Thermocouples, RTDs,
DC Voltage and Current,
Frequency, Strain Gage
Bridge, AC Voltage and
Current
U Field Configurable Input
and Output Ranges
U Five Field Configurable
Output Ranges: 0 to 5 V,
0 to 10 V, 0 to 1 mA,
0 to 20 mA and 4 to 20 mA
U Slim Housing Mounts on
DIN Rail for High Density
Installations
U 1800 Volts Isolation
Between Input, Output and
Power Supply
The DRG Series signal
conditioner modules accept a
wide variety of input signals such
as thermocouples, RTDs, strain
gages, DC voltages/currents,
AC voltages/currents, frequency
and potentiometers and produce a
proportional conditioned process
output. The inputs and outputs are
both field configurable and offer
flexible wide ranging capability.
The slim housing mounts on a DIN
rail and is ideal for high density
installation. All modules provide
1800 Vdc isolation between the
input, output and power supply.
Field Configurable
One advantage of the DRG series
is the field configurable input and
output ranges. Each module can
be set to a number of ranges by
dip switch selection. Wide
ranging precision zero and span
potentiometers provide even further
adjustment. The signal conditioners
may be set for an almost limitless
number of ranges. Range
adjustment requires the use of a
calibrator or reference source.
12.7
(0.496)
A/IN
STYLE A
A/OUT
OR
DIMENSIONS
ARE IN
MM (INCHES)
FRONT VIEW
STYLE B
17.7
(0.697)
110.2
32MM DIN RAIL
(4.34)
105.2
35MM DIN RAIL
(4.14)
88.5
(3.48)
SIDE VIEW - STYLE A or B
STYLE A OR B
DIMENSIONS
ARE IN
MM (INCHES)
90.0
(3.54)
To Order Visit omega.com/drg-sc for Pricing and Details
Model No. Description Case Style
DRG-SC-AC AC Voltage and Current A
DRG-SC-BG Strain Gage Bridge B
DRG-SC-DC-B DC Voltage and Current (bipolar) A
DRG-SC-DC-U DC Voltage and Current (unipolar) A
DRG-SC-FR Frequency A
DRG-SC-PT Potentiometer A
DRG-SC-RTD RTD B
DRG-SC-TC Thermocouple B
To Order, Call or Shop Online at omega.com
SM
1
Specifications
DRG-SC-AC
Range (voltage mode):
100 mV to 200 Vac
Impedance (voltage mode):
>100 KΩOverload (voltage mode):
300 Vac, max.
Range (current mode):
10 mA to 100 mAAC
Impedance (current mode):
20 Ω, typical
Overcurrent (current mode):
200 mAAC
Overvoltage (current mode):
60V rms
Frequency Range: 40 to 400 Hz,
factory calibrated at 60 Hz
Accuracy (including linearity,
hysteresis): ±0.1% of span, typical;
Humidity (Non-Condensing):
Operating: 15 to 95% (@45°C),
Soak: 90% for 24 hours (@65°C)
Temperature Range:
Operating: 0 to 55°C (32 to 131°F),
Storage: -25 to 70°C (-13 to 158°F)
* DRG-SC-DC-B has a ±5 V and ±10 V
output only
2
To Order, Call or Shop Online at omega.com
SM
Thermocouple Input Signal Conditioner
DRG-SC-TC, side view.
DRG-SC-TC, front view.
To Order
Model No. Description
DRG-SC-TC Thermocouple Input Signal Conditioner
DRN-PS-1000 Power supply, 95-240 Vac input,
24 Vdc output @ 1A
RAIL-35-1 35 mm (1.4") DIN rail, 1 m (3.3') length
RAIL-35-2 35 mm (1.4") DIN rail, 2 m (6.6') length
Comes complete with operator’s manual.
Ordering Example: DRG-SC-TC Thermocouple input signal conditioner.
Visit omega.com/drg-sc for Pricing and Details
DRG-SC-TC
The DRG-SC-TC is a DIN rail mount thermocouple
input signal conditioner. It can be field configured for
over 60 different thermocouple temperature ranges.
The output is linear to temperature and can be set for
either 0-5 V, 0-10 V, 0-1 mA, 0-20 mA or 4-20 mA. Zero
and span pots allow 50% adjustability of offset and
span turn down within each of the ranges. For example
the 500-1000°C range could be offset and turned down
to provide a 4-20 mA signal representing 750-1000°C.
