l Modular Construction
l Six Lens Colors
l Variety of Lamp Types and Voltages
l Mono-Tonal, Bi-Tonal and
Intermittent Audible Alarms
l Combination of Visible and
Audible Alarms
l Modular Components Reduce
Inventory Requirements,
Increase Flexibility
l Steady and Flashing Modes
Allow One Light to Signal
Multiple Conditions
l No-Tools Assembly Permits
Easy Lamp Replacement
For Our
Complete Line
of Stacklights
Visit
omegamation.com/
stacklights
The E26 stacklight unit is a modular system
that provides illuminated and audible status
indication in all directions. Easily assembled
plug-in modular units include constant,
flashing and strobe light units, as well as
bi-tonal alarm systems. Stacklights may be
assembled in a variety of configurations.
Numerous lamp, color and mounting options
further enhance the stacklight’s versatility.
ASSEMBLING
A STACKLIGHT SYSTEM
1) Select a Base Unit
Two base units are available, the
standard base unit or a flashing base.
2) Select an Extension Tube
Models are available in lengths from
1 inch to 14 inches as well as with right
angle design.
3) Select an Optional Mounting Plate
The standard 4 hole mounting plate
attaches to the bottom of the bottom of
the extension tube to provide an easy
and secure means of mounting the
stack light.
4) Select up to Six Light Modules
Light modules are available in a variety
of colors with either incandescent or
LED light sources. The incandescent
lights are lower cost and brighter than
the LEDs, however, the LEDs have a
greater bulb life.
5) Optional Alarm Module
The bi-tonal alarm module mounts on
the top of the stack. When used only
5 light modules may be used.
BASE UNITS
STANDARD STACKLIGHT BASE
For use with incandescent or standard
LED for steady, non-flashing
illumination or with flashing LEDs for
flashing illumination. Bases include
terminal block for wiring, stacklight
cover and gasket.
FLASHING STACKLIGHT BASE
Allows configuration of each light in the
stack for either steady or 60 times per
minute flashing illumination. Flashing
circuit for use with incandescent
lamps only.
To Order (Specify Model Number)
MODEL NUMBERPRICEDESCRIPTION
BASES
E26BL$64.00Standard base 12 Vac/dc to 240 Vac/dc
E26BFV4162.00Flashing base 120 Vac/dc
Do not mix solid and stranded wire in the
same terminal.
Recommended Tightening Torque:
0.5 to 0.6 Nm (4.4 to 5.3 lb-in)
Electrical Ratings:
Insulation Voltage (Ui): 690V
Operational Voltage (Ue): 250V
Impulse Withstand Voltage (Uimp):
1.5 kV
BULB SPECIFICATIONS
Incandescent Lamp Type: BA15d
Maximum Lamp Wattage: 6 W
Bulbs—Average Life:
Incandescent: 7000 to 12,000 hrs
(based on voltage)
LED: 60,000 to 100,000 hrs
(based on colors)
LED/INCANDESCENT COMPARISON
Incandescent Lamps: Average
operating life of 7000 hours; each lamp
can be used with any color lens; low
cost results in short term savings
LED Lamps: Average operating life of
60,000 to 100,000 hours; low power
consumption; extended life results in
long-term savings
E26 STACKLIGHT INCANDESCENT APPLICATION DATA
TYPE OF LIGHT LAMP USEDCURRENT, mA PER LIGHTHOURS AS APPLIED
12V BA15d 417 7000
24V BA15d 208 7000
48V BA15d 104 7000
110 to 140V BA15d 36 to 50 7000
220 to 260V BA15d 23 to 27 12,000
APPROXIMATE THEORETICAL LAMP LIFE,
E26 STACKLIGHT LED APPLICATION DATA, CONTINUOUS/FLASHING LED
TYPEAT RATED VOLTSLAMP LIFE, HOURS
OF LIGHTCOLORCLUSTER LEDCYLINDRICAL LEDAS APPLIED
12 Vac/VdcRed 92 92 100,000
24 Vac/Vdc Red 47 47 100,000
48 Vac/Vdc Red 25 25 100,000
60 Vac/Vdc Red 25 25 100,000
120 Vac/VdcRed 24 24 100,000
Note: Published theoretical lamp lives are based on ideal laboratory conditions and should be used for comparison
only. Actual life may be shorter due to various application conditions.
