⻬ 2-Channel Input
⻬ Simultaneous Display
⻬ AC Line-Voltage
or DC Powered
⻬ Display and/or Control: µS, mS, PPM
or PPB (TDS), kΩ, MΩ, % Rejection,
Difference, Ratio, °C or °F
⻬ 3 Fully Scalable
4 to 20 mA Outputs
⻬ Up to 4 Programmable Relays
⻬ Time Delay Relay Function
⻬ Proportional Pulse
Control Capability
⻬ Meets USP Requirements
⻬ Programmable Temperature
Compensation
⻬ Output Simulation for Complete
System Testing
⻬ Simple Push-Button Operation
1
⻬
⁄4 DIN, NEMA 4X (IP65) Enclosure
with Self-Healing Window
Application
⻬ RO/DI System Control
⻬ Demineralizer Regeneration and
Rinse
⻬ Scrubber, Cooling Tower
and Boiler Protection
⻬ Chemical Concentration
⻬ Rinse Tank Water Quality
⻬ Desalinization
⻬ Leak Detection
⻬ Aquatic Animal
Life Support Systems
⻬ Aquaculture
⻬ Environmental Studies
CDCN-91, $1075, shown actual size.
The CDCN-91 Series dual channel
conductivity/resistivity controller is a twochannel input device equipped with three
scalable 4 to 20 mA outputs and four
programmable relays. A selector switch
activates two open collector outputs in
place of two of the relays for extraordinary
output versatility. Dual input and advanced
control capability, including percent
rejection, difference and ratio calculations,
together with the CDCE-91 Series
conductivity sensors listed below, form the
perfect measurement and control system
for water treatment applications and more.
Two versions are available: one accepts
AC line-voltage, the other low voltage DC
for power. The four-button keypad
arrangement with intuitive software design
is user-friendly, and the NEMA 4X (IP65)
integrity of the front panel can be extended
to the entire enclosure by using the
optional rear cover kit.
Specifications
General
Compatible Sensors: CDCE-90 Series
standard conductivity/resistivity sensors
Operating Range:
Conductivity: 0.055 to 400,000 µS/cm
Resistivity: 10 kΩ/cm to 18.26 MΩ/cm
(0.055 to 100 µS/cm)
TDS: 0.001 to 999999 ppm or ppb
(display limit)
Temperature: PT1000: -25 to 120°C
(-13 to 248°F)
Accuracy:
Conductivity/Resistivity:
±2% of reading
Temperature: ±0.5°C
Power Requirements:
100 to 240 Vac:
±10%, 50 to 60 Hz, 20 VA
11 to 24 Vdc: ±10% reg., 0.5A max
Display: Alphanumeric 2 x 16 LCD
Contrast: User selected, 5 levels
Update rate: 1.5 seconds
Current Outputs: (3 each) 4 to 20 mA,
isolated, fully adjustable and reversible
Max Loop Impedance: 150 Ω @ 12V,
450 Ω @ 18V, 750 Ω @ 24V
Update Rate: Approx. 100 mS
Accuracy: ±0.03 mA @ 25°C, 24 Vdc
Open Collector Outputs: (2 each)
Isolated, 50 mA sink or source, 30 Vdc
max pull-up voltage
Operational Settings: Hi, Lo, USP,
Pulse, Off
Hysteresis: User adjustable
Time Delay: 0 to 6400 seconds
Maximum Pulse Rate:
400 pulses/minute
Alarm Contacts: (up to 4 each)
SPDT Relays
Maximum Voltage Ratings:
5A @ 30 Vdc or 5A @ 250 Vac
Operational Settings: Hi, Lo, USP,
Pulse, Off
Hysteresis: User adjustable
Time Delay: 0 to 6400 seconds
Maximum Pulse Rate:
400 pulses/minute
E-29
Our Conductivity Instruments product line continues
to expand, visit omega.com for new details!