Input Ranges
°C B E J K R/S T
-200 to 0 U U
-200 to 250 U U
-200 to 750 UU
-150 to 0 UU
-150 to -18
-150 to 250 UU
-150 to 400 U
-150 to 750 U
-18 to 125 UUUU
-18 to 250 UUUU
-18 to 400 U
-18 to 500 UUU
-18 to 750 U
-18 to 1000 UU
-18 to 1370 U
50 to 250 U
50 to 500 U
50 to 1000 U
50 to 1760 U
125 to 250 UUUUU
250 to 400 U
250 to 500 UUUU
375 to 400 U
375 to 500 UUUU
500 to 750 U
500 to 1000 UUUU
500 to 1820 U
750 to 1000 UUUU
1000 to 1370 U
1000 to 1760 U
1000 to 1820 U
1500 to 1760 U
1500 to 1820 U
To Order, Call or Shop Online at omega.com
SM
3
DC Input Signal Conditioner
DRG-SC-DC
The DRG-SC-DC is a DIN rail mount DC voltage
and current input signal conditioning module. The
input can be field configured for any one 12 voltage
ranges from 10 mV to 100 V or 6 current ranges from
1 mA to 100 mA. The output is linear to the input and
can be set to either 0-5 V, 0-10 V, 0-1 mA, 0-20 mA
or 4-20 mA for the DRG-SC-DC-U (unipolar outputs)
and -5 V to +5 V or -10 V to +10 V for the
DRG-SC-DC-B (bipolar outputs). Zero and span pots
allow 50% adjustability of offset and span turn down
within each of the ranges. For example the 0-2 mA
input range could be turned down to 0-1 mA and
provide a full scale output signal (e.g. 4-20 mA).
DRG-SC-DC-B DC voltage/current input signal conditioner with bipolar output ranges
DRG-SC-DC-U DC voltage/current input signal conditioner with unipolar output ranges
RAIL-35-1 35 mm (1.4") DIN rail, 1 m (3.3') length
RAIL-35-2 35 mm (1.4") DIN rail, 2 m (6.6') length
Comes complete with operator’s manual.
Ordering Example: DRG-SC-DC-U DC voltage/current input signal conditioner.
Visit omega.com/drg-sc for Pricing and Details
Bridge/Strain Gage Input Signal Conditioner
DRG-SC-BG
The DRG-SC-BG is a DIN rail mount bridge or strain
gage input signal conditioning module. The field
configurable input and output offers flexible, wide
ranging capability for bridge or strain gage applications
from 0.5 mV/V to over 50 mv/V. Wide ranging,
precision zero and span pots allow 50% adjustability
of offset and gain within each of the 11 switch
selectable input ranges. The output can be set for
either 0-5 V, 0-10 V, 0-1 mA, 0-20 mA or 4-20 mA. This
flexibility, combined with an adjustable (1 to 10 Vdc)
bridge excitation source, provides the user a reliable,
accurate instrument to isolate and condition virtually
any bridge or strain gage input.
Ordering Example: DRG-SC-BG bridge input signal conditioner.
Visit omega.com/drg-sc for Pricing and Details
4
To Order, Call or Shop Online at omega.com
SM
RTD Input Signal Conditioner
DRG-SC-RTD
The DRG-SC-RTD is a DIN rail mount RTD input
signal conditioning module. It accepts a wide variety
of RTDs including 100, 500 and 1000 Ohm Platinum
RTDs as well as 10, 25 and 100 Ohm copper.
It works with RTDs with a = 0.00385Ω/Ω/°C or
0.00392.Ω/Ω/°C
The input can be field configured for any one of up to
sixteen temperature ranges. The output is linear to
temperature and can be set for either 0-5 V, 0-10 V,
0-1 mA, 0-20 mA or 4-20 mA.
