MOUNTING
BRACKET
1/2-14 NPT
35.1
(1.38)
38.6
(1.52)
27.9
(1.10)
14.0
(0.55)
5.3
(0.21) DIA
107.7
(4.24)
28.4
(1.12)
35.3
(1.39)
14.0
(0.55)
ALTERNATE OUTPUT/
GAUGE PORT
2 LEADS
#18 GA. WIRE
18” LONG (EA.)
1 BLACK (+)
1 WHITE (-)
38.1
#10-32 UNF-2A
X.38 DP . (2)
MOUNTING HOLES
28.7
(1.13)
Y
Z
X
30.2
SIGNAL
1/4
-18 NPT
(
4
PLACES)
SUPPLY
ALTERNATE OUTPUT/
GAUGE PORT
OUTPUT
REMOVABLE
ORIFICE
MAX (Square)
55.4
73.1
SPAN
ZERO
(1.19)
(2.88)
(2.18)
(1.50)
GENERAL PURPOSE
ELECTROPNEUMATIC TRANSDUCERS
I/P AND E/P MODELS
IP211 Current to Pressure (I/P)
EP211 Voltage to Pressure (E/P)
Starts at
$
Optional
†
ptional
O
†
285
IP211-X15, $285,
shown actual size
⻬ Low Cost
⻬ Built-In Volume Booster
⻬ Small Size
⻬ Field Reversible
⻬ Low Air Consumption
⻬ Mounts at Any Angle
⻬ Convenient External Span and
Zero Adjustment (Except for
Explosion-Proof Models)
⻬ Light Weight
⻬ Wide Supply Pressure Range
⻬ Low Supply Pressure
Sensitivity
The IP211/EP211 Series
transducers are electropneumatic
devices that reduce a supply pressure
to a regulated output pressure directly
proportional to an electrical input
signal. The 211 Series accepts a wide range
of supply pressures, ranging from a minimum
of 3 psig (0.2 bar) above the maximum output to
100 psig (6.9 bar). An integral pneumatic volume
booster is included in the design to provide high flow
capacity (up to 12 SCFM). Model selection includes
general purpose, FM Intrinsically Safe, and CSA
Intrinsically Safe.
Mounting
These transducers can be pipe, panel, or bracket
mounted in any position. Positions
other than vertical will require
recalibration of the zero adjustment.
For maximum output stability, the
transducers should be mounted in a
vibration- free location or where
vibration is isolated in the x and
z axes.
Field Reversible
All transducers are calibrated at the
factory for direct-acting operation
but may be used in the reverseacting mode by reversing the
polarity of the signal leads and
recalibrating. When recalibrated
(mounting bracket
included).
for reverse-acting applications, the
transducers provide a minimum of
their full rated output pressure
(i.e.,15, 27, or 30 psig) upon input
signal failure.
†
for specific FM or CSA approved models.
L-5
Refer to the To Order Chart on page L-6
Dimensions:
mm (in)
Easily
accessible
zero and
span
adjustments

GENERAL PURPOSE
ELECTROPNEUMATIC TRANSDUCERS
SPECIFICATIONS
Supply Pressure Range:
psig (0.2 bar) above maximum output
3
to 120 psig
15 psig (1 bar) units: 18 to 100 psig
(1.3 to 7 bar)
27 psig (1.9 bar) units: 30 to 100 psig
(1.9 to 7 bar)
30 psig (2.1 bar) units: 33 to 100 psig
(2.3 to 7 bar)
60 psig (4.1 bar) units: 65 to 100 psig
(4.5 to 7 bar)
120 psig (8.3 bar) units: 125 to 150 psig
(8.6 to 10.4 bar)
Supply Pressure Sensitivity:
±0.15 of span 1.5 psig (0.1 bar)
Linearity (Terminal Based):
<1.0% of span
Repeatability: <0.5% of span
Hysteresis: <1.0% of span
Minimum Flow Rate @ 100 psig
(7 bar): 12 SCFM
To Order
MODEL NO. PRICE INPUT RANGE
GENERAL PURPOSE I/P
IP211-X15 $285 4 to 20 mA 3 to 15 0.2 to 1.0 180 Ω
IP211-X27 285 4 to 20 mA 3 to 27 0.2 to 1.9 220 Ω
IP211-X30 285 4 to 20 mA 6 to 30 0.4 to 2.1 220 Ω
IP211-X60 340 4 to 20 mA 2 to 60 0.1 to 4.1 225 Ω
IP211-X120 340 4 to 20 mA 3 to 120 0.2 to 8.3 260 Ω
FM APPROVED†INTRINSICALLY SAFE I/P
IP211-X15-ISF $327 4 to 20 mA 3 to 15 0.2 to 1.0 180 Ω
IP211-X27-ISF 327 4 to 20 mA 3 to 27 0.2 to 1.9 220 Ω
CSA APPROVED†INTRINSICALLY SAFE I/P
IP211-X15-ISC $327 4 to 20 mA 3 to 15 0.2 to 1.0 180 Ω
IP211-X27-ISC 327 4 to 20 mA 3 to 27 0.2 to 1.9 220 Ω
GENERAL PURPOSE E/P
EP211-X15 $285 1 to 5 Vdc 3 to 15 0.2 to 1.0 615 Ω
EP211-X15-5V 285 0 to 5 Vdc 3 to 15 0.2 to 1.0 615 Ω
EP211-X15-10V 285 0 to 10 Vdc 3 to 15 0.2 to 1.0 985 Ω
EP211-X27 285 1 to 5 Vdc 3 to 27 0.2 to 1.9 530 Ω
EP211-X27-5V 285 0 to 5 Vdc 3 to 27 0.2 to 1.9 530 Ω
EP211-X27-10V 285 0 to 10 Vdc 3 to 27 0.2 to 1.9 840 Ω
EP211-X30 285 1 to 5 Vdc 6 to 30 0.4 to 2.1 530 Ω
EP211-X30-5V 285 0 to 5 Vdc 6 to 30 0.4 to 2.1 530 Ω
EP211-X60-5V 340 0 to 5 Vdc 2 to 60 0.1 to 4.1 500 Ω
EP211-X120-10V 340 0 to 10 Vdc 3 to 120 0.2 to 8.3 805 Ω
ACCESSORY
TX4-100 $35 30.48 m (100') of 4-conductor shielded wire
Comes complete with operator’s manual and mounting bracket.
