Omega Products E26B0V2 User Manual

MODULAR STACKLIGHTS
E26 Series
Starts at
$
189
Basic
Assembly
l Modular Construction l Six Lens Colors l Variety of Lamp Types and Voltages l Mono-Tonal, Bi-Tonal and
Intermittent Audible Alarms
l Combination of Visible and
l Modular Components Reduce
Inventory Requirements, Increase Flexibility
l Steady and Flashing Modes
Allow One Light to Signal Multiple Conditions
l No-Tools Assembly Permits
Easy Lamp Replacement
For Our Complete Line of Stacklights
Visit
omegamation.com/
stacklights
The E26 stacklight unit is a modular system that provides illuminated and audible status indication in all directions. Easily assembled plug-in modular units include constant, flashing and strobe light units, as well as bi-tonal alarm systems. Stacklights may be assembled in a variety of configurations. Numerous lamp, color and mounting options further enhance the stacklight’s versatility.
ASSEMBLING A STACKLIGHT SYSTEM
1) Select a Base Unit
Two base units are available, the standard base unit or a flashing base.
2) Select an Extension Tube
Models are available in lengths from 1 inch to 14 inches as well as with right angle design.
3) Select an Optional Mounting Plate
The standard 4 hole mounting plate attaches to the bottom of the bottom of the extension tube to provide an easy and secure means of mounting the stack light.
4) Select up to Six Light Modules
Light modules are available in a variety of colors with either incandescent or LED light sources. The incandescent lights are lower cost and brighter than the LEDs, however, the LEDs have a greater bulb life.
5) Optional Alarm Module
The bi-tonal alarm module mounts on the top of the stack. When used only 5 light modules may be used.
BASE UNITS
STANDARD STACKLIGHT BASE
For use with incandescent or standard LED for steady, non-flashing illumination or with flashing LEDs for flashing illumination. Bases include terminal block for wiring, stacklight cover and gasket.
FLASHING STACKLIGHT BASE
Allows configuration of each light in the stack for either steady or 60 times per minute flashing illumination. Flashing circuit for use with incandescent lamps only.
To Order (Specify Model Number)
MODEL NUMBER PRICE DESCRIPTION BASES
E26BL $64.00 Standard base 12 Vac/dc to 240 Vac/dc E26BFV4 162.00 Flashing base 120 Vac/dc
EXTENSION TUBES
E26BHU $18.00 Black extension tube 1" E26BJU 35.50 Black extension tube 6" E26BKU 57.00 Black extension tube 14" E26BRU 18.50 Black right angle extension tube
MOUNTING PLATE
E26S109 $25.50 Standard 4-hole mounting base
I-31
MOST POPULAR MODELS HIGHLIGHTED!
SPECIFICATIONS
Standards and Certifications:
CE 60947-5-1 UL 508—File #E131568 cUL C22.2 No. 14—File #E131568
Ingress Protection:
Stacklight Base and Light Units:
NEMA 4 (IP65), 4X and 13
Alarm Units: NEMA 1 (IP20)
Electrical Shock Protection:
Stacklight Base and Light Unit: IP2X Alarm Units: IP0X
Mechanical Ratings:
Shock (IEC 68-2-27): 11 mS, 15 g Vibration (IEC 68-2-6): 10 sweeps,
10 to 150 Hz, 2 g Bump (IEC 68-2-29): 1000 pulses,
6 mS, 15 g
Climate Conditions:
Operating: Maximum 40°C (104°F)
at 95% RH, temperature -20 to 60°C (-4 to 140°F)
Storage Temperature: -40 to 80°C (-40 to 176°F)
Materials:
Cover: Polycarbonate Lenses: Polycarbonate Stacklight Base: Nylon Extension Tubes: Aluminum Mounting Base: Zinc die cast
Terminals:
Single Conductors: 14 to 30 AWG
(2.5 to 0.05 mm
2
)
Two Conductors of the Same Size:
18 to 26 AWG (0.75 to 0.14 mm2)
Do not mix solid and stranded wire in the same terminal.
