I-4
MECHANICAL ENDURANCE RATINGS
Frequency of Operation:
Pushbuttons: 6000 operations per hr
Push-Pulls: 3000 operations per hr
Push-Push: 1800 cycles per hr
Selector Switches: 3000 operations per hr
Trigger-Action E-Stop: 360 cycles per hr
Twist-to-Release: 1200 cycles per hr
MECHANICAL LIFE
Contact Blocks: 3M operations
Pushbuttons: 5M operations
Push-Pulls: 300,000 operations
Push-Push: 300,000 operations
Selector Switches: 500,000 operations
Trigger-Action E-Stop: 100,000 operations
Twist-to-Release: 300,000 operations
Joysticks: 500,000 operations;
vibration IEC 68-2 (BS 2011)
Vibration: 5 g/0.7 mm peak to peak,
10 sweeps, 10 to 500 Hz
Shock: 30 g, 18 ms
Bump: 25 g, 6 ms for 1000 cycle
ENVIRONMENTAL CONDITIONS
Operating Temperature: -20 to 60°C (-4 to 140°F)
Storage Temperature: -40 to 80°C (-40 to 176°F)
Altitude: Up to 2000 m (6562')
Pollution Degree (IEC 947-1): 3
Humidity: Maximum 95% RH @ 60°C (140°F)
CONTACT BLOCK TERMINAL CLAMPS
Clamp Type: Self-lifting
Screw Type: Plus/minus, captive
Wire Range: 18 to 12 AWG (0.75 to 4.0 mm
2
)
Fingerproof Protection: IP2X
Tightening Torque: 7 lb in (0.8 Nm)
ELECTRICAL RATINGS
Meet or exceed NEMA contact rating designations A600 and Q600
A600: Q600 per UL 508
AC15: DC13 per IEC 60947-5-1
Logic Level Contact Blocks:
UL A600,
Q600 and IEC AC15, DC13 rated and also
have a minimum rating of 1 mA @ 5 Vdc
Impulse Withstand Voltage (Uimp): 4 kV
Short Circuit Coordination to IEC/EN 60947-5-1:
Rated Conditional Short Circuit Current: 1 kA
Fuse Type: GE power controls TIA 10, red spot type gG,
10 A, 660 Vac, 460 Vdc, BS88-2, IEC 60269-2-1
ELECTRICAL LIFE
AC15 Durability:
120V: 6 A – 1 x 106 operations
DC13 Durability:
24V: 4 A – 0.15 x 106 operations
660V: 0.1 A – 0.5 x 106 operations
MATERIAL
Housing, Bezel, Mounting Rings: Glass filled nylon
Metal Bezels: Chrome plated brass
Internal Seal: Nitrile rubber
Panel Gasket: Nitrile rubber
Illuminated Lenses: Polycarbonate
Buttons: Polyester or polycarbonate
Contacts: Silver
Terminals: Brass
TERMINAL MARKINGS
All rear of panel devices are marked with
the circuit configuration per CENELLEC 500013 standards.
l E22CB1, E22CB11, E22CB1E, E22B1, and E22B11 contact blocks are
marked with Direct Opening Action (DOA) symbol per IEC 60947-5-1,
Annex K and NEMA ICS 5, Part 6. For mechanical operating parameters.
l E22CB1, E22CB11 and E22CB1E contact blocks will be marked as suitable
for isolation per IEC 60947-5-1.
Plunger
Circuit Configuration Description Color
1 NC Red
1 NO Green
1 NO-1 NC White
2 NO Green
1 NO
Black
Early Make
1 NC
Gray
Late Break
Circuit Configuration Description
Full Voltage
Resistor
Transformer
CONTACT BLOCKS
LIGHTED UNITS
A600 Vac Q600 Vdc
Description 120 240 480 600 125 250 440 600
Make and 60 30 15 12 0.55 0.27 0.1 0.1
emergency
interrupting
capacity (A)
Normal load 6 3 1.5 1.2 0.55 0.27 0.1 0.1
break (A)
Thermal 10 10 10 10 2.5 2.5 2.5 2.5
current (A)
1
Ratings do not apply to rotary cam switches.