Omega Products EP211-X120-10V User Manual

Page 1
FM
APPROVED
MOUNTING BRACKET
1/2-14 NPT
35.1
(1.38)
38.6
(1.52)
27.9
(1.10)
14.0
(0.55)
5.3
(0.21) DIA
107.7 (4.24)
28.4
(1.12)
35.3
(1.39)
14.0 (0.55)
ALTERNATE OUTPUT/ GAUGE PORT
2 LEADS #18 GA. WIRE 18” LONG (EA.) 1 BLACK (+) 1 WHITE (-)
38.1
#10-32 UNF-2A X.38 DP . (2) MOUNTING HOLES
28.7
(1.13)
Y
Z
X
30.2 SIGNAL
1/4
-18 NPT
(
4
PLACES)
SUPPLY
ALTERNATE OUTPUT/ GAUGE PORT
OUTPUT
REMOVABLE ORIFICE
MAX (Square)
55.4
73.1
SPAN
ZERO
(1.19)
(2.88)
(2.18)
(1.50)
GENERAL PURPOSE ELECTROPNEUMATIC TRANSDUCERS
I/P AND E/P MODELS
IP211 Current to Pressure (I/P) EP211 Voltage to Pressure (E/P)
Starts at
$
Optional
ptional
O
285
IP211-X15, $285,
shown actual size
Low CostBuilt-In Volume BoosterSmall SizeField ReversibleLow Air ConsumptionMounts at Any AngleConvenient External Span and
Zero Adjustment (Except for Explosion-Proof Models)
Light WeightWide Supply Pressure RangeLow Supply Pressure
Sensitivity
The IP211/EP211 Series transducers are electropneumatic devices that reduce a supply pressure to a regulated output pressure directly proportional to an electrical input signal. The 211 Series accepts a wide range of supply pressures, ranging from a minimum of 3 psig (0.2 bar) above the maximum output to 100 psig (6.9 bar). An integral pneumatic volume booster is included in the design to provide high flow capacity (up to 12 SCFM). Model selection includes general purpose, FM Intrinsically Safe, and CSA Intrinsically Safe.
Mounting
These transducers can be pipe, panel, or bracket mounted in any position. Positions other than vertical will require recalibration of the zero adjustment. For maximum output stability, the transducers should be mounted in a vibration- free location or where vibration is isolated in the x and z axes.
Field Reversible
All transducers are calibrated at the factory for direct-acting operation but may be used in the reverse­acting mode by reversing the polarity of the signal leads and recalibrating. When recalibrated
(mounting bracket
included).
for reverse-acting applications, the transducers provide a minimum of their full rated output pressure (i.e.,15, 27, or 30 psig) upon input signal failure.
for specific FM or CSA approved models.
L-5
Refer to the To Order Chart on page L-6
Dimensions:
mm (in)
Easily accessible zero and span adjustments
Page 2
GENERAL PURPOSE ELECTROPNEUMATIC TRANSDUCERS
SPECIFICATIONS
Supply Pressure Range:
psig (0.2 bar) above maximum output
3 to 120 psig 15 psig (1 bar) units: 18 to 100 psig (1.3 to 7 bar) 27 psig (1.9 bar) units: 30 to 100 psig (1.9 to 7 bar) 30 psig (2.1 bar) units: 33 to 100 psig (2.3 to 7 bar) 60 psig (4.1 bar) units: 65 to 100 psig (4.5 to 7 bar) 120 psig (8.3 bar) units: 125 to 150 psig (8.6 to 10.4 bar)
Supply Pressure Sensitivity:
±0.15 of span 1.5 psig (0.1 bar)
Linearity (Terminal Based):
<1.0% of span
Repeatability: <0.5% of span Hysteresis: <1.0% of span Minimum Flow Rate @ 100 psig
(7 bar): 12 SCFM
To Order
MODEL NO. PRICE INPUT RANGE GENERAL PURPOSE I/P
IP211-X15 $285 4 to 20 mA 3 to 15 0.2 to 1.0 180 Ω IP211-X27 285 4 to 20 mA 3 to 27 0.2 to 1.9 220 Ω IP211-X30 285 4 to 20 mA 6 to 30 0.4 to 2.1 220 Ω IP211-X60 340 4 to 20 mA 2 to 60 0.1 to 4.1 225 Ω IP211-X120 340 4 to 20 mA 3 to 120 0.2 to 8.3 260 Ω
FM APPROVED†INTRINSICALLY SAFE I/P
IP211-X15-ISF $327 4 to 20 mA 3 to 15 0.2 to 1.0 180 Ω IP211-X27-ISF 327 4 to 20 mA 3 to 27 0.2 to 1.9 220 Ω
CSA APPROVED†INTRINSICALLY SAFE I/P
IP211-X15-ISC $327 4 to 20 mA 3 to 15 0.2 to 1.0 180 Ω IP211-X27-ISC 327 4 to 20 mA 3 to 27 0.2 to 1.9 220 Ω
GENERAL PURPOSE E/P
EP211-X15 $285 1 to 5 Vdc 3 to 15 0.2 to 1.0 615 Ω EP211-X15-5V 285 0 to 5 Vdc 3 to 15 0.2 to 1.0 615 Ω EP211-X15-10V 285 0 to 10 Vdc 3 to 15 0.2 to 1.0 985 Ω EP211-X27 285 1 to 5 Vdc 3 to 27 0.2 to 1.9 530 Ω EP211-X27-5V 285 0 to 5 Vdc 3 to 27 0.2 to 1.9 530 Ω EP211-X27-10V 285 0 to 10 Vdc 3 to 27 0.2 to 1.9 840 Ω EP211-X30 285 1 to 5 Vdc 6 to 30 0.4 to 2.1 530 Ω EP211-X30-5V 285 0 to 5 Vdc 6 to 30 0.4 to 2.1 530 Ω EP211-X60-5V 340 0 to 5 Vdc 2 to 60 0.1 to 4.1 500 Ω EP211-X120-10V 340 0 to 10 Vdc 3 to 120 0.2 to 8.3 805 Ω
ACCESSORY
TX4-100 $35 30.48 m (100') of 4-conductor shielded wire
Comes complete with operator’s manual and mounting bracket. Ordering Example: IP211-X30, electropneumatic converter with 6 to 30 psig output, TX4-100, 4-conductor shielded wire,
$285 + 35 = $320.
