DIN Rail Mount Configurable Signal Conditioners
DRF Series
$
180
Basic Modules
⻬ Voltage, Current, Frequency, Resistance,
Potentiometer, Thermocouple, RTD
and Load Cell Input Modules
⻬ Field Configurable Signal Ranges
⻬ Provides up to 3500 Veff Isolation Between
Input and Output and Power (Isolation
is Model Specific)
⻬ Compatible with Standard
35 mm DIN Rail
The DRF series DIN rail signal conditioners are
designed to accept a broad range of input signals,
such as ac and dc voltage and current, frequency,
temperature (thermocouple and RTD), and process
transducers, and provide standard process outputs of
either 4 to 20 mA, or 0 to 10 Vdc. The DRF series
feature a modern housing design, that is easily
mounted on standard 35 mm DIN rails. Connections
are safely and securely made through pluggable
screw terminal connectors, with input and output
connections on the opposite sides of the module.
Functionality
The DRF series are designed to maximize
functionality. The front door of the housing provides
easy access to span and offset potentiometers
which may be used to field adjust the input and
output signal range.
Isolation
The input, output and power circuits are isolated by
3500 volts of galvanic isolation. The isolation protects
against potentially damaging voltages from passing
through the signal conditioners into connected
systems. The isolation also provides improved
measurement accuracy by minimizing the effects of
ground loops and electrical noise.
Outputs
Each DRF series signal conditioner is available with
current and voltage output (only one may be used at
a time). Available output types include 4 to 20 mA or
0 to 10 Vdc. Although pre-configured before shipping
from the factory, the output may be changed through
an internal jumper change.
Standard outputs are linear and proportional to the
signal input. Thermocouple input modules feature
special circuitry to linearize the output to the actual
temperature rather than the non-linear signal produced
by thermocouple sensors.
76
To Order, Callor Shop Online at omega.com
SM
SPECIFICATIONS
(Common to all Models)
Power: 24 Vdc ±10%, 230 Vac ±10% 50/60 Hz,
115 Vac ±10% 50/60 Hz
Power Consumption: <3.8 VA
Output: 4 to 20 mA and 0 to 10 Vdc
Maximum Voltage Output: 11 Vdc approx.
Minimum Voltage Output: -1 Vdc approx.
Minimum Load Resistance (Voltage): ‡1 K‰
Maximum Current Output: 22 mA approx.
Maximum Current Output: -1.5 mA approx.
Maximum Load Resistance (current): †400‰
Accuracy: <0.2% or <0.3% depending on model
Linearity: <0.1% or <0.2% depending on model
Thermal Drift: <150 ppm/°C or 250 ppm/°C typical
depending on model
Response Time: 70 mS (Process and DC input
models); 250 mS (Temperature and AC input models)
(DC Powered): 120 g (4.2 oz)
(AC Powered): 200 g (7 oz)
Dimensions:
(DC powered models):
110 H x 22.5 W x 93 mm D (4.3 x 0.9 x 3.7")
(AC powered models):
110 H x 37 W x 93 mm D (4.3 x 1.46 x 3.7")
Operating Temperature: 0 to 60°C (32 to 140°F)
Storage Temperature: -20 to 70°C (-4 to 158°F)
*Tested True RMS, 60 sec. leak <1 mA
To Order, Callor Shop Online at omega.com
SM
77
Thermocouple Input Signal Conditioner
DRF-TC
$
195
Basic Module
The DRF-TC thermocouple signal
conditioners accept thermocouple
input and provide a linearized and
isolated 0 to 10 Vdc or 4 to 20 mA
output. Models are available with
three different power options,
24Vdc, 120 Vac and 240 Vac.
The DRF-TC are ideally suited for
industrial applications. All models
⻬ Models for J, K, E, T, R
and S Thermocouples
⻬ Accuracy 0.3%
⻬ 250 ms Response Time
⻬ Upscale Break Protection
⻬ Linearized Output
⻬ Galvanic Isolation Between
Input, Output and Power
mount on a standard 35 mm DIN
rail and provide galvanic isolation
between input, output and power
up to 3500 Veff (model specific).
To insure maximum measurement
accuracy the units feature cold
junction compensation, 0.2%
linearity and less than 0.1˚C/1˚C
thermal drift due to compensation.
Module response time is 250 ms
or less.
Range Code Table
Range CodeRangeJKTERS
0/100C0 to 100°CX
0/150C0 to 150°CXX
0/175C0 to 175°CX
0/200C0 to 200°CX
0/250C0 to 250°CXX
0/300C0 to 300°CXX
0/400C0 to 400°CXXX
0/500C0 to 500°CX
0/700C0 to 700°CXX
0/800C0 to 800°CX
0/1200C0 to 1200°CX
0/1600C0 to 1600°CX
850/1700C850 to 1700°CX
Minimum Span*85°C85°C 100°C 85°C 100°C 100°C
* Custom ranges may be obtained by adjusting on-board zero and span potentiometers.