Recommended Tightening Torque:
0.5 to 0.6 Nm (4.4 to 5.3 lb-in)
Electrical Ratings:
Insulation Voltage (Ui): 690V Operational Voltage (Ue): 250V Impulse Withstand Voltage (Uimp):
1.5 kV
BULB SPECIFICATIONS Incandescent Lamp Type: BA15d Maximum Lamp Wattage: 6 W Bulbs—Average Life:
Incandescent: 7000 to 12,000 hrs
(based on voltage) LED: 60,000 to 100,000 hrs
(based on colors)
LED/INCANDESCENT COMPARISON Incandescent Lamps: Average
operating life of 7000 hours; each lamp can be used with any color lens; low cost results in short term savings
LED Lamps: Average operating life of 60,000 to 100,000 hours; low power consumption; extended life results in long-term savings
E26 STACKLIGHT INCANDESCENT APPLICATION DATA
TYPE OF LIGHT LAMP USED CURRENT, mA PER LIGHT HOURS AS APPLIED
12V BA15d 417 7000 24V BA15d 208 7000
48V BA15d 104 7000 110 to 140V BA15d 36 to 50 7000 220 to 260V BA15d 23 to 27 12,000
APPROXIMATE THEORETICAL LAMP LIFE,
E26 STACKLIGHT LED APPLICATION DATA, CONTINUOUS/FLASHING LED
TYPE AT RATED VOLTS LAMP LIFE, HOURS
OF LIGHT COLOR CLUSTER LED CYLINDRICAL LED AS APPLIED
12 Vac/Vdc Red 92 92 100,000
24 Vac/Vdc Red 47 47 100,000
48 Vac/Vdc Red 25 25 100,000
60 Vac/Vdc Red 25 25 100,000
120 Vac/Vdc Red 24 24 100,000
Note: Published theoretical lamp lives are based on ideal laboratory conditions and should be used for comparison only. Actual life may be shorter due to various application conditions.
Amber 92 92 100,000 Yellow 92 92 100,000
Green 60 60 80,000
Blue 60 60 60,000
White 60 60 60,000
Amber 47 47 100,000 Yellow 47 47 100,000
Green 59 59 80,000
Blue 59 59 60,000
White 59 59 60,000
Amber 25 25 100,000 Yellow 25 25 100,000
Green 18 18 80,000
Blue 31 31 60,000
White 31 31 60,000
Amber 25 25 100,000 Yellow 25 25 100,000
Green 18 18 80,000
Blue 17 17 60,000
White 17 17 60,000
Amber 24 24 100,000 Yellow 24 24 100,000
Green 17 17 80,000
Blue 16 16 60,000
White 16 16 60,000
APPROXIMATE CURRENT, mA THEORETICAL
I-32
65432
1
2
3
4
5
6
1C
External
Switching
Devices
-
Supply
Factory
Wiring
Field
Wiring
C123456
F
Standard Base
or
or
or
or
or
or
Cover
Alarm
O-Ring
Light
Diffuser
Te rm inal
Board
Set Screw
Recommended
Tightening
To rq ue
Is 7 in-lb
(0.79 Nm)
Mounting
Gasket
Lens
Lamp
O-Ring
Mounting
Base
Stacklight
Base
Typical Stacklight Assembly
(Exploded View)
Alternate Conduit Hub
Myers Type
ST-2 or
ST-2CP Hub
Panel
Extension
Tube
O-Rings
Flasher
Flasher
Base Voltage
Max Allowable
No. of Light
Modules
6240 Vac/Vdc
6120 Vac/Vdc
648 Vac/Vdc
424 Vac/Vdc
212 Vdc
Flashing Base
Orange Flasher
Wire
C1
7 8 9 10
23456
65432
1
2
3
4
5
6
1
10
9
Flashing
Module
87
C
External
Switching
Devices
Steady
Circuit
Flashing
Circuit
Orange
Wire
-
Supply
or
or
or
STANDARD AND FLASHING BASES, MOUNTING
Typical Stacklight Assemblies
Note:
1. Bases also suitable for mounting with extension tubes
2. Mounting gasket and cover are supplied as standard with stacklight bases
3. Audible alarm units must be wired via the steady circuit on flashing base units
4. Audible alarm units can be wired in positions as shown but only one unit is permitted on each stack and unit must occupy the last or top mounting position