Omega Products EP510-0120 User Manual

L-11
Starts at
$
510
Hazardous Location
and Intrinsically Safe Ratings
Feedback Control
Built-In Volume Booster
Provides Flow Up to 12 SCFM
Easy Access to Zero
and Span
Damping Pot Prevents
Overshoot and Hunting
Low Air ConsumptionMount at Any AngleCompact and
Lightweight
Virtually No Sensitivity
to Supply Pressure Changes
Removable Orifice for
Easy Maintenance
Buna-N Seals StandardFluorocarbon Seals
Optional
The IP510/EP510 Series is a patented family of electro­pneumatic instruments used to reduce a supply pressure to a regulated output pressure that is
Repeatability:
Typical: ±0.01% of output span Maximum: ±0.10% of output span
Ambient Temperature Effect:
Typical: ±0.004% of nominal span
per ºF Maximum: ±0.022% of nominal span per ºF
Span:
Typical: 0.013% of
calibrated span per ºF Maximum: 0.022% of calibrated span per ºF
Temperature Effect:
0.02%/ºF, zero and span effects combined
directly proportional to a 2-wire current or 3-wire voltage input. This design incorporates closed­loop sensing of the output pressure to achieve excellent accuracy and vibration stability. It also features a unique damping circuit that can be adjusted to prevent overshoot and actuator “hunting.” Model selection includes general purpose NEMA 1 (IP00) and watertight/corrosion­resistant NEMA 4X (IP66). All models carry hazardous location and intrinsically safe ratings.
SPECIFICATIONS
Accuracy:
Typical: ±0.1% of output span Maximum: ±0.25% of output span
Hysteresis:
Typical: ±0.01% of output span Maximum: ±0.10% of output span
Deadband: No effect
IP510 Series
Current to Pressure (I/P) and Voltage to Pressure (E/P) Models
EP511-X30, $695, shown smaller than actual size.
IP510-X27, $510, shown smaller than actual size.
HEAVY-DUTY ELECTROPNEUMATIC CONVERTERS
FM
APPROVED
L
VALVES AND REGULATORS
HEAVY-DUTY ELECTROPNEUMATIC CONVERTERS
Comes complete with operator’s manual
Note: To order fluorocarbon seals, add suffix “-F” to model numbers and add $10 to price. Ordering Example: IP511-X30, electropneumatic converter, 4 to 20 mA input/6 to 30 psi
output with NEMA 4X (IP66) enclosure, TX4-100, 4-conductor shielded cable,$695 + 35 = $730.
Operating Temperature Range:
Buna-N Elastomers:
-29 to 71°C (-20 to 160°F)
Fluorocarbon Elastomers:
-18 to 71°C (0 to 160°F)
Storage Temperature:
Buna-N Elastomers:
-40 to 93°C (-40 to 200°F)
Fluorocarbon Elastomers:
-26 to 93°C (-15 to 200°F)
Vibration Effects: Less than
0.5% of span per 1 g 5 to 2000 Hz, 3 g maximum, 3 axes
Mounting Position Effect:
Not measurable
Loop Load, I/P Transducer:
Less than 10 Vdc drop at 20 mA Less than 10 Vdc drop at 50 mA
Supply Voltage, E/P Transducer:
Intrinsically Safe/Non-Incendive:
9 to 28 Vdc, less than 20 mA General Purpose: 9 to 40 Vdc, less than 20 mA
Supply Voltage Effect: No effect Signal Impedance E/P Transducer:
6000 minimum
RFI/EMI Effect NEMA 4X (IP66):
Less than 0.25% of span change in output 10 V/meter, 20 to 1000 MHz (Reference SAMA PML 33.1 to 1978, 2 to abc)
Supply Pressure Sensitivity: No effect Effective Air Consumption:
0.07 SCFM (2 LPM) maximum
Supply Pressure:
100 psig (6.9 bar) maximum
Port Sizes:
Pneumatic:1⁄4 FNPT Electrical:1⁄2 FNPT
Agency Approvals—All 510 and
511 electropneumatic converters are approved by FM and CSA as intrinsincally safe Class I, Division 1, Groups A, B, C, D hazardous locations.
The 511 (NEMA 4X) models are also approved for FM and CSA explosion-proof service: Class I, Division 1 and 2, Groups B, C, D. Dust ignition-proof service: Class II, Division 1 and 2, Groups E, F, G.
NEMA 4X units are also suitable for Class III, Division 1 and 2.
Warning: These ratings are valid ONLY WHEN the cover is fully installed and the electrical connections conform to required standards.
MODEL NO. PRICE DESCRIPTION
TX4-100 $35 4-conductor shielded wire
ACCESSORY
To Order
(Specify Model Number)
MODEL NO. PRICE INPUT RANGE OUTPUT RANGE NEMA 1 (IP00) ENCLOSURE
IP510-X15 $510 4 to 20 mA 3 to 15 psig IP510-X27 510 4 to 20 mA 3 to 27 psig IP510-X30 510 4 to 20 mA 6 to 30 psig IP510-060 530 4 to 20 mA 0 to 60 psig IP510-0120 530 4 to 20 mA 0 to 120 psig EP510-X15 510 1 to 5 Vdc 3 to 15 psig EP510-X27 510 1 to 5 Vdc 3 to 27 psig EP510-X30 510 1 to 5 Vdc 6 to 30 psig EP510-060 530 1 to 5 Vdc 0 to 60 psig EP510-0120 530 1 to 5 Vdc 0 to 120 psig
NEMA 4X (IP66) ENCLOSURE
IP511-X15 $695 4 to 20 mA 3 to 15 psig IP511-X27 695 4 to 20 mA 3 to 27 psig IP511-X30 695 4 to 20 mA 6 to 30 psig IP511-060 725 4 to 20 mA 0 to 60 psig IP511-0120 725 4 to 20 mA 0 to 120 psig EP511-X15 695 1 to 5 Vdc 3 to 15 psig EP511-X27 695 1 to 5 Vdc 3 to 27 psig EP511-X30 695 1 to 5 Vdc 6 to 30 psig EP511-060 725 1 to 5 Vdc 0 to 60 psig EP511-0120 725 1 to 5 Vdc 0 to 120 psig
MOST POPULAR MODELS HIGHLIGHTED!
L-12
ENTITY PARAMETERS
V
max
= 30 Vdc, I
max
= 100 mA, Ci= 0 µF, Li= 0 mH T4 Max. Ambient 70°C. Vocand Iscof a barrier shall not exceed V
max
and I
max
of the transducer.
(Li + wiring) and (Ci+ C
wiring
) shall not exceed Laand Caof a barrier. A barrier is not necessary when the transducer is in any of these locations.
Recommended Reference Book:
Measure for Measure,
OP-17, $15
See Section Y For Additional Books
SPAN POTENTIOMETER
ZERO POTENTIOMETER
DAMPING POTENTIOMETER
TERMINAL BLOCK
GROUND SCREW
1
2 NPT
ELECTRICAL PORT
COIL
COIL WIRE CONNECTOR
REMOVABLE
ORIFICE
1
8 NPT
GAUGE PORT
1
4 NPT SUPPLY
PRESSURE PORT
Loading...