K-40
Supplied with calibration cable, 9 V battery, carrying case, NIST Certificate, protective rubber
boot and complete operator’s manual.
Ordering Example: CL28MA simulator, meter, $495. OCW-1 OMEGACARESMextends
standard 3-year warranty to a total of 4 years ($49), $495 + 49 = $544.
See Section M
for Process
Indicators
Milliamp Calibrator
NIST Traceable
Simulates and Measures
0 to 21 mA
±0.05 % of Range
Ramp/Step Function
Simulates 2-Wire
Transmitters
Reads mA or Percent
Combination milliamp simulator
and meter has numerous
pre-programmed operating modes
making this a versatile and
time-saving instrument. It has
user-programmable setups backed
up with non-volatile memory for
repeated special tests. Both the
simulation and measurement
modes operate with external
loop power supplies or with an
internal 24 V power source.
The CL28MA can be programmed
with either mA or percent-of-scale
data. When operating, the unit can
toggle between mA or percent
modes with the touch of one button.
Instead of fuses, the CL28MA is
protected with PTC resistors. These
devices automatically reset when
a fault condition is corrected.
Protection is provided between any
combination of terminations in the
input and output connectors.
Specifications
Simulator Output and Measure Input
Connectors: Female SMP
Simulator Output and Measure Input
Current: 0.00 to 21.00 mA
Accuracy (64°F to 82°F ambient,
1 year): ±0.05% of range
Temp. Coefficient: 64 to 82°F;
included in accuracy specifications;
from 14 to 64°F and 82 to 122°F;
±0.0015% of range per °F
SIMULATOR SELECTIONS
Range: 0.00 to 21.00 mA/0.0% to
105.0%; 4.00 to 21.00 mA/0.0% to
106.3%
Loop Power Source: External:
(56 Vdc max.); Internal: (24 Vdc nom.)
Fixed Outputs: Keypad entered and
memory recalled value/power source
(5 locations)
Pre-Set Ramp/Step Outputs
4:1 Linear Steps: 4, 8, 12, 16,
20 mA (4-20 mA); 0, 5, 10, 15,
20 mA (0-20 mA)
4.2 Square Root Steps: 4, 5, 8, 12,
20 mA (4-20 mA); 0, 12.5, 5, 11.25,
20 mA (0-20 mA)
User-Programmed Ramp/Step
Outputs (5 memory locations):
Step size, start point, high limit,
low limit, dwell time
Ramp Stepping: Manual and automatic
NiCd: Approx.
1
⁄4 life of alkaline battery
Error Messages: LO (under range
current), HI (over range current),
-POL (input current reversed),
and OL (output loop overload)
Operating Temp. Range:
-10 to 50°C (14 to 122°F),
<90% RH; reduce RH by 1.7%/°F
from 95 to 122°F
Storage Temp. Range: -22 to 60°C
(-30 to 140°F), <95% RH up to 95°F,
reduce RH limit by 1.7%/°F
from 95 to 140°F
Dimensions:
17.8 H x 7.4 W x 2.8 cm D
(7.0 x 2.9 x 1.1")
Weight: 284 g (10 oz)
MEASURE SELECTIONS
Range:
0.00 to 21.00 mA/0.0% to 105.0%;
4.00 to 21.00 mA/0.0% to 106.3%
Loop Power Source: External
(56 Vdc); internal (24 Vdc nom.)
Store/Recall Measurements:
5 memory locations
Run/Hold
Simulator Drive Capability:
900 ohms max.
Measure Input Resistance:
10 ohm shunt in series with 1Ω (nom.)
PTC resistor for overload protection
Power: 9 V alkaline battery (supplied),
lithium, or NiCd (rechargeable) battery
Battery Life, Continuous:
Alkaline: External loop: 30 hrs typical.
Internal loop: (12 mA) 7 hrs typical;
(20 mA) 4 hrs typical
Lithium:
Approx. twice life of alkaline battery
To Order (Specify Model No.) IN STOCK FOR FAST DELIVERY
Model Number Price Description
CL28MA $495 0-21 mA Simulator/Meter
K
OMEGACARESMextended warranty program
is available for models shown on this page.
Ask your sales representative for full details
when placing an order.
Shown smaller than
actual size, scaling
the Model DP24-E
Process Indicator
Model CL28MA
$
495