from EZPLC. All inputs and outputs are optically isolated.
In addition, PLS outputs are 0.5A short circuit proof DC
outputs.
The counters have various preset/reset and inhibit modes as
shown on the following page.
High Speed Counter Modules
Confi guring your High Speed
Counter Module is EZier than Ever!
In EZPLC’s
1
I/O
confi guration
specify the
range of
registers to
be used for
input and
output.
with PLS Outputs
2 Counter Pin Out
Pin
EZIO-HSCM1
(dual counter)
No.
1 Quad A encoder 1
2 Quad B encoder 1
3 Quad A encoder 2
4 Quad B encoder 2
5 Common
6 Preset
7 Counter 1 Output 1
8 Counter 1 Output 2
9 Counter 2 Output 1
10 Counter 2 Output 2
11 Vs+
Delivery
Code
3DAY
1 Counter Pin Out
Pin
EZIO-HSCM2
(single counter)
No.
1 Quad A encoder 1
2 Quad B encoder 1
3 Inhibit
4 Reset
5 Common
6 Preset
7 Counter 1 Output 1
8 Counter 1 Output 2
9 Counter 1 Output 3
10 Counter 1 Output 4
11 Vs+
Confi gure pulse, direction,
2
quadrature counting, set points,
preset values and preset mode
Detailed information for
3
input and output registers
EZ I/O
TM
High Speed Counter Module
Specifi cations
Module Specifi cations
Feature
Module Type
Maximum Input
Frequency
Minimum Pulse
Width
Resource Options
Counter Range
Preset Modes
Reset Modes/Input
Inhibit Input
EZIO-HSCM1 (dual) EZIO-HSCM2 (single)
Intelligent High Speed
Dual Counter Module
100KHz after 1X, 2X or 4X
Multiplication
1X, 2X, or 4X Quadrature, Up or Down Counter, Reset
1. This mode will preset the counter to the preset value while
preset is held high. While the preset signal is high, no new
count signals will be counted.
2. This mode will create an interrupt on the rising edge of the
reset signal to set the counter to the preset value.
3. This mode will create an interrupt on the falling edge of the
preset signal to set the counter to the preset value.
4. This mode will create a preset pulse every time that there is a
rising edge of signal A and the preset signal is high.
None Same as Preset except the
None Inhibits the counter from
PLS Output Specifi cations
Feature
Number of
Outputs
Response Time 100µs
PLS Setpoints 1 on/off pair for each output
Peak Voltage 50.0 VDC
Maximum Steady
State Output
Current
Maximum
Leakage Current
ON Voltage Drop 2 VDC @ 0.5A
Maximum Inrush
Current
OFF to ON
Response
ON to OFF
Response
Status Indicators Red LED for each output
+V Terminals
& Commons
Short Circuit
Protection
Optical Isolation 2500 Volt
EZIO-HSCM1
(dual counter)
2 Source
outputs for
each counter
1.0A max per module @ 50°C
100µA @ 50 VDC @ 50°C
One V
1 Amp per module, turns off
outputs upon short circuit
EZIO-HSCM2
(single counter)
4 Source
outputs
0.5A per output,
0.8A for 10ms
< 2µs
<10µs
+
, 1 Common
detection
Intelligent High Speed
Single Counter Module
60KHz after 1X, 2X or 4X
Multiplication
5 µs
16 million (24 bits)
reset input sets the counter
value to zero
counting when high
Counter Input Specifi cations
Feature
Number of
Inputs
Input Voltage
Range
Peak Voltage 40 VDC
Input Current
Maximum Input
Current
Input Impedance 5.6KΩ min. @ 14-28 VDC
ON Voltage
Level
OFF Voltage
Level
Min. ON Current 2.5 mA
Min. OFF Current
OFF to ON
Response
ON to OFF
Response
Status Indicators
Commons 1 point
EZIO-HSCM1
(dual counter)
2.5 mA @ 14 VDC
5.0 mA @ 28 VDC
Red LED for each input
(14-28 VDC)
EZIO-HSCM2
(single counter)
5
14-28 VDC
5 mA @ 28 VDC
> 14 VDC
< 2 VDC
0.2 mA
< 2µs
< 3µs
General Specifi cations
Optical Isolation 2500 Volt
Wires
Operating
Environment
DC INPUT (Source)
for Control Signals
(External)
Encoder
Output
DC INPUT (Source)
for Control Signals
1 of 14 AWG, 2 of 18 AWG,
4 of 22 AWG
0-60°C, Humidity non-condensing 5-95%
(Internal)
(10-28 VDC)
(14-28 VDC)