DIN Rail Mount Signal Conditioners
DRG-SC Series
U Models Available for
Thermocouples, RTDs,
DC Voltage and Current,
Frequency, Strain Gage
Bridge, AC Voltage and
Current
U Field Configurable Input
and Output Ranges
U Five Field Configurable
Output Ranges: 0 to 5 V,
0 to 10 V, 0 to 1 mA,
0 to 20 mA and 4 to 20 mA
U Slim Housing Mounts on
DIN Rail for High Density
Installations
U 1800 Volts Isolation
Between Input, Output and
Power Supply
The DRG Series signal
conditioner modules accept a
wide variety of input signals such
as thermocouples, RTDs, strain
gages, DC voltages/currents,
AC voltages/currents, frequency
and potentiometers and produce a
proportional conditioned process
output. The inputs and outputs are
both field configurable and offer
flexible wide ranging capability.
The slim housing mounts on a DIN
rail and is ideal for high density
installation. All modules provide
1800 Vdc isolation between the
input, output and power supply.
Field Configurable
One advantage of the DRG series
is the field configurable input and
output ranges. Each module can
be set to a number of ranges by
dip switch selection. Wide
ranging precision zero and span
potentiometers provide even further
adjustment. The signal conditioners
may be set for an almost limitless
number of ranges. Range
adjustment requires the use of a
calibrator or reference source.
12.7
(0.496)
A/IN
STYLE A
A/OUT
OR
DIMENSIONS
ARE IN
MM (INCHES)
FRONT VIEW
STYLE B
17.7
(0.697)
110.2
32MM DIN RAIL
(4.34)
105.2
35MM DIN RAIL
(4.14)
88.5
(3.48)
SIDE VIEW - STYLE A or B
STYLE A OR B
DIMENSIONS
ARE IN
MM (INCHES)
90.0
(3.54)
To Order Visit omega.com/drg-sc for Pricing and Details
Model No. Description Case Style
DRG-SC-AC AC Voltage and Current A
DRG-SC-BG Strain Gage Bridge B
DRG-SC-DC-B DC Voltage and Current (bipolar) A
DRG-SC-DC-U DC Voltage and Current (unipolar) A
DRG-SC-FR Frequency A
DRG-SC-PT Potentiometer A
DRG-SC-RTD RTD B
DRG-SC-TC Thermocouple B
To Order, Call or Shop Online at omega.com
SM
1
Specifications
DRG-SC-AC
Range (voltage mode):
100 mV to 200 Vac
Impedance (voltage mode):
>100 KΩ
Overload (voltage mode):
300 Vac, max.
Range (current mode):
10 mA to 100 mAAC
Impedance (current mode):
20 Ω, typical
Overcurrent (current mode):
200 mAAC
Overvoltage (current mode):
60V rms
Frequency Range: 40 to 400 Hz,
factory calibrated at 60 Hz
Accuracy (including linearity,
hysteresis): ±0.1% of span, typical;
±0.5% of span, maximum.
Response Time: (10-90%)
250 mS., typical
Power: 9-30 Vdc, 1.5 W typical,
2.5 W max.
DRG-SC-BG
Range: 10 mV to ±200 mV
Impedance: >1 MΩ
Overvoltage: 400 VRMS max.
(intermittent); 264 VRMS, max.
(continuous)
Accuracy (including linearity,
hysteresis): ±0.1% typical, ±0.2%
max. of range @25°C
Bridge Excitation: 1 to 10 Vdc,
120 mA max.
Response Time: (10-90%)
<200 mS., typical
Power: 18-30 Vdc, 1.5 W typical,
2.5W max.(one 350Ω bridge), 4 W
max.(four 350Ω bridges)
DRG-SC-DC
Range (voltage mode): 10 mV to
100 V
Impedance (voltage mode):
> 100 KΩ
Overload (voltage mode):
400 VRMS, max.
Range (current mode): 1 mA to
100 mA
Impedance (current mode): 20 Ω,
typical
Overcurrent (current mode):
170 mA RMS max.