Amber9292100,000
Yellow9292100,000
Green 60 60 80,000
Blue 60 60 60,000
White 60 60 60,000
Amber47 47 100,000
Yellow4747100,000
Green 59 59 80,000
Blue 59 59 60,000
White 59 59 60,000
Amber 25 25 100,000
Yellow 25 25 100,000
Green 18 18 80,000
Blue 31 31 60,000
White 31 31 60,000
Amber 25 25 100,000
Yellow 25 25 100,000
Green 18 18 80,000
Blue 17 17 60,000
White 17 17 60,000
Amber 24 24 100,000
Yellow 24 24 100,000
Green 17 17 80,000
Blue 16 16 60,000
White 16 16 60,000
APPROXIMATE CURRENT, mA THEORETICAL
I-32
65432
1
2
3
4
5
6
1C
External
Switching
Devices
-
Supply
Factory
Wiring
Field
Wiring
C123456
F
Standard Base
or
or
or
or
or
or
Cover
Alarm
O-Ring
Light
Diffuser
Te rm inal
Board
Set Screw
Recommended
Tightening
To rq ue
Is 7 in-lb
(0.79 Nm)
Mounting
Gasket
Lens
Lamp
O-Ring
Mounting
Base
Stacklight
Base
Typical Stacklight Assembly
(Exploded View)
Alternate Conduit Hub
Myers Type
ST-2 or
ST-2CPHub
Panel
Extension
Tube
O-Rings
Flasher
Flasher
Base Voltage
Max Allowable
No. of Light
Modules
6240 Vac/Vdc
6120 Vac/Vdc
648 Vac/Vdc
424 Vac/Vdc
212 Vdc
Flashing Base
Orange Flasher
Wire
C1
7 89 10
23456
65432
1
2
3
4
5
6
1
10
9
Flashing
Module
87
C
External
Switching
Devices
Steady
Circuit
Flashing
Circuit
Orange
Wire
-
Supply
or
or
or
STANDARD AND FLASHING
BASES, MOUNTING
Typical Stacklight Assemblies
Note:
1. Bases also suitable for mounting with extension tubes
2. Mounting gasket and cover are supplied as standard with
stacklight bases
3. Audible alarm units must be wired via the steady circuit
on flashing base units
4. Audible alarm units can be wired in positions as shown but
only one unit is permitted on each stack and unit must
occupy the last or top mounting position
I-33
Dimensions: mm (in)
44
(1.75)
59
(2.32)
65
(2.56)
15
(0.59)
42.9
(1.69)
A
Tube Extension Height A
20 (0.79)
160 (6.30)
360 (14.17)
760 (29.92)
45 (1.77)
185 (7.28)
385 (15.16)
785 (30.91)
He
63.5
(2.50)
50.8
(2.00)
Right Angle Extension Tube
STANDARD AND FLASHING BASES, MOUNTING
ALARM UNITS
To Order
(Specify Model Number)
MODEL NO.PRICEDESCRIPTION
E26BNV4$162NEMA 1 (IP20) bi-tonal
AVAILABLE FOR
FAST DELIVERY!
audible alarm, volume
adjustment range:
64 to 90 dB typical current
draw 11.5 mA, 120 Vac/Vdc
EXTENSION TUBES*
To Order
(Specify Model Number)
MODEL NO.PRICEDESCRIPTION
E26BL$6412 to 240 Vac/Vdc standard base
E26BFV4162120 Vac/Vdc flashing base
Dimensions: mm (in)
AVAILABLE FOR
FAST DELIVERY!
for use with steady incandescent
or steady/flashing LED
enables configuration of
incandescent light modules for
steady or flashing operation
To Order (Specify Model Number)
MODEL NO.PRICEDESCRIPTION
E26BHU$18.0020 mm (0.79") extension
E26BJU35.50160 mm (6.30") extension
E26BKU57.00360 mm (14.17") extension
E26BRU18.50Right angle extension tube
For use with standard mounting base or
*
black aluminum.
AVAILABLE FOR FAST DELIVERY!
3
⁄4 NPT threaded hub—
I-34
Stacklight
Base
Customer
Supplied
Customer
Supplied
Mounting
Gasket
Panel
Base Mounting
Set Screw
Recommended
Tightening Torque
is 0.79 Nm
(7 in-lb)
Mounting
Base
Mounting
Gasket
Panel
Utilizing Extension
Tube and Mounting Base
Stacklight
Base
Extension
Tube
O-Rings
Set Screw
Recommended
Tightening Torque
is 0.79 Nm
(7 in-lb)
Extension
Tube
O-Rings
Myers Type
ST-2 or
ST-2CP Hub
Panel
Stacklight
Base
Utilizing Extension Tube and
19.1 (0.75) Conduit Hub
(Use Rubber-Jawed
Pliers for Installation
to Avoid Scratching the
Black Anodized Coating)
44.5 (1.75)
or 42.0 (1.65)*
4.6 (0.18) Dia.
or #8–32 Thread
or (M4 x 0.7)
22.1
(0.87)
Dia.
Base Mounting
120°
22.1
(0.87)
48.8 (1.92)
Dia.
4.6 (0.18) Dia.
or #8–32 Thread
or (M4 x 0.7)
Dia.
3-Hole Mounting for E26S108
90°
22.1
(0.87)
53.8 (2.12)
Dia.