Ordering Example: IP211-X30, electropneumatic converter with 6 to 30 psig output, TX4-100, 4-conductor shielded wire,
$285 + 35 = $320.
(Specify Model Number)
Exhaust Capacity @ 5 psig
(0.4 bar) Above Setpoint
Air Consumption (Max)
at Midrange
Port Size (Pneumatic/Electric)
1
⁄4 NPT and 1⁄2 NPT
Dimensions
1
(2
⁄8 x 21⁄8 x 4")
Maximum Flow:
Agency Approvals:
Research Approved as Intrinsically
Safe for Class I, II, III, Division 1,
Groups A, B, C, D, E, G when installed
in accordance with interconnection
diagram and with the proper energy
limiting barriers. Canadian Standards
Association certified as intrinsically
safe when connected through certified
diode safty barriers in accordance with
installation instruction.
Note: Intrinsically safe and non-incendive
ratings are not affected by recalibrating for
split ranges or reverse-acting applications.
: 0.1 SCFM
: 54 x 54 x 101 mm
24 SCFM (677 SLPM)
: 2 SCFM
:
Factory Mutual
OUTPUT RANGE IMPEDANCE
psig bar
IP211-X15, $285, shown smaller
than actual size.
MOST POPULAR
MODELS HIGHLIGHTED!
(NOMINAL)
L-6
VALVES AND REGULATORS
L

One Omega Drive | Stamford, CT 06907 | 1-888-TC-OMEGA (1-888-826-6342) | info@omega.com
www.omega.com
UNITED KINGDOM
www. omega.co.uk
Manchester, England
0800-488-488
UNITED STATES
www.omega.com
1-800-TC-OMEGA
Stamford, CT.
CANADA
www.omega.ca
Laval(Quebec)
1-800-TC-OMEGA
GERMANY
www.omega.de
Deckenpfronn, Germany
0800-8266342
Karviná, Czech Republic
FRANCE
www.omega.fr
Guyancourt, France
088-466-342
CZECH REPUBLIC
www.omegaeng.cz
596-311-899
BENELUX
www.omega.nl
Amstelveen, NL
0800-099-33-44
More than 100,000 Products Available!
Temperature
Calibrators, Connectors, General Test and Measurement
Instruments, Glass Bulb Thermometers, Handheld Instruments
for Temperature Measurement, Ice Point References,
Indicating Labels, Crayons, Cements and Lacquers, Infrared
Temperature Measurement Instruments, Recorders Relative
Humidity Measurement Instruments, RTD Probes, Elements
and Assemblies, Temperature & Process Meters, Timers and
Counters, Temperature and Process Controllers and Power
Switching Devices, Thermistor Elements, Probes and
Assemblies,Thermocouples Thermowells and Head and Well
Assemblies, Transmitters, Wire
Flow and Level
Air Velocity Indicators, Doppler Flowmeters, Level
Measurement, Magnetic Flowmeters, Mass Flowmeters,
Pitot Tubes, Pumps, Rotameters, Turbine and Paddle Wheel
Flowmeters, Ultrasonic Flowmeters, Valves, Variable Area
Flowmeters, Vortex Shedding Flowmeters
pH and Conductivity
Conductivity Instrumentation, Dissolved Oxygen
Instrumentation, Environmental Instrumentation, pH
Electrodes and Instruments, Water and Soil Analysis
Instrumentation
Data Acquisition
Auto-Dialers and Alarm Monitoring Systems,
Communication Products and Converters, Data
Acquisition and Analysis Software, Data Loggers
Plug-in Cards, Signal Conditioners, USB, RS232, RS485
and Parallel Port Data Acquisition Systems, Wireless
Transmitters and Receivers
Pressure, Strain and Force
Displacement Transducers, Dynamic Measurement
Force Sensors, Instrumentation for Pressure and Strain
Measurements, Load Cells, Pressure Gauges, Pressure
Reference Section, Pressure Switches, Pressure Transducers,
Proximity Transducers, Regulators,
Strain Gages, Torque Transducers, Valves
Heaters
Band Heaters, Cartridge Heaters, Circulation Heaters,
Comfort Heaters, Controllers, Meters and Switching
Devices, Flexible Heaters, General Test and Measurement
Instruments, Heater Hook-up Wire, Heating Cable
Systems, Immersion Heaters, Process Air and Duct,
Heaters, Radiant Heaters, Strip Heaters, Tubular Heaters
click here to go to the omega.com home page