Omega Products EP211-X120-10V User Manual

FM
APPROVED
MOUNTING BRACKET
1/2-14 NPT
35.1
(1.38)
38.6
(1.52)
27.9
(1.10)
14.0
(0.55)
5.3
(0.21) DIA
107.7 (4.24)
28.4
(1.12)
35.3
(1.39)
14.0 (0.55)
ALTERNATE OUTPUT/ GAUGE PORT
2 LEADS #18 GA. WIRE 18” LONG (EA.) 1 BLACK (+) 1 WHITE (-)
38.1
#10-32 UNF-2A X.38 DP . (2) MOUNTING HOLES
28.7
(1.13)
Y
Z
X
30.2 SIGNAL
1/4
-18 NPT
(
4
PLACES)
SUPPLY
ALTERNATE OUTPUT/ GAUGE PORT
OUTPUT
REMOVABLE ORIFICE
MAX (Square)
55.4
73.1
SPAN
ZERO
(1.19)
(2.88)
(2.18)
(1.50)
GENERAL PURPOSE ELECTROPNEUMATIC TRANSDUCERS
I/P AND E/P MODELS
IP211 Current to Pressure (I/P) EP211 Voltage to Pressure (E/P)
Starts at
$
Optional
ptional
O
285
IP211-X15, $285,
shown actual size
Low CostBuilt-In Volume BoosterSmall SizeField ReversibleLow Air ConsumptionMounts at Any AngleConvenient External Span and
Zero Adjustment (Except for Explosion-Proof Models)
Light WeightWide Supply Pressure RangeLow Supply Pressure
Sensitivity
The IP211/EP211 Series transducers are electropneumatic devices that reduce a supply pressure to a regulated output pressure directly proportional to an electrical input signal. The 211 Series accepts a wide range of supply pressures, ranging from a minimum of 3 psig (0.2 bar) above the maximum output to 100 psig (6.9 bar). An integral pneumatic volume booster is included in the design to provide high flow capacity (up to 12 SCFM). Model selection includes general purpose, FM Intrinsically Safe, and CSA Intrinsically Safe.
Mounting
These transducers can be pipe, panel, or bracket mounted in any position. Positions other than vertical will require recalibration of the zero adjustment. For maximum output stability, the transducers should be mounted in a vibration- free location or where vibration is isolated in the x and z axes.
Field Reversible
All transducers are calibrated at the factory for direct-acting operation but may be used in the reverse­acting mode by reversing the polarity of the signal leads and recalibrating. When recalibrated
(mounting bracket
included).
for reverse-acting applications, the transducers provide a minimum of their full rated output pressure (i.e.,15, 27, or 30 psig) upon input signal failure.
for specific FM or CSA approved models.
L-5
Refer to the To Order Chart on page L-6
Dimensions:
mm (in)
Easily accessible zero and span adjustments
GENERAL PURPOSE ELECTROPNEUMATIC TRANSDUCERS
SPECIFICATIONS
Supply Pressure Range:
psig (0.2 bar) above maximum output
3 to 120 psig 15 psig (1 bar) units: 18 to 100 psig (1.3 to 7 bar) 27 psig (1.9 bar) units: 30 to 100 psig (1.9 to 7 bar) 30 psig (2.1 bar) units: 33 to 100 psig (2.3 to 7 bar) 60 psig (4.1 bar) units: 65 to 100 psig (4.5 to 7 bar) 120 psig (8.3 bar) units: 125 to 150 psig (8.6 to 10.4 bar)
Supply Pressure Sensitivity:
±0.15 of span 1.5 psig (0.1 bar)
Linearity (Terminal Based):
<1.0% of span
Repeatability: <0.5% of span Hysteresis: <1.0% of span Minimum Flow Rate @ 100 psig
(7 bar): 12 SCFM
To Order
MODEL NO. PRICE INPUT RANGE GENERAL PURPOSE I/P
IP211-X15 $285 4 to 20 mA 3 to 15 0.2 to 1.0 180 Ω IP211-X27 285 4 to 20 mA 3 to 27 0.2 to 1.9 220 Ω IP211-X30 285 4 to 20 mA 6 to 30 0.4 to 2.1 220 Ω IP211-X60 340 4 to 20 mA 2 to 60 0.1 to 4.1 225 Ω IP211-X120 340 4 to 20 mA 3 to 120 0.2 to 8.3 260 Ω
FM APPROVED†INTRINSICALLY SAFE I/P
IP211-X15-ISF $327 4 to 20 mA 3 to 15 0.2 to 1.0 180 Ω IP211-X27-ISF 327 4 to 20 mA 3 to 27 0.2 to 1.9 220 Ω
CSA APPROVED†INTRINSICALLY SAFE I/P
IP211-X15-ISC $327 4 to 20 mA 3 to 15 0.2 to 1.0 180 Ω IP211-X27-ISC 327 4 to 20 mA 3 to 27 0.2 to 1.9 220 Ω
GENERAL PURPOSE E/P
EP211-X15 $285 1 to 5 Vdc 3 to 15 0.2 to 1.0 615 Ω EP211-X15-5V 285 0 to 5 Vdc 3 to 15 0.2 to 1.0 615 Ω EP211-X15-10V 285 0 to 10 Vdc 3 to 15 0.2 to 1.0 985 Ω EP211-X27 285 1 to 5 Vdc 3 to 27 0.2 to 1.9 530 Ω EP211-X27-5V 285 0 to 5 Vdc 3 to 27 0.2 to 1.9 530 Ω EP211-X27-10V 285 0 to 10 Vdc 3 to 27 0.2 to 1.9 840 Ω EP211-X30 285 1 to 5 Vdc 6 to 30 0.4 to 2.1 530 Ω EP211-X30-5V 285 0 to 5 Vdc 6 to 30 0.4 to 2.1 530 Ω EP211-X60-5V 340 0 to 5 Vdc 2 to 60 0.1 to 4.1 500 Ω EP211-X120-10V 340 0 to 10 Vdc 3 to 120 0.2 to 8.3 805 Ω
ACCESSORY
TX4-100 $35 30.48 m (100') of 4-conductor shielded wire
Comes complete with operator’s manual and mounting bracket. Ordering Example: IP211-X30, electropneumatic converter with 6 to 30 psig output, TX4-100, 4-conductor shielded wire,
$285 + 35 = $320.
(Specify Model Number)
Exhaust Capacity @ 5 psig (0.4 bar) Above Setpoint
Air Consumption (Max) at Midrange
Port Size (Pneumatic/Electric)
1
4 NPT and 1⁄2 NPT
Dimensions
1
(2
8 x 21⁄8 x 4")
Maximum Flow: Agency Approvals:
Research Approved as Intrinsically Safe for Class I, II, III, Division 1, Groups A, B, C, D, E, G when installed in accordance with interconnection diagram and with the proper energy limiting barriers. Canadian Standards Association certified as intrinsically safe when connected through certified diode safty barriers in accordance with installation instruction.
Note: Intrinsically safe and non-incendive ratings are not affected by recalibrating for split ranges or reverse-acting applications.
: 0.1 SCFM
: 54 x 54 x 101 mm
24 SCFM (677 SLPM)
: 2 SCFM
:
Factory Mutual
OUTPUT RANGE IMPEDANCE
psig bar
IP211-X15, $285, shown smaller
than actual size.
MOST POPULAR
MODELS HIGHLIGHTED!
(NOMINAL)
L-6