SPECIFICATIONS
Inputs
Voltage Input
Ranges: 100mV to 200VAC
Impedance: >100KΩ
Overvoltage: 300VAC
Current Input
Ranges:10mA to 100mAAC
Impedance: 20Ω, typical
Overcurrent: 200mAAC
Overvoltage: 60V peak
Frequency Range: 40 to 400Hz,
factory calibrated at 60Hz
Common Mode(Input to Ground):
1800VDC, max.
Zero and Span Range:
Zero Turn-Up: 50% of full
scale range
Span Turn-Down: 50% of full
scale range
Output
Voltage Output
Output: 0-5V, 0-10V
Source Impedance: <10Ω
Drive: 10mA, max.
(1KΩ, min. @ 10V)
OMEGAnetSM On-Line Service
http://www.omega.com
USA:
ISO 9001 Certified
Canada:
USA and Canada:
Mexico and
Latin America:
Benelux:
Czech Republic:
France:
Germany/Austria:
United Kingdom:
ISO 9002 Certified
One Omega Drive, Box 4047
Stamford, CT 06907-0047
Telephone: (203) 359-1660
e-mail:info@omega.com
976 Bergar
Laval (Quebec) H7L 5A1
Telephone: (514) 856-6928
e-mail: canada@omega.com
Sales Service: 1-800-826-6342 / 1-800-TC-OMEGA
Customer Service: 1-800-622-2378 / 1-800-622-BEST
Engineering Service: 1-800-872-9436 / 1-800-USA-WHEN
TELEX: 996404 EASYLINK: 62968934 CABLE: OMEGA
Tel: (95) 800-TC-OMEGA
En Espanol: (203) 359-1660 ext. 2203
Postbus 8034, 1180 LA Amstelveen, The Netherlands
Tel: (31) 20 6418405
Toll Free in Benelux: 06 0993344
e-mail: nl@omega.com
Ostravska 767, 733 01 Karvina
Tel: 42 (69) 6311899
e-mail: czech@omega.com
9, rue Denis Papin, 78190 Trappes
Tel:33 0130-621-400
Toll Free in France: 05-4-06342
e-mail: france@omega.com
Daimlerstrasse 26, D-75392 Deckenpfronn, Germany
Tel:49 (07056) 3017
Toll Free in Germany: 0130 11 21 66
e-mail: germany@omega.com
25 Swannington Road,
Broughton Astely, Leicestershire,
LE9 6TU, England
Tel: 44 (1455) 285520
Fax: 44 (1455) 283912
Servicing North America:
For immediate technical sevice or application assistance:
Servicing Europe:
Toll Free in England: 0800-488-488
e-mail: uk@omega.com
SM
Internet e-mail
info@omega.com
Fax: (203) 359-7700
Fax: (514) 856-6886
SM
SM
Fax: (95) 203-359-7807
e-mail: espanol@omega.com
Fax: (31) 20 6434643
Fax: 42 (69) 6311114
Fax: 33 0130-699-120
Fax: 49 (07056) 8540
P.O. Box 7, Omega Drive
Irlam, Manchester,
M44 5EX, England
Tel: 44 (161) 777-6611
Fax: 44 (161) 777-6622
Current Output
Output: 0-1mA, 0-20mA,
4-20mA
Source Impedance: >100KΩ
Compliance:
0-1mA; 7.5V, max. (7.5KΩ, max.)
0-20mA; 12V, max. (600Ω, max.)
4-20mA; 12V, max. (600Ω, max.)
LED Indicator (green)
8Hz flash when input is 10%
above full scale range (FSR)
Accuracy (Including Linearity, Hysteresis)
+0.1% of span, typical
+0.5% of span, maximum
Stability
+0.025%/°C of selected input
span, typical.
Response Time (10 to 90%)
250mSec., typical.
Common Mode Rejection
DC to 60Hz: 120dB
Isolation
1800VDC between input, output
and power.
EMC Compliance (CE Mark)
Emissions: EN50081-1
Immunity: EN50082-2
Safety: EN50178
OMEGA ENGINEERING, INC. warrants this unit to be free of manufacturing defects for the life of the product.
If the unit should malfunction, it must be returned to the factory for evaluation. OMEGA's Customer Service Department will issue an Authorized Return (AR) number
immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective it will be repaired or replaced at no charge. OMEGA's
WARRANTY does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design
limits, improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of being damaged
as a result of excessive corrosion; or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating conditions outside of OMEGA's
control. Components which wear are not warranted, including but not limited to contact points, fuses, and triacs.
OMEGA is pleased to offer suggestions on the use of its various products. However, OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any
damages that result from the use of its products in accordance with information provided by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by
it will be as specified and free of defects. OMEGA MAKES NO OTHER W ARRANTIES OR REPRESENT A TIONS OF ANY KIND WHA TSOEVER, EXPRESSED OR IMPLIED,
EXCEPT THAT OF TITLE, AND ALL IMPLIED W ARRANTIES INCLUDING ANY W ARRANTY OF MERCHANT ABILITY AND FITNESS FOR A P ARTICULAR PURPOSE
ARE HEREBY DISCLAIMED. LIMITA TION OF LIABILITY : The remedies of purchaser set forth herein are exclusive and the total liability of OMEGA with respect to this order ,
whether based on contract, warranty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no
event shall OMEGA be liable for consequential, incidental or special damages.
CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a "Basic Component" under 10 CFR 21 (NRC), used in or with any nuclear
installation or activity; or (2) in medical applications or used on humans. Should any Product(s) be used in or with any nuclear installation or activity, medical application,
SM
used on humans, or misused in any way, OMEGA assumes no responsibility as set forth in our basic W ARRANTY/DISCLAIMER language, and additionally, purchaser will
indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product(s) in such a manner.
Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER
MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGA'S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING
DELAYS). The assigned AR number should then be marked on the outside of the return package and on any correspondence.
The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in transit.
FOR WARRANTY RETURNS, please have the following information
available BEFORE contacting OMEGA:
1. P.O. number under which the product was PURCHASED,
2. Model and serial number of the product under warranty, and
3. Repair instructions and/or specific problems relative to the product
OMEGA's policy is to make running changes, not model changes, whenever an improvement is possible. This affords our customers the latest in technology and
engineering.
OMEGA is a registered trademark of OMEGA ENGINEERING, INC.
ã Copyright 1996 OMEGA ENGINEERING, INC. All rights reserved. This documentation may not be copied, photocopied, reproduced, translated, or reduced to any
electronic medium or machine-readable form, in whole or in part, without prior written consent of OMEGA ENGINEERING, INC.
It is the policy of OMEGA to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification of its products to the European
New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification.
The information contained in this document is believed to be correct but OMEGA Engineering, Inc. accepts no liability for any errors it contains, and reserves the right to alter
specifications without notice.
WARNING: These product are not designed for use in, and should not be used for, patient connected applications.
Humidity (Non-Condensing)
Operating: 15 to 95% (@ 45°C)
Soak: 90% for 24 hours (@ 65°C)
Temperature Range
Operating: 0 to 55°C
(32 to 131°F)
Storage: -25 to 70°C
(-13 to 158°F)
Power
Consumption: 1.5W typical,
2.5W max.
Range: 9 to 30VDC
Wire Terminations
Screw terminals for 12-22 AWG
Agency Approvals
CSA certified per standard C22.2,
No. 0-M91 and 142-M1987 (File No.
LR42272). UL recognized per standard UL508 (File No.E99775).CE
Compliance per EMC directive 89/
336/EEC and Low Voltage 73/23/EE.
Mounting
32mm and 35mm DIN Rail
PIN CONNECTIONS
11 DC Power (+)
12 DC Power (-)
21 DC Power (+)
22 DC Power (-)
41 AC Signal Input (Hot)
42 AC Signal Input (Neu)
51 Output (+)
52 Output (-)
WARRANTY/DISCLAIMER
RETURN REQUEST/ INQUIRIES
FOR NON-WARRANTY REPAIRS, consult OMEGA for current repair
charges. Have the following information available BEFORE contacting OMEGA:
1. P.O. number to cover the COST of the repair,
2. Model and serial number of product, and
3. Repair instructions and/or specific problems relative to the product.
721-0610-00B 11/96
DRG-SC-AC
AC Input, Field Configurable Isolator
Instruction Sheet M2389/0796
DESCRIPTION
The field configurable DRG-SC-AC is
a DIN rail mount, AC input signal
conditioner with 1800VDC isolation
between input, output and power. The
field configurable input and output
offers flexible, wide ranging capability
for scaling, converting or buffering
AC inputs ranging from 5mA to
100mAAC or 50mV to 200VAC. The
DC output of the DRG-SC-AC is proportional to the average of the of the
fully-rectified AC input signal, and is
calibrated for sine waves between 40400Hz.
For current inputs above 100mAAC, it
is recommended that an input shunt
resistor be used and the DRG-SC-AC
be configured for the proper input
range. For example, a 5AAC current
transformer output can use a 0.1Ω,
5W shunt resistor and set the input of
the DRG-SC-AC for 0-500mVAC.
APPLICATION
The DRG-SC-AC is useful in applications requiring an isolated, conditioned
DC output from an AC signal. Typical
applications include energy management, load shedding, motor current/
load monitoring, locked rotor detection, isolation and data acquisition.
The output of the DRG-SC-AC can
drive a digital meter for direct display
or can interface with alarming or control devices including PLCs and computers.
DIAGNOSTIC LED
The DRG-SC-AC is equipped with a
dual function LED signal monitor. The
green, front mounted LED indicates
both DC power and input signal status.
Active DC power is indicated by an
illuminated LED. If the input signal is
more than 110% of the full-scale range,
the LED will quickly flash at 8Hz. If this
continues to occur, you may wish to
change your full-scale input range
setting.
CONFIGURATION
A major advantage of the
DRG-SC-AC is its wide ranging capabilities and ease of configuration. The
DRG-SC-AC has 15 input range switch
settings.
Trim potentiometers allow 50% input
zero and span adjustablity within each
of the 15 full-scale input ranges.
For example, the 200V switch setting
in Table 1 configures the input for a 0
to 200VAC range. Since the span can
be contracted by 50%, this enables an
input span as narrow as 100VAC of
the range. This span can be positioned anywhere within the 0-200VAC
range with a zero offset as large as
50% of the full scale range (e.g. 100
to 200VAC range).
Note1: All DRG-Series modues are designed and tested to operate in ambient temperatures from 0 to 55°C, when
mounted on a horizontal DIN rail. When five or more modules are mounted on a vertical rail, circulating air or model
DRG-HS01 Heat Sink is recommended.
Unless otherwise specified, the
factory presets the Model
DRG-SC-AC as follows:
Input Range: 0-500mVAC
Output: 4-20mA
WARNING:
change any switch settings with power
applied. Severe damage will result!
Do not attempt to
The DC power input accepts any DC
source between 9 and 30V, typically a
12V or 24VDC source is used
Refer to Tables 1 through 3 for the
proper switch settings. With power
disconnected, use the switches on
SW1 to select the input type (voltage or
current), on SW2 to select the HI or LO
input ranges, and on SW4 to select the
desired input range. Using the
switches on SW3, select the desired
type of output.