Omega Products DP9601 User Manual

High Precision Digital RTD Thermometer/Data Logger
With USB Port
DP9601 Series
U Reference Standard Thermometer
for Pt100 Sensors
System Accuracy
U Simple, Fast Digital Matching to
Calibrated Sensors, Up to 10 Points Per Channel Retained in Memory
U Alpha Numeric Display U Resolution 0.01ºc for Pt100 Inputs U Data Logging U Wide Temperature Range U Readout Directly In ºC, ºF, K, Ω U Two Sensor Input Ports U Channel A, B or A-B Reading U USB Serial Communications U USB Flash Drive Port U Supplied with PC Software U Programmable Analog
Retransmission Output
U Rechargeable Lithium Ion Battery/
Mains Powered
DP9601 shown smaller than actual size.
The DP9601 provides precise platinum resistance thermometer temperature measurement and logging for exacting applications in both laboratory and site locations. It is an exceptionally accurate and stable digital thermometer particularly suitable for use with thermal calibration baths as a reference standard. Applications include medical, pharmaceutical, food, environmental testing, R&D and educational establishments.
Displayed values and user information are indicated on a bright clear LED screen with diffused backlighting. Data can be displayed in °C, °F, K, Ω as required; nine front panel push keys, the only user controls, are used in conjunction with the display screen. It is this arrangement which makes for very simple and “friendly” operation.
There are two input ports for 3- or 4-wire Pt100 sensors; the instrument automatically recognizes 3- or 4-wire configurations. The measured temperature can be displayed directly from one of the inputs or differentially between the two inputs. Differential temperature and the two individual channel temperatures are displayed simultaneously.
A flash drive USB port is provided to allow data to be stored and/or exported. PC software running in Windows® is provided as standard; it allows programming of custom calibration, remote control and measure and logging functions.
K-1
K
Specifications
Inputs/Ranges/Sensors Type: Pt100 to IEC 751 (ITS 90 refers) -200 to 850ºC
(-328 to 1562ºF) R automatic recognition (with manual override)
Overall Accuracy: ±0.01ºC ±0.0005% of span Linearisation Conformity: Better than ±0.01ºC Stability (vs Ambient Temperature): Better than 0.0025ºC
per 1ºC ambient change Warm-Up: Negligible under normal ambient conditions.
Allow 5 to 10 minutes for full stability unless stored at low temperature, then 30 minutes minimum
Pt100 Sensor Current: 0.5 mA Resolution of Data Display: 0.01 Variable Filter: Sampling rate selectable between 4 and 64
(measurements averaged per reading)
Measurement Units: °C, °F, K, Ω Measurement Modes: A, B or A-B Custom Calibration: Up to 10 calibration values can be
allocated to Pt100 input A & B; values are retained in non-volatile memory until replaced by user; ITS 90 or IPTS 68 coefficients can be used for custom calibration
Smart Sensor Connection: Correction values stored in connector
Null Function: Corrects differential temperature readout between two sensors to zero
Sensor Lead Resistance: 5 Ω each lead maximum Logging: 8000 readings Supply: Internal lithium Ion rechargeable batteries; mains
90 to 260V 50/60 Hz universal adaptor included; battery charge life up to 12 hours with full charge.
= 100 Ω 3- or 4-wire connection with
o
Series Mode Rejection: 60 dB @ 50 Hz (50 mV RMS applied)
Common Mode Rejection: 30V RMS applied between input and earth produces no measurable effect
Display: 128 x 64 pixel character OLED screen with diffused backlighting; wide viewing angle, high contrast (adjustable)
Front Panel Controls: 9 membrane push-keys to control all instrument functions
Mechanical/Case: Metal bench top case/adjustable tilt Dimensions: Overall 190 W x 70 H x 250 mm D
(7.5 x 2.75 x 9.85")
Weight: 3 kg (6.61 lb) approx Input Connections: 2 x Pt100 via D type connectors USB Serial: Isolated, 9600 Baud, 8 data, no parity,
1 stop bit
Communications: Remote control and measure PC Software (Standard): Supplied as standard on
CD-ROM. Remote control and measure: log readings to file/ download to PC/programming corrections
Analog Output (Standard): User programmable, 0 to 5V
Application Note: Inputs are not isolated in the instrument, which is primarily designed for laboratory applications and site calibration of industrial temperature sensors. Probes connected to the instrumentmust therefore be isolated from high voltage pick-up.
Precision Pt100 Probes: 304 Stainless steel probes, 6 mm Dia. with 2 m screened PTFE lead Pt100 Probes and connector
DP9600-L250: 250 mm (9.85") L, -50 to 250ºC (-58 to 482ºF)
DP9600-H450: 350 mm (13.75") L, -50 to 450ºC (-58 to 842ºF)
SM
OMEGACARESM extended warranty program is available for models shown on this page. Ask your sales representative for full details
Extended Warranty
Program
when placing an order. OMEGACARESM covers parts, labor and equivalent loaners.
To Order Visit omega.com/dp9601 for Pricing and Details Model No. Description DP9601 High precision digital RTD thermometer
Accessories Model No. Description
DP9600-L250 Precision PT100 RTD probe, -50 to 250ºC, (-58 to 482ºF), 250 mm (9.85")
DP9600-H450 Precision PT100 RTD probe, -50 to 450ºC, (-58 to 842ºF), 350 mm (13.75")
DP9600-INSTRUMENT-CAL Calibration for instrument alone (no NIST)
DP9600-SYS-CAL Calibration of instrument and sensor together at five points (no NIST)
DP9600-SYS-COR-CAL Calibration of instrument and sensor together at five points, after initial calibration of
sensor only and programming of corrections (no NIST)
DP9600-TBLK4 Terminal block for connection of 3- or 4-wire Pt100s
Comes complete with software, power adaptor, 9-pin connector and operator’s manual.
Ordering Example: DP9601, high precision digital RTD thermometer, DP9600-H450 probe. OCW-2, OMEGACARESM extends standard 1-year warranty to a total of 3 years.