Input Ranges (°C):
PT100, PT500 and PT1000: -200 to 600, -200 to 400,
-100 to 400, -200 to 260, -200 to 0, -200 to -100,
-100 to 260, -100 to 100, -50 to 50, -18 to 50,
-18 to 100, -18 to 260, -18 to 300, -18 to 400,
-18 to 500, -18 to 600
Cu10, Cu25 and Cu100: -200 to 260,-200 to 0,
-200 to -100, -100 to 260, -100 to 100, -50 to 50,
-18 to 50, -18 to 100, -18 to 260
Frequency Input Signal Conditioner
DRG-SC-FR
The DRG-SC-FR is a DIN rail mount frequency input
signal conditioning module. The field configurable input
and output offers flexible, wide ranging capability for
a variable frequency drives, magnetic pickups, turbine
meters and other pulse or frequency output transducers.
The output can be set for either 0 to 5 V, 0 to 10 V,
0 to 1 mA, 0 to 20 mA or 4 to 20 mA. The DRG-SC-FR
can be configured for virtually any frequency input to
DC signal output within the ranges specified. Calibration
utilizes technology where the user simply applies
minimum and maximum input frequencies, touching a
recessed button to configure the minimum and maximum
output range.
INPUT RANGE: 2 Hz to 10,000 Hz, 50 mVp to 150 Vrms
To Order
Model No. Description
DRG-SC-RTD RTD Input Signal Conditioner
RAIL-35-1 35 mm (1.4") DIN rail, 1 m (3.3') length
RAIL-35-2 35 mm (1.4") DIN rail, 2 m (6.6') length
Comes complete with operator’s manual.
Ordering Example:DRG-SC-RTD RTD input signal conditioner.
To Order
Model No. Description
DRG-SC-FR Frequency Input Signal Conditioner
Comes complete with operator’s manual.
Ordering Example: DRG-SC-FR frequency input signal conditioner.
Visit omega.com/drg-sc for Pricing and Details
Visit omega.com/drg-sc for Pricing and Details
To Order, Call or Shop Online at omega.com
SM
5
Potentiometer Input Signal Conditioner
DRG-SC-PT
The DRG-SC-PT is a DIN rail mount potentiometer
input signal conditioning module.
The input provides a constant voltage and is designed
to accept any three-wire potentiometer from 100 Ω to
100 KΩ. The field configurable output can be set for
either 0-5 V, 0-10 V, 0-1 mA, 0-20 mA or 4-20 mA.
Wide ranging, precision zero and span pots, used in
conjunction with DIP switches, allow 80% adjustability
of offset and gain to transmit a full scale output from
any 20% portion of the potentiometer input.
INPUT RANGE:
100 Ω to 100 KΩ
To Order
Model No. Description
DRG-SC-PT Potentiometer Input Signal Conditioner
RAIL-35-1 35 mm (1.4") DIN rail, 1 m (3.3') length
RAIL-35-2 35 mm (1.4") DIN rail, 2 m (6.6') length
Comes complete with operator’s manual.
Ordering Example:DRG-SC-PT Potentiometer input signal conditioner.
AC Input Signal Conditioner
The DRG-SC-AC is a DIN rail mount AC input signal
conditioning module.
The field configurable input and output offers flexible
wide ranging capability for scaling, converting or
buffering AC inputs ranging from 5 mA to 100 mAAC
(for a greater input range, use optional current shunt,
DRG-C006) or 50 mV to 200 Vac. The DC output
of the DRG-SC-AC is proportional to the average of
the fully rectified AC input signal, and is calibrated
for sine waves between 40-400 Hz. The field
configurable output can be set for either 0-5 V, 0-10
V, 0-1 mA, 0-20 mA or 4-20 mA
The DRG-SC-AC has 15 input range switch settings.
Trim potentiometers allow 50% input and span
adjustability within each of the 15 full-scale input
ranges.
Visit omega.com/drg-sc for Pricing and Details
DRG-SC-AC
INPUT RANGES (INPUT SIGNAL FREQUENCY:
40 TO 400 HZ)
AC Voltage: 100 mV, 200 mV, 500 mV, 1 V, 2 V,
5 V,10 V, 20 V, 50 V, 100 V, 200 V
AC Current: 10 mA, 20 mA, 50 mA, 100 mA
To Order
Model No. Description
DRG-SC-AC AC Input Signal Conditioner
DRG-C006 0.1Ω, 5W Shunt Resistor
Comes complete with operator’s manual.
Ordering Example:DRG-SC-AC Potentiometer input signal conditioner.
6
Visit omega.com/drg-sc for Pricing and Details
To Order, Call or Shop Online at omega.com
SM
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.