Conductivity or Resistivity Controller
CDCN441
925
Analyzer/Transmitter/Controller Self-Guided Menu Auto-Range Scales Automatic Calibration and Check Recognizes Standard and Cell Automatic Temperature Compensation On-Off/PWM Control Programmable Transmitter Output RS485 Output
The CDCN441 conductance/resistance analyzer­controller is designed for online monitoring of process solutions and water applications. Applications include: waste water treatment, power plants, thermo electric plants, pharmaceutical, photographic industries and soft drinks industries. The menus are self guiding with simple three button programming. Available control outputs include ON­OFF or pulse width modulation. The transmitter output is also programmable from the keypad eliminating the need for potentiometer or dip-switch settings. The calibration function automatically recognizes the cell used and the buffer solution resulting in a simple and straight forward system calibration.
Equipment is built with solid state technology, electronic contacts and not electrical contacts, avoiding mechanical movement and off course no sparks.
Specifications
General
Construction/Materials:
Case: Aluminum (SAE323)
Faceplate: ABS Anti-Corrosion Treatment: Finished with electrostatic epoxy paint Case Rating: NEMA 4 (IP68) Power Consumption: 3.5 VA Power: 90/240 Vac; 50/60Hz LCD Readout: 2 lines x 16 characters Reading Modes: Continuous, average or hold Assembly in 51 mm (2") Tube or Flat Surface or Panel:
144 x 144 x 100 mm DIN (5.7 x 5.7 x 4")
Weight: 1.3 kg (2.8 lb) RS485 Output: MODBUS
®
and proprietary
communication protocol
Analyzer
Conductivity Range: 1µS/cm to 2S/cm Resistivity Range: 10 MΩ/cm to infinity Resolution: 0.1 or 0.01 Automatic or Manual Temperature Compensation: 0 to 100°C
(32 to 212°F)
Temperature Compensation: NTC-R typical 5 Ω at 25°C (77°F) Operating Temperature: 5 to 40°C (41 to 104°F) Cell Constants Offered: K = 0.01/0.1/5/5/10
Transmitter
Analog Output: 4 to 20 mA (2), this output
can be programmed for transmission
Impedance: 600 Ω Optical Galvanic Isolation: 2000 Vac Controller Outputs: 2 N.O. (1A/240 Vac) on/off alarm or PWM;
4 to 20 mA for PID control or retransmission
Cells
CDE-440-001:
Range: 0.01 µS to 2mS, K = 0.01,
0 to 100°C (32 to 212°F), 10 kg/cm
2
Insertion Length: 54 mm (2.1") Thread: 316 SS, 3⁄4 NPT
CDE-440-01:
Range: 0.1 µS to 20 mS, K = 0.1,
0 to 130°C (32 to 266°F), 10 kg/cm
2
Insertion Length: 42 mm (1.7") Thread: 316 SS, 3⁄4 NPT
CDE-440-1:
Range: 0.1 µS to 100 mS, K = 1,
0 to 130°C (32 to 266°F), 10 kg/cm
2
,
Insertion Length: 60 mm (2.4") Thread: 316 SS, 3⁄4 NPT
CDE-440-5:
Range: 1 µS to 150 mS, K = 5,
0 to 130°C (32 to 266°F), 10 kg/cm
2
,
Insertion Length: 60 mm (2.4") Thread: 316 SS, 3⁄4 NPT (PVDF body)
CDE-440-01T:
Range: 0.1 µS to 20 mS, K = 0.1,
0 to 200°C (32 to 392°F), 10 kg/cm2,
Insertion Length: 90 mm (3.5") Thread: 316 SS, 3⁄4 NPT
CDCN441, $925, shown smaller than actual size.
E-34
Order Online
Over 100,000 Products Available!
omega.comomega.com
®
To download information and to order Conductivity Instrument products online, visit omega.com
Model No. Price Description
CDSA-10 $23 10 µS calibration solution 940 mL (1 qt) CDSA-45 10 45 µS calibration solution 940 mL (1 qt) CDSA-450 10 450 µS calibration solution 940 mL (1 qt) CDSA-1500 10 1500 µS calibration solution 940 mL (1 qt) CDSA-4500 10 4500 µS calibration solution 940 mL (1 qt) CDSA-45000 10 45000 µS calibration solution 940 mL (1 qt) ES-1512 140 Reference Book: Principles of Groundwater Engineering
Accessories
To Order
(Specify Model Number)
Model No. Price Description
CDCN441 $925 Conductivity/resistivity controller with relay and 4 to 20 mA outputs CDE-440-001 440 Conductivity sensor, K = 0.01, 0.01 µS to 2 mS, 0 to 100°C (32 to 212°F) CDE-440-01 440 Conductivity sensor, K = 0.1, 0.1 µS to 20 mS, 0 to 130°C (32 to 266°F) CDE-440-1 500 Conductivity sensor, K = 1, 0.1 µS to 100 mS, 0 to 130°C (32 to 266°F) CDE-440-5 480 Conductivity sensor, K = 5, 0.1 µS to 150 mS, 0 to 130°C (32 to 266°F) CDE-440-01T 625 Conductivity sensor, K = 0.1 heavy duty, 0.1 µS to 20 mS, 0 to 200°C (32 to 392°F)
Comes complete with 316 SS hardware for 51 mm (2") tube installation and wall mount brackets and operator’s manual. Sensors sold separately.
Ordering Examples: CDCN441, conductivity/resistivity controller, $925. CDE-440-5, sensor K = 5 (PVDF material), $480.
MOST POPULAR MODELS HIGHLIGHTED!
CDE-440-001, $440, shown smaller than actual size.
CDE-440-01T, $625, shown smaller than actual size.
CDE-440-5, $480, shown smaller than actual size.
CDSA calibration solutions,
see accessories chart below.
Loading...
+ 1 hidden pages