Conductivity and pH Water Treatment Controllers
CDCN Series
Starts at
1225
Common Features
Digital Conductivity Display and ControlTemperature DisplayThree Chemical Feed Programs
(Conductivity, pH and Additive)
Langelier Saturation Index
for Water Balance
Chemical Level AlarmIntegral Data Logging
for up to 999 Points
Time-Based Chemical Level AlarmNEMA 4X Wall Mount EnclosureRemote Computer Operation
with Windows Software Model CDCN11 One Line LCD Readout with
5-Button Keypad Relays for 3 Additive Programs,
Bleed and Alarm Conductivity/Temperature,
Water Meter and Flow Switch Inputs Watermeter Totalizer Function Model CDCN12 4-Line LCD Readout with
16-Key Numeric Keypad
Probe Failure Indication and Alarm4 Relays for Additives and/or AlarmQuick Release Enclosure Design
for Fast Access and Wiring Options Include
pH ControlSafety Flow SwitchRS485 Communications
CDCN11, $1225, shown smaller than actual size.
The CDCN10 Series is specifically designed to measure conductivity/dissolved solids and pH in cooling towers, boilers, industrial process water, food processing, drinking water and wastewater treatment applications. The CDCN10 Series conductivity/pH controllers are highly accurate and easy to install and operate. Engineering units can be displayed in either US or metric values using the pushbutton keypad and the simple scroll-through menus. Both units control conductivity, with the ability to control 3 additive feed programs. You can get a readout of the probe temperature. pH measurement and control is optional on both units, as is a safety flow switch contact, and RS485 communications.
The CDCN12 has additional features over the standard CDCN11, including dynamic probe failure testing for pH/ORP sensors, allowing the controller to detect a probe failure quickly after it occurs, so the user can avoid dangerous out-of-range conditions. For convenience, the CDCN12 features a large 4-line LCD readout and 16-button keypad.
E-39
Our Conductivity Instruments product line continues to expand, visit omega.com for new details!
CDCN12-PH, $2300 with PHE10 pH electrode, $195, shown smaller than actual size.
For Sales & Service
U.S.A. and Canada
Page 2
omega.comomega.com
®
Specifications
Measurement Range: Conductivity: 0 to 20,000 µS/cm or ppm; conversion factor for TDS pH: 0 to 14 pH; setpoint for acid or base feed Accuracy:
Conductivity: ±1% rdg pH: ±0.1 pH
Resolution:
Conductivity: 1µS
pH: 0.01 pH Temperature Range: -18 to 60°C (0 to140°F) Watermeter Input: For totalizer function, CDCN11 only Sensor Calibration: 1, 2 or 3 points Control Modes: Off, manual, auto, timer, bleed and feed,
bleed-then-feed, daily schedule Langelier Index: Water balance display calculated from pH, temp, total alkalinity and calcium hardness Alarms: High/low, out-of-range, overfeed and total run time; visual, audible and external (5 A) alarms Data Logging: On-board memory for 999 tests; CDCN12 has RS232 communication port for local download and printing
To Order
(Specify Model Number)
Model No. Price Input Communications Keypad/Display
CDCN11 $1225 Conductivity 5-button/one line CDCN11-PH 1875 Conductivity/pH 5-button/one line CDCN11-485 1775 Conductivity RS485 5-button/one line CDCN11-PH-485 2425 Conductivity/pH RS485 5-button/one line CDCN12 1650 Conductivity RS232 16-button/four line CDCN12-PH 2300 Conductivity/pH RS232 16-button/four line CDCN12-485 2200 Conductivity RS232, RS485 16-button/four line CDCN12-PH-485 2850 Conductivity/pH RS232, RS485 16-button/four line
Networking: RS485 port for multiple connections (optional) Remote Operation: Software and graphical display for Windows Power: 115/230 Vac, 10 A Control Outputs: 5 A relays, SPST
CDCN11 Relays: 3 additive, one alarm, one bleed CDCN12 Relays: 2 additive, one additive/alarm (selectable),
one bleed
Probe Sensor Failure: CDCN12 only, for pH/ORP electrode Display:
CDCN11: One line LCD; 5-button keypad
CDCN12: Four line LCD; 16-button keypad Mechanical: NEMA 4X enclosure Dimensions:
CDCN11: 240 x 190 x 90 mm (9.5 x 7.5 x 3.5")
CDCN12: 285 x 234 x 155 mm (11.21 x 9.21 x 6.09") Shipping Weight:
CDCN11: 2.7 kg (6 lb)
CDCN12: 6.0 kg (13 lb)
MOST POPULAR MODELS HIGHLIGHTED!