(Specify Model Number)
Exhaust Capacity @ 5 psig (0.4 bar) Above Setpoint
Air Consumption (Max) at Midrange
Port Size (Pneumatic/Electric)
1
4 NPT and 1⁄2 NPT
Dimensions
1
(2
8 x 21⁄8 x 4")
Maximum Flow: Agency Approvals:
Research Approved as Intrinsically Safe for Class I, II, III, Division 1, Groups A, B, C, D, E, G when installed in accordance with interconnection diagram and with the proper energy limiting barriers. Canadian Standards Association certified as intrinsically safe when connected through certified diode safty barriers in accordance with installation instruction.
Note: Intrinsically safe and non-incendive ratings are not affected by recalibrating for split ranges or reverse-acting applications.
: 0.1 SCFM
: 54 x 54 x 101 mm
24 SCFM (677 SLPM)
: 2 SCFM
:
Factory Mutual
OUTPUT RANGE IMPEDANCE
psig bar
IP211-X15, $285, shown smaller
than actual size.
MOST POPULAR
MODELS HIGHLIGHTED!
(NOMINAL)
L-6
VALVES AND REGULATORS
L
Page 3
One Omega Drive | Stamford, CT 06907 | 1-888-TC-OMEGA (1-888-826-6342) | info@omega.com
EPG05
www.omega.com
UNITED KINGDOM
www. omega.co.uk
Manchester, England
0800-488-488
UNITED STATES
www.omega.com
1-800-TC-OMEGA
Stamford, CT.
CANADA
www.omega.ca
Laval(Quebec)
1-800-TC-OMEGA
GERMANY
www.omega.de
Deckenpfronn, Germany
0800-8266342
Karviná, Czech Republic
FRANCE
www.omega.fr
Guyancourt, France
088-466-342
CZECH REPUBLIC
www.omegaeng.cz
596-311-899
BENELUX
www.omega.nl
Amstelveen, NL 0800-099-33-44
More than 100,000 Products Available!
Temperature
Calibrators, Connectors, General Test and Measurement Instruments, Glass Bulb Thermometers, Handheld Instruments for Temperature Measurement, Ice Point References, Indicating Labels, Crayons, Cements and Lacquers, Infrared Temperature Measurement Instruments, Recorders Relative Humidity Measurement Instruments, RTD Probes, Elements and Assemblies, Temperature & Process Meters, Timers and Counters, Temperature and Process Controllers and Power Switching Devices, Thermistor Elements, Probes and Assemblies,Thermocouples Thermowells and Head and Well Assemblies, Transmitters, Wire
Flow and Level
Air Velocity Indicators, Doppler Flowmeters, Level Measurement, Magnetic Flowmeters, Mass Flowmeters, Pitot Tubes, Pumps, Rotameters, Turbine and Paddle Wheel Flowmeters, Ultrasonic Flowmeters, Valves, Variable Area Flowmeters, Vortex Shedding Flowmeters
pH and Conductivity
Conductivity Instrumentation, Dissolved Oxygen Instrumentation, Environmental Instrumentation, pH Electrodes and Instruments, Water and Soil Analysis Instrumentation
Data Acquisition
Auto-Dialers and Alarm Monitoring Systems, Communication Products and Converters, Data Acquisition and Analysis Software, Data Loggers Plug-in Cards, Signal Conditioners, USB, RS232, RS485 and Parallel Port Data Acquisition Systems, Wireless Transmitters and Receivers
Pressure, Strain and Force
Displacement Transducers, Dynamic Measurement Force Sensors, Instrumentation for Pressure and Strain Measurements, Load Cells, Pressure Gauges, Pressure Reference Section, Pressure Switches, Pressure Transducers, Proximity Transducers, Regulators, Strain Gages, Torque Transducers, Valves
Heaters
Band Heaters, Cartridge Heaters, Circulation Heaters, Comfort Heaters, Controllers, Meters and Switching Devices, Flexible Heaters, General Test and Measurement Instruments, Heater Hook-up Wire, Heating Cable Systems, Immersion Heaters, Process Air and Duct, Heaters, Radiant Heaters, Strip Heaters, Tubular Heaters
click here to go to the omega.com home page
Loading...