⻬ Digital Conductivity Display and Control
⻬ Temperature Display
⻬ Three Chemical Feed Programs
(Conductivity, pH and Additive)
⻬ Langelier Saturation Index
for Water Balance
⻬ Chemical Level Alarm
⻬ Integral Data Logging
for up to 999 Points
⻬ Time-Based Chemical Level Alarm
⻬ NEMA 4X Wall Mount Enclosure
⻬ Remote Computer Operation
with Windows Software
Model CDCN11
⻬ One Line LCD Readout with
5-Button Keypad
⻬ Relays for 3 Additive Programs,
Bleed and Alarm
⻬ Conductivity/Temperature,
Water Meter and Flow Switch Inputs
⻬ Watermeter Totalizer Function
Model CDCN12
⻬ 4-Line LCD Readout with
16-Key Numeric Keypad
⻬ Probe Failure Indication and Alarm
⻬ 4 Relays for Additives and/or Alarm
⻬ Quick Release Enclosure Design
for Fast Access and Wiring
Options Include
⻬ pH Control
⻬ Safety Flow Switch
⻬ RS485 Communications
CDCN11, $1225,
shown smaller
than actual size.
The CDCN10 Series is specifically designed to measure
conductivity/dissolved solids and pH in cooling towers, boilers,
industrial process water, food processing, drinking water and
wastewater treatment applications. The CDCN10 Series
conductivity/pH controllers are highly accurate and easy to install
and operate. Engineering units can be displayed in either US or
metric values using the pushbutton keypad and the simple
scroll-through menus. Both units control conductivity, with the
ability to control 3 additive feed programs. You can get a readout
of the probe temperature. pH measurement and control is optional
on both units, as is a safety flow switch contact, and RS485
communications.
The CDCN12 has additional features over the standard CDCN11,
including dynamic probe failure testing for pH/ORP sensors,
allowing the controller to detect a probe failure quickly after it
occurs, so the user can avoid dangerous out-of-range conditions.
For convenience, the CDCN12 features a large 4-line LCD readout
and 16-button keypad.
E-39
Our Conductivity Instruments product line continues
to expand, visit omega.com for new details!
CDCN12-PH, $2300 with PHE10
pH electrode, $195, shown
smaller than actual size.
For Sales
& Service
U.S.A. and Canada
Page 2
omega.comomega.com
®
Specifications
Measurement Range:
Conductivity: 0 to 20,000 µS/cm or ppm; conversion factor for TDS
pH: 0 to 14 pH; setpoint for acid or base feed
Accuracy:
Conductivity: ±1% rdg
pH: ±0.1 pH
Resolution:
Conductivity: 1µS
pH: 0.01 pH
Temperature Range: -18 to 60°C (0 to140°F)
Watermeter Input: For totalizer function, CDCN11 only
Sensor Calibration: 1, 2 or 3 points
Control Modes: Off, manual, auto, timer, bleed and feed,
bleed-then-feed, daily schedule
Langelier Index: Water balance display calculated from pH,
temp, total alkalinity and calcium hardness
Alarms: High/low, out-of-range, overfeed and total run time;
visual, audible and external (5 A) alarms
Data Logging: On-board memory for 999 tests; CDCN12 has
RS232 communication port for local download and printing
To Order
(Specify Model Number)
Model No.PriceInputCommunicationsKeypad/Display
CDCN11$1225Conductivity—5-button/one line
CDCN11-PH1875Conductivity/pH—5-button/one line
CDCN11-4851775ConductivityRS4855-button/one line
CDCN11-PH-4852425Conductivity/pHRS4855-button/one line
CDCN121650ConductivityRS23216-button/four line
CDCN12-PH2300Conductivity/pHRS23216-button/four line
CDCN12-4852200ConductivityRS232, RS48516-button/four line
CDCN12-PH-4852850Conductivity/pHRS232, RS48516-button/four line
Networking: RS485 port for multiple connections (optional)
Remote Operation: Software and graphical display for Windows
Power: 115/230 Vac, 10 A
Control Outputs: 5 A relays, SPST
CDCN11 Relays: 3 additive, one alarm, one bleed
CDCN12 Relays: 2 additive, one additive/alarm (selectable),
one bleed
Probe Sensor Failure: CDCN12 only, for pH/ORP electrode
Display:
CDCN11: One line LCD; 5-button keypad
CDCN12: Four line LCD; 16-button keypad
Mechanical: NEMA 4X enclosure
Dimensions:
CDCN11: 240 x 190 x 90 mm (9.5 x 7.5 x 3.5")
CDCN12: 285 x 234 x 155 mm (11.21 x 9.21 x 6.09")
Shipping Weight:
CDCN11: 2.7 kg (6 lb)
CDCN12: 6.0 kg (13 lb)
MOST POPULAR MODELS HIGHLIGHTED!
®
Accessories (Recommended Buffer and Conductivity Solutions)
Comes complete with operator’s manual and 3V lithium battery. Probes sold separately.
Note: When ordering the conductivty or pH controller, it is recommended to purchase pH buffer solution, such as PHA-7, pH buffer 7 and
conductivity standard solution, such as CDSA-1413, 1413 µS/cm, $23.Ordering Examples: CDCN11, conductivity controller, CDE10, conductivity sensor, CDSA-1413, conductivity standard solution, 1413 µS/cm,
Calibrators, Connectors, General Test and Measurement
Instruments, Glass Bulb Thermometers, Handheld Instruments
for Temperature Measurement, Ice Point References,
Indicating Labels, Crayons, Cements and Lacquers, Infrared
Temperature Measurement Instruments, Recorders Relative
Humidity Measurement Instruments, RTD Probes, Elements
and Assemblies, Temperature & Process Meters, Timers and
Counters, Temperature and Process Controllers and Power
Switching Devices, Thermistor Elements, Probes and
Assemblies,Thermocouples Thermowells and Head and Well
Assemblies, Transmitters, Wire
Flow and Level
Air Velocity Indicators, Doppler Flowmeters, Level
Measurement, Magnetic Flowmeters, Mass Flowmeters,
Pitot Tubes, Pumps, Rotameters, Turbine and Paddle Wheel
Flowmeters, Ultrasonic Flowmeters, Valves, Variable Area
Flowmeters, Vortex Shedding Flowmeters
pH and Conductivity
Conductivity Instrumentation, Dissolved Oxygen
Instrumentation, Environmental Instrumentation, pH
Electrodes and Instruments, Water and Soil Analysis
Instrumentation
Data Acquisition
Auto-Dialers and Alarm Monitoring Systems,
Communication Products and Converters, Data
Acquisition and Analysis Software, Data Loggers
Plug-in Cards, Signal Conditioners, USB, RS232, RS485
and Parallel Port Data Acquisition Systems, Wireless
Transmitters and Receivers
Band Heaters, Cartridge Heaters, Circulation Heaters,
Comfort Heaters, Controllers, Meters and Switching
Devices, Flexible Heaters, General Test and Measurement
Instruments, Heater Hook-up Wire, Heating Cable
Systems, Immersion Heaters, Process Air and Duct,
Heaters, Radiant Heaters, Strip Heaters, Tubular Heaters
click here to go to the omega.com home page
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.