®
Accessories (Recommended Buffer and Conductivity Solutions)
Model No. Price Description
CDE10 $205 Conductivity sensor CDE10HP 375 High pressure conductivity sensor PHE10 195 pH electrode PHE10HP 335 High pressure pH electrode FSW10S 170 Shuttle style flow switch FSW10B 170 Blade style flow switch PHA-4 5 4.00 pH buffer solution, 500 mL (1 pt) bottle PHA-7 5 7.00 pH buffer solution, 500 mL (1 pt) bottle PHA-10 5 10.00 pH buffer solution, 500 mL (1 pt) bottle CDSA-45 10 45 µmho/cm conductivity solution, 946 mL (1 qt) CDSA-1413 23 1413 µmho/cm conductivity solution, 946 mL (1 qt) CDSA-1500 10 1500 µmho/cm conductivity solution, 946 mL (1 qt)
Comes complete with operator’s manual and 3V lithium battery. Probes sold separately. Note: When ordering the conductivty or pH controller, it is recommended to purchase pH buffer solution, such as PHA-7, pH buffer 7 and
conductivity standard solution, such as CDSA-1413, 1413 µS/cm, $23. Ordering Examples: CDCN11, conductivity controller, CDE10, conductivity sensor, CDSA-1413, conductivity standard solution, 1413 µS/cm,
$1225 + 205 + 23 = $1453.
CDCN12-PH, conductivity/pH controller with 4 to 20 output, PHE10, pH electrode, PHA-7, pH 7 buffer solution, $2300 + 195 + 5 = $2500.
Order Online
To download information and to order Conductivity
Over 100,000 Products Available!
Instrument products online, visit omega.com
E-40
Page 3
One Omega Drive | Stamford, CT 06907 | 1-888-TC-OMEGA (1-888-826-6342) | info@omega.com
EPG05
www.omega.com
UNITED KINGDOM
www. omega.co.uk
Manchester, England
0800-488-488
UNITED STATES
www.omega.com
1-800-TC-OMEGA
Stamford, CT.
CANADA
www.omega.ca
Laval(Quebec)
1-800-TC-OMEGA
GERMANY
www.omega.de
Deckenpfronn, Germany
0800-8266342
Karviná, Czech Republic
FRANCE
www.omega.fr
Guyancourt, France
088-466-342
CZECH REPUBLIC
www.omegaeng.cz
596-311-899
BENELUX
www.omega.nl
Amstelveen, NL 0800-099-33-44
More than 100,000 Products Available!
Temperature
Calibrators, Connectors, General Test and Measurement Instruments, Glass Bulb Thermometers, Handheld Instruments for Temperature Measurement, Ice Point References, Indicating Labels, Crayons, Cements and Lacquers, Infrared Temperature Measurement Instruments, Recorders Relative Humidity Measurement Instruments, RTD Probes, Elements and Assemblies, Temperature & Process Meters, Timers and Counters, Temperature and Process Controllers and Power Switching Devices, Thermistor Elements, Probes and Assemblies,Thermocouples Thermowells and Head and Well Assemblies, Transmitters, Wire
Flow and Level
Air Velocity Indicators, Doppler Flowmeters, Level Measurement, Magnetic Flowmeters, Mass Flowmeters, Pitot Tubes, Pumps, Rotameters, Turbine and Paddle Wheel Flowmeters, Ultrasonic Flowmeters, Valves, Variable Area Flowmeters, Vortex Shedding Flowmeters
pH and Conductivity
Conductivity Instrumentation, Dissolved Oxygen Instrumentation, Environmental Instrumentation, pH Electrodes and Instruments, Water and Soil Analysis Instrumentation
Data Acquisition
Auto-Dialers and Alarm Monitoring Systems, Communication Products and Converters, Data Acquisition and Analysis Software, Data Loggers Plug-in Cards, Signal Conditioners, USB, RS232, RS485 and Parallel Port Data Acquisition Systems, Wireless Transmitters and Receivers
Pressure, Strain and Force
Displacement Transducers, Dynamic Measurement Force Sensors, Instrumentation for Pressure and Strain Measurements, Load Cells, Pressure Gauges, Pressure Reference Section, Pressure Switches, Pressure Transducers, Proximity Transducers, Regulators, Strain Gages, Torque Transducers, Valves
Heaters
Band Heaters, Cartridge Heaters, Circulation Heaters, Comfort Heaters, Controllers, Meters and Switching Devices, Flexible Heaters, General Test and Measurement Instruments, Heater Hook-up Wire, Heating Cable Systems, Immersion Heaters, Process Air and Duct, Heaters, Radiant Heaters, Strip Heaters, Tubular Heaters
click here to go to the omega.com home page
Loading...