Omega Products CL230 Installation Manual

TEMPERATURE
✭✵
Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies
✭✵
Wire: Thermocouple, RTD
✭✵
✭✵
Calibrators & Ice Point
✭✵
References
✭✵
Recorders, Controllers &
✭✵
Process Monitors
✭✵
Infrared Pyrometers
PRESSURE, STRAIN AND FORCE
Transducers & Strain
✭✵
Gauges
✭✵
Load Cells & Pressure
✭✵
Gauges
✭✵
Displacement Transducers
✭✵
Instrumentation &
✭✵
Accessories
FLOW/LEVEL
Rotameters, Gas Mass Flowmeters & Flow Computers
✭✵
Air Velocity Indicators
✭✵
Turbine/Paddlewheel
✭✵
Systems
✭✵
Totalizers & Batch
✭✵
Controllers
pH/CONDUCTIVITY
pH Electrodes, Testers &
Accessories
✭✵
Benchtop/Laboratory
✭✵
Meters
✭✵
Controllers, Calibrators, Simulators & Pumps
✭✵
Industrial pH &
✭✵
Conductivity Equipment
DATA ACQUISITION
Data Acquisition & Engineering Software
✭✵
Communications-Based Acquisition Systems
✭✵
Plug-in Cards for Apple, IBM & Compatibles
✭✵
Datalogging Systems
✭✵
Recorders, Printers &
✭✵
Plotters
HEATERS
✭✵
Heating Cable
✭✵
Cartridge & Strip Heaters
✭✵
Immersion & Band Heaters
✭✵
Flexible Heaters
✭✵
Laboratory Heaters
ENVIRONMENTAL MONITORING AND CONTROL
✭✵
Metering & Control Instrumentation
✭✵
Refractometers
✭✵
Pumps & Tubing
✭✵
Air, Soil & Water Monitors
✭✵
Industrial Water & Wastewater Treatment
✭✵
pH, Conductivity & Dissolved Oxygen Instruments
Where Do I Find Everything I Need
for Process Measurement and Control?
OMEGA …Of Course!
M3125/0798
http://www.omega.com
e-mail: info@omega.com
CL230
Hand-Held
RTD Calibrator
OMEGAnetSMOn-Line Service Internet e-mail
http://www.omega.com info@omega.com
It is the policy of OMEGA to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification. The information contained in this document is believed to be correct but OMEGA Engineering, Inc. accepts no liability for any errors it contains, and reserves the right to alter specifications without notice.
WWAARRNNIINNGG::
These products are not designed for use in, and should not be used for, patient con-
nected applications.
Benelux:
Postbus 8034, 1180 LA Amstelveen, The Netherlands Tel: (31) 20 6418405 FAX: (31) 20 6434643 Toll Free in Benelux: 06 0993344 e-mail: nl@omega.com
Czech Republic:
ul. Rude armady 1868, 733 01 Karvina-Hranice, Czech Republic Tel: 420 (69) 6311627 FAX: 420 (69) 6311114 e-mail: czech@omega.com
France:
9, rue Denis Papin, 78190 Trappes Tel: (33) 130-621-400 FAX: (33) 130-699-120 Toll Free in France: 0800-4-06342 e-mail: france@omega.com
Servicing Europe:
USA and Canada:
Sales Service: 1-800-826-6342 / 1-800-TC-OMEGA
SM
Customer Service: 1-800-622-2378 / 1-800-622-BEST
SM
Engineering Service: 1-800-872-9436 /
1-800-USA-WHEN
SM
TELEX: 996404 EASYLINK: 62968934
CABLE: OMEGA
USA: ISO 9001 Certified
One Omega Drive, Box 4047 Stamford, CT 06907-0047 Tel: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com
Servicing North America:
For immediate technical or application assistance:
Mexico and Latin America:
Tel: (95) 800-TC-OMEGA
SM
FAX: (95) 203-359-7807 En Espan~ol: (203) 359-7803 e-mail: espanol@omega.com
Germany/Austria:
Daimlerstrasse 26, D-75392 Deckenpfronn, Germany Tel: 49 (07056) 3017 FAX: 49 (07056) 8540 Toll Free in Germany: 0130 11 21 66 e-mail: germany@omega.com
United Kingdom: ISO 9002 Cer
tified
•25 Swannington Road, Broughton Astley, Leicestershire, LE9 6TU, England Tel: 44 (1455) 285520 FAX: 44 (1455) 283912
•P.O. Box 7, Omega Drive, Irlam, Manchester, M44 5EX, England Tel: 44 (161) 777-6611 FAX: 44 (161) 777-6622
Toll Free in England: 0800-488-488 e-mail: uk@omega.com
Canada:
976 Bergar Laval (Quebec) H7L 5A1 Tel: (514) 856-6928 FAX: (514) 856-6886 e-mail: canada@omega.com
FOR WARRANTY RETURNS, please have the following information available BEFORE contacting OMEGA:
