Omega Products CL220 Installation Manual

TEMPERATURE
✭✵
Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies
✭✵
Wire: Thermocouple, RTD
✭✵
✭✵
Calibrators & Ice Point
✭✵
References
✭✵
Recorders, Controllers &
✭✵
Process Monitors
✭✵
Infrared Pyrometers
PRESSURE, STRAIN AND FORCE
Transducers & Strain
✭✵
Gauges
✭✵
Load Cells & Pressure
✭✵
Gauges
✭✵
Displacement Transducers
✭✵
Instrumentation &
✭✵
Accessories
FLOW/LEVEL
Rotameters, Gas Mass Flowmeters & Flow Computers
✭✵
Air Velocity Indicators
✭✵
Turbine/Paddlewheel
✭✵
Systems
✭✵
Totalizers & Batch
✭✵
Controllers
pH/CONDUCTIVITY
pH Electrodes, Testers &
Accessories
✭✵
Benchtop/Laboratory
✭✵
Meters
✭✵
Controllers, Calibrators, Simulators & Pumps
✭✵
Industrial pH &
✭✵
Conductivity Equipment
DATA ACQUISITION
Data Acquisition & Engineering Software
✭✵
Communications-Based Acquisition Systems
✭✵
Plug-in Cards for Apple, IBM & Compatibles
✭✵
Datalogging Systems
✭✵
Recorders, Printers &
✭✵
Plotters
HEATERS
✭✵
Heating Cable
✭✵
Cartridge & Strip Heaters
✭✵
Immersion & Band Heaters
✭✵
Flexible Heaters
✭✵
Laboratory Heaters
ENVIRONMENTAL MONITORING AND CONTROL
✭✵
Metering & Control Instrumentation
✭✵
Refractometers
✭✵
Pumps & Tubing
✭✵
Air, Soil & Water Monitors
✭✵
Industrial Water & Wastewater Treatment
✭✵
pH, Conductivity & Dissolved Oxygen Instruments
Where Do I Find Everything I Need
for Process Measurement and Control?
OMEGA …Of Course!
M3124/0798
http://www.omega.com
e-mail: info@omega.com
CL220
Hand-Held
Thermocouple Calibrator
OMEGAnetSMOn-Line Service Internet e-mail
http://www.omega.com info@omega.com
It is the policy of OMEGA to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification. The information contained in this document is believed to be correct but OMEGA Engineering, Inc. accepts no liability for any errors it contains, and reserves the right to alter specifications without notice.
WARNING: These products are not designed for use in, and should not be used for, patient con­nected applications.
Benelux:
Postbus 8034, 1180 LA Amstelveen, The Netherlands Tel: (31) 20 6418405 FAX: (31) 20 6434643 Toll Free in Benelux: 06 0993344 e-mail: nl@omega.com
Czech Republic:
ul. Rude armady 1868, 733 01 Karvina-Hranice, Czech Republic Tel: 420 (69) 6311627 FAX: 420 (69) 6311114 e-mail: czech@omega.com
France:
9, rue Denis Papin, 78190 Trappes Tel: (33) 130-621-400 FAX: (33) 130-699-120 Toll Free in France: 0800-4-06342 e-mail: france@omega.com
Servicing Europe:
USA and Canada:
Sales Service: 1-800-826-6342 / 1-800-TC-OMEGA
SM
Customer Service: 1-800-622-2378 / 1-800-622-BEST
SM
Engineering Service: 1-800-872-9436 /
1-800-USA-WHEN
SM
TELEX: 996404 EASYLINK: 62968934
CABLE: OMEGA
USA: ISO 9001 Certified
One Omega Drive, Box 4047 Stamford, CT 06907-0047 Tel: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com
Servicing North America:
For immediate technical or application assistance:
Mexico and Latin America:
Tel: (95) 800-TC-OMEGA
SM
FAX: (95) 203-359-7807 En Espan~ol: (203) 359-7803 e-mail: espanol@omega.com
Germany/Austria:
Daimlerstrasse 26, D-75392 Deckenpfronn, Germany Tel: 49 (07056) 3017 FAX: 49 (07056) 8540 Toll Free in Germany: 0130 11 21 66 e-mail: germany@omega.com
United Kingdom: ISO 9002 Cer
tified
•25 Swannington Road, Broughton Astley, Leicestershire, LE9 6TU, England Tel: 44 (1455) 285520 FAX: 44 (1455) 283912
•P.O. Box 7, Omega Drive, Irlam, Manchester, M44 5EX, England Tel: 44 (161) 777-6611 FAX: 44 (161) 777-6622
Toll Free in England: 0800-488-488 e-mail: uk@omega.com
Canada:
976 Bergar Laval (Quebec) H7L 5A1 Tel: (514) 856-6928 FAX: (514) 856-6886 e-mail: canada@omega.com
FOR WARRANTY RETURNS, please have the following information available BEFORE contacting OMEGA:
1. P.O. number under which the product was PURCHASED,
2. Model and serial number of the product under warranty, and
3. Repair instructions and/or specific problems relative to the product.
FOR NON-WARRANTY REPAIRS,
consult OMEGA for current repair charges. Have the following information available BEFORE con­tacting OMEGA:
1. P.O. number to cover the COST of the
repair,
2. Model and serial number of product, and
3. Repair instructions and/or specific
problems relative to the product.