The minimum range is limited by the minimum span specification.
DRF-TCJ-115VAC-0/400C-4/20, $195,
shown larger than actual size
Specifications
Accuracy: <0.3% full scale
Linearity: <0.2% full scale
Thermal Drift: <250 ppm/°C typical
Thermocouple CJC Drift: 0.1°C/°C
Response Time: <250mS
(90% of signal)
Input Impedance: 1 M‰
Over Voltage Protection: 10 V
Thermocouple Input
78
ALL MODELS AVAILABLE FOR FAST DELIVERY!
To Order (Specify Model Number)
Model No.PriceDescription
DRF-TCJ-(*)-(**)-(***)$195Signal conditioner for J type thermocouple
DRF-TCK-(*)-(**)-(***)195Signal conditioner for K type thermocouple
DRF-TCT-(*)-(**)-(***)195Signal conditioner for T type thermocouple
DRF-TCE-(*)-(**)-(***)195Signal conditioner for E type thermocouple
DRF-TCR-(*)-(**)-(***)195Signal conditioner for R type thermocouple
Thermocouple
probe types:
J, K, E, T, R, S
(one model
for each
thermoucouple
type
To Order, Callor Shop Online at omega.com
DRF-TCS-(*)-(**)-(***)195Signal conditioner for S type thermocouple
CS-3767125Reference Book: Electrical
* Specify Power, 24 Vdc for 24 Vdc power, 115 Vac for 115 Vac power or 230 Vac
for 230 Vac power
** Specify range code from the Input Range Table
*** Specify output, 4/20 for 4 to 20 mA output or 0/10 for 0 to 10 Vdc output
Ordering Example: DRF-TCJ-115VAC-0/400C-4/20,
a J thermocouple with a 0 to 400°C input range, 4 to 20 mA output and 115 Vac power,
⻬ Upscale Break Protection
⻬ Response Time < 250 mS
⻬ Galvanic Isolation Between
Input, Output and Power
The DRF-RTD RTD signal
conditioners accept 2 or 3 wire
100 platinum RTDs as input and
provide an isolated 0 to 10 Vdc
or 4 to 20 mA output. Models are
available with three different power
options, 24 Vdc, 120 Vac and
240 Vac.
The DRF-RTD are ideally suited for
industrial applications. All models
mount on a standard 35 mm DIN
rail and provide galvanic isolation
between input, output and power
up to 3500 Veff (model specific).
Module response time is 250 mS
or less.
Specifications
RTD: 2 or 3 wire 100‰ platinum
RTD, ‰ =0.00385
Accuracy: <0.2% full scale
Linearity: <0.1% full scale
Thermal Drift: 250 ppm/°C typical
Response Time: <250mS
(90% of signal)
RTD Excitation: 1 Vdc
Input Impedance: Measured
with a “Wheatstone” bridge. Bridge
to positive through a 100‰
resistance, Bridge to negative
through a 10 K‰ resistance
3-Wire
RTD Input
2-Wire
RTD Input
Range Code Table
Range CodeRange
-25/75C-25 to 75°C
-50/150C-50 to 150°C
0/100C0 to 100°C
0/200C0 to 200°C
0/300C0 to 300°C
0/450C0 to 450°C
0/600C0 to 600°C
* Custom ranges may be obtained by adjusting
on-board zero and span potentiometers. The
minimum range is 0 to 50°C, maximum range
is 0 to 600°C (32 to 1112°F).
DRF-RTD-24VDC-0/100C-0/10,
$190, shown larger
than actual size
AVAILABLE FOR FAST DELIVERY!
To Order (Specify Model Number)
Model No.PriceDescription
DRF-RTD-(*)-(**)-(***)$190Signal conditioner for 100‰ Pt RTD
CS-377580Reference Book: Control
* Specify Power, 24 Vdc for 24 Vdc power, 115 Vac for 115 Vac power or 230 Vac
for 230 Vac power
** Specify range code from the Input Range Table
*** Specify output, 4/20 for 4 to 20 mA output or 0/10 for 0 to 10 Vdc output
Ordering Example: DRF-RTD-24VDC-0/100C-0/10,
RTD with a 0 to 100°C input range, 0 to 10 Vdc output and 24 Vdc power,
System Design Guide
signal conditioner for an
$190.
To Order, Callor Shop Online at omega.com
SM
79
Loading...
+ 7 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.