DRF-LC
FOR LOAD CELL INPUT
DRF Series Signal Conditioners
User’s Guide
OMEGAnet®On-Line Service Internet e-mail
omega.com info@omega.com
It is the policy of OMEGA Engineering, Inc. to comply with all worldwide safety and EMC/EMI regulations that apply.
OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add
the CE mark to every appropriate device upon certification.
The information contained in this document is believed to be correct, but OMEGA accepts no liability for any errors it
contains, and reserves the right to alter specifications without notice.
WARNING: These products are not designed for use in, and should not be used for, human applications.
Benelux:
Postbus 8034, 1180 LA Amstelveen
The Netherlands
Tel: +31 (0)20 3472121 FAX: +31 (0)20 6434643
Toll Free in Benelux: 0800 0993344
e-mail: sales@omegaeng.nl
Czech Republic:
Frystatska 184, 733 01 Karvina´, Czech Republic
Tel: +420 (0)59 6311899
FAX: +420 (0)59 6311114
Toll Free: 0800-1-66342
e-mail: info@omegashop.cz
France:
11, rue Jacques Cartier
78280 Guyancourt, France
Tel: +33 (0)1 61 37 2900 FAX: +33 (0)1 30 57 5427
Toll Free in France: 0800 466 342
e-mail: sales@omega.fr
Servicing Europe:
U.S.A. and Canada:
Sales Service: 1-800-826-6342 / 1-800-TC-OMEGA
®
Customer Service: 1-800-622-2378 / 1-800-622-BEST
®
Engineering Service: 1-800-872-9436 / 1-800-USA-WHEN
®
TELEX: 996404 EASYLINK: 62968934
CABLE: OMEGA
U.S.A.: ISO 9001 Certified
One Omega Drive, Box 4047
Stamford, CT 06907-0047
Tel: (203) 359-1660
FAX: (203) 359-7700
e-mail: info@omega.com
Servicing North America:
For immediate technical or application assistance:
Mexico:
En Espan~ol: (001) 203-359-7803
FAX: (001) 203-359-7807
e-mail: espanol@omega.com
info@omega.com.mx
Germany/Austria:
Daimlerstrasse 26, D-75392
Deckenpfronn, Germany
Tel: +49 (0)7056 9398-0
FAX: +49 (0)7056 9398-29
Toll Free in Germany: 0800 639 7678
e-mail: info@omega.de
United Kingdom: ISO 9002 Certified
One Omega Drive
River Bend Technology Centre
Northbank, Irlam
Manchester M44 5BD
United Kingdom
Tel: +44 (0)161 777 6611
FAX: +44 (0)161 777 6622
Toll Free in United Kingdom:
0800-488-488
e-mail: sales@omega.co.uk
Canada:
976 Bergar
Laval (Quebec) H7L 5A1, Canada
Tel: (514) 856-6928
FAX: (514) 856-6886
e-mail: info@omega.ca
User’s Manual Series DRF
0-INDEX___________________________________________________
1-GENERAL INFORMATION.................................. 4
2-INSTALLATION ................................................... 5
3-DIMENSIONS AND CONNECTIONS................... 6
4-SIGNAL INPUT JUMPERS and PREOFFSET ..... 7
5-SIGNAL OUTPUT JUMPERS .............................. 8
6-READJUSTING INPUT/OUTPUT ......................... 8
7-TECHNICAL DATA-I ............................................ 9
INPUT SIGNAL for mVdc ........................... 9
OUTPUT SIGNAL in Vdc ........................... 9
OUTPUT SIGNAL in mA ............................ 9
IMPEDANCES AND OVERVOLTAGES .... 9
POWER SUPPLY ..................................... 9
MECHANICAL DIMENSIONS .................... 9
GALVANIC ISOLATION ............................. 9
GENERAL SPECIFICATIONS ................... 9
MATERIALS .............................................. 9
8-CAUTIONS, WARNINGS AND NOTES ............... 10
SAFETY CONSIDERATIONS
PRESCRIPTION.- Before starting any
operation for replacement, maintenance or
assure good functioning and performance.
To prevent electrical or fire hazard, do not
expose the unit to excessive moisture. Do not
operate the unit in the presence of flammable
gases or fumes, such an environment
definetely constitutes a safety hazard. The
unit is designed to be mounted on a metal
panel.
repair, the unit must be
disconnected from any kind
of power supply.
Keep the unit clean, to
If the unit shows signs of damage, is not able
to show the expected measures, has been
stored in a bad conditions or a protection
failure happened, then do not attempt to
operate, keep the unit out of service and send
for repair.
IN CASE OF FIRE
1.- Disconnect the unit from the power supply
2.- Give the alarm according to the local rules
3.- Switch off all air conditioning devices
WARNING: In closed areas do not use
systems with vaporized liquids.
4.- Attack the fire with carbonic
snow, do not use water in any
case
Page 3
User’s Manual Series DRF
1-GENERAL INFORMATION___________________________________
The DRF series of Isolated Signal Converters,
allow to convert process signals,
temperatures, electrical signals, etc, to current
loops or voltage signals for further
retransmision, while introducing into the
system galvanic isolation barriers between
the input, the output and the power supply
circuits.
The DRF series of Isolated Signal Converters,
offer an excellent relation between signal
conversion speed and measurement
accuracy. Offering a 0.2% accuracy and up
to a 70ms response time depending on the
model, these units can process information
coming from probes or transducers, in such
a way that can be quickly retransmitted in a
fast and accurate form to remote data
acquisition systems or PLC’s. The isolated
signal converters of the ISC series are ideal
to integrate into 12 bit data acquisition
systems.
Its powerful galvanic isolation of 3.500 V
introduces high security to the measuring
systems, preventing the propagation of those
phenomenon which usually cause damage
to the remote system, such as transient
peaks or energy shocks in any of the circuits
of the system. The galvanic isolation also
acts as a strong CE barrier. The decoupling
created between the input, output and power
circuits avoids pernicious effects on the
output, such as ground loops or signal leaks,
which distort the acquired data and are
extremely difficult to isolate once introduced
into the signal.
The isolation offered by the DRF series of
Isolated Signal Converters is a 3 way
isolation. Thus, all the benefits exposed
above are applicable to any of the three
circuits composing the instrument : input,
output and power.
Recalibration of the instruments is realized
in a fast and easy way. Opening the front
cover grants access to the configuration
jumpers. Additional Span and Offset
potentiometers are directly accessible from
the frontal part. These potentiometers are
highly decoupled, minimizing the iterations
needed to obtain a correct adjustment.
In order to obtain a higher and quickest
benefit of the DRF units, we recommend you
to read carefully the information provided in
this manual before proceeding to the
installation of the instrument. In this manual
you will find all technical data, both electrical
and mechanical, needed for a correct
instalation and utilization.
Note : The DRF Isolated Signal Converter
instruments have a characteristics label
attached on the side of the instrument. Check
that the information indicated on the label
matches with your application requirements,
and specially check that the value and type of
the power supply needed matches the value
and type of the power supply availble on your
installation.