Omega Products EZ202-RE, EZ-M-256K User Manual

EZ SEriES intElligEnt rElayS
EZ Series
EZ820-DC-RC shown
Easy Operation with Maximum Benefits
The Eaton EZ intelligent relays provide basic functions that users could only implement previously with individually installed and wired devices. The EZD multi-function displays offer powerful visualization functions.
The EZ intelligent relays bring timers, relays, counters, special functions, inputs and outputs into one compact device that is easily configured. The EZ family of products provides exceptional levels of flexibility together with substantial savings in commissioning time and effort.
The EZ intelligent relays are available in more than 20 different styles that support from 12 I/O up to 320 I/O points providing the ideal solution for lighting, energy management, industrial control, watering, pump control, HVAC and home automation.
Once EZ products are installed, changes are easily accomplished through front panel programming, eliminating the need to change wiring and wiring diagrams increasing the savings realized.
Other terms often used for intelligent relay are relay replacer, control relay and smart relay.
Simplicity and User-Friendly Operation
EZ and EZD products are known for their user-friendly operation and programming. Every rung or circuit connection is wired just like you remember: Contact – Contact – Contact – Coil – Done! The devices allow the “wiring” of 128 or 256 rungs or circuit connections. Series and parallel connections, which make up a major part of a control circuit, are easily created without previous programming knowledge. Ready-to-use function blocks are simply integrated in the wiring with coils, and contacts are provided for additional functions.
smaller than actual size.
EZ512-DC-RC
shown smaller
A
Programmable Logic Controllers
EZ719-DC-RC shown smaller than actual size.
EZD-80-B shown smaller than actual size.
A-18
Everything Needed is Built-In
Depending on the device selected, EZ and EZD products provide users with timing relays, flash relays, counters, comparators, timer switches and other ready-to-use functions. The circuit diagram display of serial and parallel connections, unlike
EZ500 Series
EZ500 Series— for controlling
small applications with up to 12 input/output signals. Models are available with and without displays. DIN rail mounted.
l 8 Digital Inputs l 4 Digital Inputs l 128 Rungs of 3 Contacts
and 1 Coil Each
l 16 Operating and
Message Texts
l 2 Analog Inputs (10-Bit)
Optional (Not with 240 Vac)
l 2 High-Speed Inputs,
1 kHz (Only DC Devices)
the display of AND and OR operations in a function block diagram, offers a more manageable display of the circuit. Every EZ and EZD intelligent relay features an integrated power flow display to ensure safe operation during commissioning and helps identify errors in the circuit diagram. For ease-of-use, energized rungs are highlighted, and non-energized rungs are dimmed.
EZ512-AC-RC shown
smaller than actual size.
Security Means Safety
The finished circuit diagram is stored internally and can also be saved externally on a memory module (EEPROM) for transport, security and backup. Multi-level password protection secures your circuit diagram from unauthorized viewing, editing, copying or deleting.
EZ512-DC-RC shown smaller than actual size.
EZ700 Series— for controlling medium-
sized applications with up to 40 input/output signals. DIN rail mounted.
EZ719-DC-RC shown smaller than actual size.
l 12 Digital Inputs l 6 Digital Relay Outputs l 128 Rungs of 3 Contacts and
1 Coil Each
l 16 Operating and Message Texts l 4 Analog Inputs (10-Bit) Optional
(Not with 230 Vac)
l 2 High-Speed Inputs, 1 kHz
(Only DC Devices)
l 1 Digital Expansion or
Network Connection
INPUTS OUTPUTS
24 110 to 12 24 MODEL NO. DESCRIPTION Vac 240 Vac Vdc Vdc ANALOG RELAY
EZ719-AC-RC 18 I/O, clock, display 12 6 EZ719-AC-RCX 18 I/O, clock, no display 12 6
EZ719-DC-RC 18 I/O, clock, display 12 4 6 EZ719-DC-RCX 18 I/O, clock, no display 12 4 6
Comes complete with installation guide. Ordering Example: EZ719-AC-RCX, 18 I/O, clock, no display.
EZ700 Series
EZ719-AC-RCX
shown smaller
EZ800 Series
l
4 High-Speed Inputs,
EZ800 Series—
applications with up to 320 input/ output signals. Models are available with and without displays. DIN rail mounted.
for controlling large scale
l 12 Digital Inputs l 6 Digital Relay Outputs l 256 Rungs of 4 Contacts and
1 Coil Each
l 32 Operating and Message Texts l 4 Analog Inputs (10-Bit)
Optional (Not with 230 Vac)
3/5 kHz (Only DC Devices)
l 1 Digital Expansion or
Network Connection
l Networkable via EZ-NET
with Up to 8 Stations
l 1 Analog Output (10 bit)
EZ819-AC-RC shown smaller
A
Programmable Logic Controllers
To Order Visit omega.com/ezser_intrelays for Pricing and Details
INPUTS OUTPUTS
24 110 to 12 24 MODEL NO. DESCRIPTION Vac 240 Vac Vdc Vdc ANALOG RELAY
EZ512-AC-R 12 I/O, no clock, display 8 4 EZ512-AC-RC 12 I/O, clock, display 8 4 EZ512-AC-RCX 12 I/O, clock, no display 8 4 EZ512-DC-R 12 I/O, no clock, display 8 2 4 EZ512-DC-RC 12 I/O, clock, display 8 2 4 EZ512-DC-RCX 12 I/O, clock, no display 8 2 4
Comes complete with installation guide. Ordering Example: EZ512-AC-RCX, 12 I/O, clock, no display.
To Order Visit omega.com/ezser_intrelays for Pricing and Details
INPUTS OUTPUTS
110 to 24 MODEL NO. DESCRIPTION 240 Vac Vdc ANALOG RELAY ANALOG
EZ819-AC-RC 18 I/O, clock, display 12 6 EZ819-AC-RCX 18 I/O, clock, no display 12 6 EZ819-DC-RC 18 I/O, clock, display 12 4 6 EZ819-DC-RCX 18 I/O, clock, no display 12 4 6 EZ820-DC-RC 19 I/O, clock, display 12 4 6 1 EZ820-DC-RCX 19 I/O, clock, no display 12 4 6 1
Comes complete with installation guide. Ordering Example: EZ819-DC-RCX, 18 I/O, clock, no display.