Overvoltage (current mode):
60 Vdc
Accuracy (including linearity,
hysteresis): <2 mA/20 mV:
±0.35% fs, typical; 0.5% max.;
>2 mA/20 mV:±0.1% fs typical,
0.2% max.
Response Time: (10-90%)
200 mS., typical
Power: 9-30 Vdc, 1.5 W typical,
2.5 W max
DRG-SC-FR
Frequency Range: 2Hz to
10,000 Hz
Amplitude Range: 50 mV to
150 VRMS
Accuracy (including linearity,
hysteresis): ±0.1% of selected
range
Impedance: >10 KΩ
Over-Voltage: 180 V rms, max.
Over-Range: 20 Khz, max.
Response Time: (10-90%):
500 mSec., or 100 times the period
of the full scale frequency.
Power: 9-30 Vdc, 1.5 W typical,
2.5 W max
DRG-SC-PT
Resistance (End to End): 100 Ω
up to 100 KΩ
Accuracy (including linearity,
hysteresis): ±0.1% maximum
@25°C
Input Impedance: >1 MΩ
Input Excitation: 500 mV, 5 mA
maximum drive
Response Time: (10-90%)
<200 mS., typical
DRG-SC-RTD:
Sensor Types: RTD, Pt100, Pt500,
Pt1000 (a = 0.00385 or 0.00392);
Cu10, Cu25, Cu100
Sensor Connection: 3 wire
Range: See Range Table
Accuracy (including linearity,
hysteresis): ±0.1% typical,
±0.2% max. the maximum input
temperature range @ 25°C, 0 Ω
lead resistance.
Excitation Current: <2 mA for
Pt100, Pt500, Pt1000; <5 mA for
Cu100; <10 mA for Cu10, Cu25
Leadwire Resistance: 40% of
base sensor resistance or 100 Ω
(whichever is less), max. per lead.
Leadwire Effect: Less than 1% of
the maximum input temperature
span.
Response Time: (10-90%)
200 mS., typical
Power: 9-30 Vdc
(DRG-SC-BG: 18-30 Vdc),
1.5 W typical, 2.5 W max
DRG-SC-TC
Sensor Types: J, K, T, R, S, E, B
Ranges: See Range Table
Accuracy:
J ±2°C (-200 to 750°C)
K ±5°C (-200 to -140°C)
±2°C (-140 to 1250°C)
±4°C (1250 to 1370°C)
E ±2.5°C (-150 to 1000°C)
T ±3°C (-150 to 400°C)
R & S ±6°C (50 to 1760°C)
B ±5°C (500 to 1820°C)
Bias Current (burnout detection):
<1.5 microamp
Impedance: >1 MΩ
Overvoltage: ±10 V differential
Response Time (10 to 90%):
500 mSec. Typical.
Power: 9-30 Vdc, 1.5 W typical,
2.5 W max
SPECIFICATIONS COMMON TO
ALL MODULES
Output*
Voltage Output:
Output: 0-5 V, 0-10 V
Impedance: <10 Ω
Drive: 10 mA max.
Current Output
Output: 0-1 mA, 0-20 mA,
4-20 mA
Compliance:
0-1 mA; 7.5 V, max.(7.5 KΩ)
0-20 mA: 12 V, max.(600 Ω)
4-20 mA: 12 V, max.(600 Ω)
Isolation: 1800 Vdc between input
output and power.
Mounting: Standard 32 mm or
35 mm DIN rail
ESD Susceptibility: Meets
IEC 801-2, level 2 (4 KV)
Humidity (Non-Condensing):
Operating: 15 to 95% (@45°C),
Soak: 90% for 24 hours (@65°C)
Temperature Range:
Operating: 0 to 55°C (32 to 131°F),
Storage: -25 to 70°C (-13 to 158°F)
* DRG-SC-DC-B has a ±5 V and ±10 V
output only
2
To Order, Call or Shop Online at omega.com