1. P.O. number under which the product was PURCHASED,
2. Model and serial number of the product under warranty, and
3. Repair instructions and/or specific problems relative to the product.
FOR NON-WARRANTY REPAIRS,
consult OMEGA for current repair charges. Have the following information available BEFORE con­tacting OMEGA:
1. P.O. number to cover the COST of the
repair,
2. Model and serial number of product, and
3. Repair instructions and/or specific
problems relative to the product.
OMEGA’s policy is to make running changes, not model changes, whenever an improvement is pos­sible. This affords our customers the latest in technology and engineering.
OMEGA is a registered trademark of OMEGA ENGINEERING, INC.
© Copyright 1996 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without prior written consent of OMEGA ENGINEERING, INC.
WARRANTY/ DISCLAIMER
OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA Warranty adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA’s customers receive maximum coverage on each product.
If the unit should malfunction, it must be returned to the factory for evaluation. OMEGA’s Customer Service Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective it will be repaired or replaced at no charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unautho­rized modification. This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of being damaged as a result of excessive corrosion; or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating conditions outside of OMEGA’s control. Components which wear are not warranted, including but not limited to contact points, fuses, and triacs.
OMEGA is pleased to offer suggestions on the use of its various products. However, OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by it will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive and the total liability of OMEGA with respect to this order, whether based on contract, warranty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event shall OMEGA be liable for consequential, incidental or special damages.
CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical applications or used on humans. Should any Product(s) be used in or with any nuclear installation or activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility as set forth in our basic WARRANTY/ DISCLAIMER language, and additionally, purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product(s) in such a manner.
RETURN REQUESTS/ INQUIRIES
Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE RETURNING ANY PRODUCT(S) TO OMEGA , PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return package and on any correspondence.
The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in transit.
✓ ✓
✓ ✓ ✓ ✓ ✓
✓ ✓ ✓ ✓
✓ ✓
✓ ✓
User’s Guide
MAINTENANCE
Generally, with normal usage, this calibrator should hold its rated specifications for at least 12 months. Beyond this, it should remain within
1.5X of its specification over its useful life, provided it is not abused or tampered with. If after the stated warranty period, the device falls out of calibration, it can be returned to Omega for re-calibration. Please call 1-800-826-6342 for pricing and return information.
GENERAL DESCRIPTION
The CL230 is designed to be a simple to use, high accuracy RTD Calibrator capable of either simulating or reading several common RTD Types. When being used as an RTD simulator the CL230 can calibrate a wide range of RTD Transmitters and recording devices due to its low excitation current capability. The step and scroll keys allow the user to make output changes quick and easily.
INSTALLATION
UNPACKING
Remove the Packing List and verify that all equipment has been received. If there are any questions about the shipment, please call Omega’s Customer Service Dept. at 1-800-826-6342.
When you receive the shipment, inspect the container and equipment for any signs of damage. Note any evidence of rough handling in transit. Immediately report any damage to the shipping agent.