5.08 (0.20) Dia.
or #10–32 Thread
or (M5 x 0.7)
Dia.
4-Hole Mounting for E26S109
27
(1.06)
Dia.
19.1 (0.75) Conduit
Hub for E26S104
MOUNTING
Stacklight bases may be mounted without the use of extension tube or mounting base. If additional height
is required, choose 20 to 760 mm (0.8 to 30") extension tubes that fit between the mounting base and
stacklight base. The extension tubes are threaded with
to conduit fittings or threaded holes without the use of a mounting base.
3
⁄4 NPT threads, allowing for direct connection
* Stacklight base and gasket are supplied as standard with two sets of base mount holes.
One set with center-to-center spacing of 44.5 mm (1.75") and another set with center-to-center spacing of 42 mm (1.65")
I-35
Dimensions: mm (in)
DIMENSIONS
65 (2.56)
Light
Unit
Base
Light
Unit
Base
15 (0.59)
69 (2.72)
44 (1.73)
Standard
65 (2.56)
Alarm
Base
57 (2.24)
69 (2.72)
44 (1.73)
With Alarm
65 (2.56)
69 (2.72)
15 (0.59)
69 (2.72)
44 (1.73)
With Xenon Flasher
Xenon
Light
Unit
(2 High)
69 (2.72)
15 (0.59)
69 (2.72)
44 (1.73)
69 (2.72)
44 (1.73)
69 (2.72)
65 (2.56)
69 (2.72)
15 (0.59)
69 (2.72)
44 (1.73)
69 (2.72)
With Xenon FlasherWith AlarmStandard
Light
Unit
Light
Unit
Base
Light
Unit
Light
Unit
Base
Base
65 (2.56)
Xenon
Light
Unit
(2 High)
Light
Unit
65 (2.56)
Alarm
57 (2.24)
69 (2.72)
15 (0.59)
69 (2.72)
44 (1.73)
69 (2.72)
69 (2.72)
With Xenon Flasher
Base
65 (2.56)
Xenon
Light
Unit
(2 High)
Light
Unit
Light
Unit
15 (0.59)
69 (2.72)
44 (1.73)
69 (2.72)
69 (2.72)
Standard
Base
65 (2.56)
Light
Unit
Light
Unit
Light
Unit
69 (2.72)
44 (1.73)
69 (2.72)
69 (2.72)
With Alarm
Base
65 (2.56)
Light
Unit
Light
Unit
Light
Unit
Alarm
57 (2.24)
65 (2.56)
Standard
15 (0.59)
69 (2.72)
One-Light Unit StacklightDimensions: mm (in)
Two-Light Unit StacklightDimensions: mm (in)
Light Modules
Cover included with stacklight base.
Dimensions: mm (in)
Three-Light Unit StacklightDimensions: mm (in)
I-36
LIGHT MODULES
Available in a variety of colors for both incandescent lamps and LED lamps. To maximize illumination
and light dispersion, incandescent units include an opal white diffuser while LED diffusers are clear.
Calibrators, Connectors, General Test and Measurement
Instruments, Glass Bulb Thermometers, Handheld Instruments
for Temperature Measurement, Ice Point References,
Indicating Labels, Crayons, Cements and Lacquers, Infrared
Temperature Measurement Instruments, Recorders Relative
Humidity Measurement Instruments, RTD Probes, Elements
and Assemblies, Temperature & Process Meters, Timers and
Counters, Temperature and Process Controllers and Power
Switching Devices, Thermistor Elements, Probes and
Assemblies,Thermocouples Thermowells and Head and Well
Assemblies, Transmitters, Wire
Flow and Level
Air Velocity Indicators, Doppler Flowmeters, Level
Measurement, Magnetic Flowmeters, Mass Flowmeters,
Pitot Tubes, Pumps, Rotameters, Turbine and Paddle Wheel
Flowmeters, Ultrasonic Flowmeters, Valves, Variable Area
Flowmeters, Vortex Shedding Flowmeters
pH and Conductivity
Conductivity Instrumentation, Dissolved Oxygen
Instrumentation, Environmental Instrumentation, pH
Electrodes and Instruments, Water and Soil Analysis
Instrumentation
Data Acquisition
Auto-Dialers and Alarm Monitoring Systems,
Communication Products and Converters, Data
Acquisition and Analysis Software, Data Loggers
Plug-in Cards, Signal Conditioners, USB, RS232, RS485
and Parallel Port Data Acquisition Systems, Wireless
Transmitters and Receivers
Band Heaters, Cartridge Heaters, Circulation Heaters,
Comfort Heaters, Controllers, Meters and Switching
Devices, Flexible Heaters, General Test and Measurement
Instruments, Heater Hook-up Wire, Heating Cable
Systems, Immersion Heaters, Process Air and Duct,
Heaters, Radiant Heaters, Strip Heaters, Tubular Heaters
click here to go to the omega.com home page
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.