For Sales
& Service
U.S.A. and Canada
Page 2
omega.comomega.com
®
102
(4.0)
56
(2.2)
96 (3.8)
96
(3.8)
Panel Cutout
92 x 92
(+ 0.8, - 0)
3.6 x 3.6
(+0.031, -0)
Optional
Rear Cover
FP90-4X
Panel
gasket
Rear Cover
4-screws
RELAY 1
RELAY 2
RELAY 3
RELAY 4
N/CN/O COM
N/C
N/OCOM N/C
N/O
COM N/CN/O
COM
RELAY 3,4
OPEN
COLL 3,4
- OPEN COLL 4
+
OPEN COLL 4
-
OPEN COLL 3
+
OPEN COLL 3
-
LOOP 2
+
LOOP 2
-
LOOP 3
+
LOOP 3
-
LOOP 1
+
LOOP 1
SHLD
ISO GND
TEMP 1
SGNL 1
SHLD
ISO GND
TEMP 2
SGNL 2
POWER
OUTPUT OPTION
Æ
L
N
-
+
cable
Liquid Tig ht
Connector
(ordered
separately)
quick-clip
gasket on
front side
of panel
panel
terminals
mounting
bracket
RELAY 1
RELAY 2
RELAY 3
RELAY 4
N/CN/O COM N/C
N/OCOM N/C
N/O
COM N/C N/O
COM
RELAY 3,4
OPEN
COLL 3,4
- OPEN COLL 4
+
OPEN COLL 4
-
OPEN COLL 3
+
OPEN COLL 3
-
LOOP 2
+
LOOP 2
-
LOOP 3
+
LOOP 3
-
LOOP 1
+
LOOP 1
SHLD
ISO GND
TEMP 1
SGNL 1
SHLD
ISO GND
TEMP 2
SGNL 2
POWER
OUTPUT OPTION
Æ
L
N
-
+
RELAY 1
RELAY 2
RELAY 3 RELAY 4
N/C N/O COM N/C N/O COM N/C N/O COM N/C N/O COM
RELAY 3,4
OPEN
COLL 3,4
- OPEN COLL 4
+ OPEN COLL 4
- OPEN COLL 3
+ OPEN COLL 3
- LOOP 2
+ LOOP 2
- LOOP 3
+ LOOP 3
- LOOP 1
+ LOOP 1
SHLD
ISO GND
TEMP 1
SGNL 1
SHLD
ISO GND
TEMP 2
SGNL 2
POWER
OUTPUT OPTION
Æ
L
N
-
+
11 - 24V
0.5 A
L
N
-
+
3-8860.610A 4/00
100 - 240V
50-60Hz, 20VA
~
Enclosure
Rating: NEMA 4X (IP65) front and
back with optional NEMA 4X (IP65)
rear cover kit
Materials:
Case: PBT
Window: Polyurethane-coated
polycarbonate
Keypad: Sealed 4-key silicone rubber
Weight:
CDCN-91AC: Approx. 581 g (20.5 oz)
CDCN-91: Approx. 544 g (19.2 oz)
INSTALLATION
⻬ Front Panel provides
NEMA 4X (IP65) protection
⻬ Standard
⻬ 102 mm (4") mounting depth
⻬ Optional NEMA 4X (IP65) rear cover
kit with knockout ports
for cable access
⻬ 158 mm (6.3") mounting depth with
optional rear cover installed
1
⁄4 DIN panel cutout
Dimensions: mm (in)
Panel mounting
bracket and panel
gasket are included.
Optional heavy-duty
wall mount bracket
CDCN-91-WMB, $52.
AVAILABLE FOR FAST DELIVERY!
To Order (Specify Model Number)
Model No.PriceDescription
CDCN-91$1075Conductivity/resistivity controller DC power
CDCN-91AC1085Conductivity/resistivity controller AC/DC power
Calibrators, Connectors, General Test and Measurement
Instruments, Glass Bulb Thermometers, Handheld Instruments
for Temperature Measurement, Ice Point References,
Indicating Labels, Crayons, Cements and Lacquers, Infrared
Temperature Measurement Instruments, Recorders Relative
Humidity Measurement Instruments, RTD Probes, Elements
and Assemblies, Temperature & Process Meters, Timers and
Counters, Temperature and Process Controllers and Power
Switching Devices, Thermistor Elements, Probes and
Assemblies,Thermocouples Thermowells and Head and Well
Assemblies, Transmitters, Wire
Flow and Level
Air Velocity Indicators, Doppler Flowmeters, Level
Measurement, Magnetic Flowmeters, Mass Flowmeters,
Pitot Tubes, Pumps, Rotameters, Turbine and Paddle Wheel
Flowmeters, Ultrasonic Flowmeters, Valves, Variable Area
Flowmeters, Vortex Shedding Flowmeters
pH and Conductivity
Conductivity Instrumentation, Dissolved Oxygen
Instrumentation, Environmental Instrumentation, pH
Electrodes and Instruments, Water and Soil Analysis
Instrumentation
Data Acquisition
Auto-Dialers and Alarm Monitoring Systems,
Communication Products and Converters, Data
Acquisition and Analysis Software, Data Loggers
Plug-in Cards, Signal Conditioners, USB, RS232, RS485
and Parallel Port Data Acquisition Systems, Wireless
Transmitters and Receivers
Band Heaters, Cartridge Heaters, Circulation Heaters,
Comfort Heaters, Controllers, Meters and Switching
Devices, Flexible Heaters, General Test and Measurement
Instruments, Heater Hook-up Wire, Heating Cable
Systems, Immersion Heaters, Process Air and Duct,
Heaters, Radiant Heaters, Strip Heaters, Tubular Heaters
click here to go to the omega.com home page
Loading...
+ hidden pages
You need points to download manuals.