NOTE
The carrier will not honor any claims unless all shipping material is saved for their examination. After examining and removing contents, save packing material and carton in the event reshipment is necessary.
SET-UP
Before beginning, become familiar with the keypad layout and the configuration of the input/output jacks. Remember, these jacks are used in multiple configurations so pay careful attention to the jack identification label on back of unit and how the test leads are connected for the specific application.
OPERATING PROCEDURE
1. Turn on power and select desired RTD type by depressing the Range key. Once the desired range has been selected it will remain in memory until a new range is selected.
2. Select either input or output by depressing the In/Out key.
NOTE: The display will read “OPEN” if the unit is not connected to either an RTD or RTD measuring device.
3. Connect the CL230 to the device under test as shown in the operating modes section.
4. If you are using the CL230 in the output mode use the Step or Scroll keys to set output.
The Step key will step in 100° increments and the Scroll key allows single degree increments which will increase in speed if the switch is depressed for several seconds.
OPERATING MODES
1. RTD Simulation Mode
One of the most common uses of the CL230 is for simulating an RTD when calibrating an RTD measur­ing device such as a transmitter, data logger, PLC or similar product. To understand how to calibrate an RTD measuring device, it’s important to have a gen­eral understanding of how an RTD operates.
By design, an RTD is a resistive sensor which changes its resistance value (ohms) as a function of tempera­ture. Unlike a thermocouple, it does not “put out” a voltage or current but is strictly a passive device. Because of this, a current must be passed through the RTD so that a voltage can be developed across the
RTD and then amplified by the measuring device. Ohm’s Law is a simple algebraic expression which describes the relations between voltage, current and resistance.
Ohm’s Law states: V = I x R where V = Voltage, I = Current, R = Resistance
From this equation, we can see that the voltage devel­oped across the RTD is equal to the current traveling through it times its resistance. Therefore, for a fixed current, the voltage measured will be directly propor­tional to the temperature.
Figure 1 illustrates a typical example of how an RTD transmitter measures an RTD sensor using a fixed current.
Figure 1
In this example a two-wire RTD transmitter is being calibrated using the CL230 in the simulation mode. The transmitter under test supplies an excitation cur­rent into the calibrator and the calibrator adjusts the voltage drop at the terminals to yield the desired resistance for a given temperature. For the CL230 to operate properly the excitation current must be in the range of 0.125mA to 2mA and the polarity must be correct. Too low of excitation current or pulsed excita­tion current will be indicated by the word “OPEN”
flashing on the display. Reverse polarity will be indi­cated by “REV.POL” on the display. If your device requiring calibration has a pulsed excitation current refer to the PTC-9002.
The example in Figure 1 shows an RTD Transmitter with the RTD sensor having two connection points. In many cases, however, RTD devices have 3 and 4 wire connections. Figures 2 and 3 illustrate the proper connection procedure.
Figure 2
Figure 3
In both of these examples a jumper(s) must be made at the device under test for the circuit to work properly. The proper connections for these jumpers are generally shown by the label or silkscreen on the device under test. If proper RTD connections are not obvious refer to instruction manual for the device under test.
2. RTD Read Mode
The CL230 can also be used to read an RTD probe or similar RTD sensor. The CL230 only works in the 4 wire mode; however, 2 and 3 wire RTD's can be read as long as multiple connections are made at the RTD loads. Refer to the label on the rear of the CL230 for connection information.
SPECIFICATIONS
Ranges PT385 -200 to 850°C
PT392 -200 to 850°C Ni120 -80 to 320°C Jis.392 -200 to 850°C
Resolution 1°C or 1°F
Accuracy ±1°C
Excitation Current Range (Source Mode) 0.125 to 2.0mA continuous
Operating Temp. 0 to 50°C
Storage Temp. -20 to 60°C
Temperature Coef. ±.01% F.S./°C
Power
1
9V alkaline battery
Case Size 1.43” x 3.15” x 5.7”
Weight 12 oz.
Notes: 1 A low battery indication is given at 5.5 volts.
Loading...