OMEGA’s policy is to make running changes, not model changes, whenever an improvement is pos­sible. This affords our customers the latest in technology and engineering.
OMEGA is a registered trademark of OMEGA ENGINEERING, INC.
© Copyright 1996 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without prior written consent of OMEGA ENGINEERING, INC.
WARRANTY/ DISCLAIMER
OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA Warranty adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA’s customers receive maximum coverage on each product.
If the unit should malfunction, it must be returned to the factory for evaluation. OMEGA’s Customer Service Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective it will be repaired or replaced at no charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unautho­rized modification. This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of being damaged as a result of excessive corrosion; or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating conditions outside of OMEGA’s control. Components which wear are not warranted, including but not limited to contact points, fuses, and triacs.
OMEGA is pleased to offer suggestions on the use of its various products. However, OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by it will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive and the total liability of OMEGA with respect to this order, whether based on contract, warranty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event shall OMEGA be liable for consequential, incidental or special damages.
CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical applications or used on humans. Should any Product(s) be used in or with any nuclear installation or activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility as set forth in our basic WARRANTY/ DISCLAIMER language, and additionally, purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product(s) in such a manner.
RETURN REQUESTS/ INQUIRIES
Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE RETURNING ANY PRODUCT(S) TO OMEGA , PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return package and on any correspondence.
The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in transit.
✓ ✓
✓ ✓ ✓ ✓ ✓
✓ ✓ ✓ ✓
✓ ✓
✓ ✓
User’s Guide
GENERAL DESCRIPTION
The CL220 is designed to be a simple to use, high accuracy thermocouple calibrator capable of either simulating or reading J, K, T, or E thermocouple types. A standard thermocouple mini-connector makes connections easy while providing direct contact with the internal cold junction compensation circuitry.
When used as a thermocouple simulator, the CL220 provides 2 sets of output control keys which allow the user to either “step” in 100° increments or scroll in smaller increments.
INSTALLATION
UNPACKING
Remove the Packing List and verify that all equipment has been received. If there are any questions about the shipment, please call Omega’s Custome Service Dept. at 1-800-826-6342.
When you receive the shipment, inspect the container and equipment for any signs of damage. Note any evidence of rough handling in transit. Immediately report any damage to the shipping agent.
NOTE
The carrier will not honor any claims unless all shipping material is saved for their examination. After examining and removing contents, save packing material and carton in the event reshipment is necessary.
SET-UP
Before beginning, become familiar with the keypad layout and the configuration of the input/output jacks. Remember, these jacks are used in multiple configurations so pay careful attention to how the test leads are connected for the specific application.
OPERATING PROCEDURE
1. Turn on power and select the desired thermocouple type by depressing the T/C SELECT key. Once the desired T/C is selected, it will remain in memory until a new T/C type is selected.
2. Select either Input or Output mode depending on whether you want to read a thermocouple or simulate a thermocouple signal.
3. Connect the appropriate thermocouple to the mini-connector on the top of the CL220.
4. If you are using the CL220 in the output mode use the STEP or SCROLL keys to set the output. The STEP key will step in 100° increments and the SCROLL key allows single degree increments which will increase in speed if the switch is depressed for several seconds.
OPERATING MODES
1. When operating in the thermocouple output mode, the CL220 has the ability to simulate up to 4 T/C types (J, K, T, E) into devices which measure thermocouples:
Note: If the CL220 is improperly connected to a low impedance load (either a short or near short) the display will flash “ERROR”.
FIGURE 1
SIMULATING A THERMOCOUPLE OUTPUT
2. When operating in the thermocouple Read Mode the CL220 can be used to read the temperature of a thermocouple probe.
In this mode, the CL220 will detect an open circuit should the thermocouple junction malfunction. In this case, the display will flash “OPEN”. It will also flash “OPEN” if no probe is connected in the Input Mode.
FIGURE 2
READING A THERMOCOUPLE PROBE
SPECIFICATIONS
Ranges J -100 to 1000°C
K -100 to 1200°C T -100 to 400°C E -100 to 950°C
Resolution 1°C or 1°F
Accuracy ±1°C above 0°C;
±1.5°C below 0°C
1
Operating Temp. 0 to 50°C
Storage Temp. -20 to 60°C
Temperature Coef. .01% F.S./°C
Power
2
9V alkaline battery (Yields approx. 25 hrs. of operation)
Case Size 1.43” x 3.15” x 5.7”
Weight 12 oz.
Notes:
1
Accuracy is at 23°C ±2°C and includes
CJC error.
2
A low battery indication is given at 5.5 volts.
MAINTENANCE
Generally, with normal usage, this calibrator should hold its rated specifications for at least 12 months. Beyond this, it should remain within 1.5X of its specification over its useful life, provided it is not abused or tampered with. If after the stated warranty period, the device falls out of calibration, it can be returned to Omega for re-calibration. Please call 1-800-826-6342 for pricing and return information.
}
All ranges can be read in °C or °F
Loading...