Conductivity Transmitters
CDTX-90 Series
Starts at
$
620
Electronics
Only
⻬ Display in µS, mS, kΩ, MΩ,
ppm (TDS)
⻬ Simulate Function
⻬ Programmable Temperature
Compensation
⻬ Relay Options
⻬ Dual Output Option Allows
Temperature and Process Signal
Transmission
⻬ 2 x 16 Character Dot Matrix LCD
⻬ Chemical Resistant Enclosure and
Self-Healing Window
⻬ Large Pushbuttons
⻬ Clearly Marked Terminal Labels
Applications
⻬ RO/DI System Control
⻬ Rinse Tank Control
⻬ Cooling Tower, Scrubber
or Blowdown Control
⻬ Environmental Study (TDS)
⻬ Desalination Monitor
⻬ Water Quality Monitoring
⻬ Leak Detection
⻬ Chemical Concentration
The CDTX-90 Series Conductivity/
Resistivity Transmitter is designed for
broad application and ease of setup and
use. The unit can be used for
conductance, resistance, or TDS signal
transmission and display. Mounting can be
accomplished in several options best
tailored to your application requirements.
Full microprocessor based electronics
allow wide operating range, and long term
signal stability due to the elimination or
potentiometers, jumpers and dip switches.
Specifications
General
Compatible Electrodes:
OMEGA®CDCE-90-X Series Conductivity/
Resistivity Electrodes (see page E-37)
Accuracy: ±2% of reading
Shown larger than actual size.
Enclosure:
Rating: NEMA 4X (IP65) front
Case: PBT
Window: Polyurethane
coated polycarbonate
Keypad: Sealed 4-Key
Silicone Rubber
Weight: Approx. 325 g (12 oz)
Display:
Alphanumeric: 2 x 16 LCD
Contrast: User selected, 5 levels
Environmental
Operating Temperature:
-10 to 70°C (14 to 158°F)
Storage Temperature:
-15 to 80°C (5 to 176°F)
Relative Humidity:
0 to 95% non-condensing
Electrical
Sensor Input Range:
Conductance: 0.055 to 400,000 µS
Resistivity: 10 KΩ to 18.2MΩ
TDS: 0.023 to 200,000 ppm
Temperature:
PT1000, -25 to 120°C (-13 to 248°F)
Current Output: 4 to 20 mA, isolated, fully
adjustable and reversible
Power: 12 to 24 Vdc ±5% regulated
Max Loop Impedance:
50Ω max @ 12 V,
325Ω max @ 18 V,
600Ω max @ 24 V
Update Rate: 0.5 seconds
Accuracy: ±0.03 mA @ 25°C, 24 V
Relay Output:
Mechanical SPDT Contacts:
Hi, Lo, Pulse, Off
Maximum Voltage Rating:
5 A @ 30 Vdc, or 5 A
@ 250 Vac resistive load
Hysteresis: User Adjustable
Max 400 pulses/min
Open Collector Output:
Hi, Lo, Pulse, Off.
Open collector, optically isolated,
50 mA max, sink, 30 Vdc max.
pull-up voltage. Max 400 pulses/min
E-35
For Sales
& Service
U.S.A. and Canada
Installation
The transmitter is available in a panel mount or a field version. Select the universal mount kit FP90UM to mount the transmitter on a
surface near the sensor.
1. Panel Mount
FP90UM
CDTX-90-XP
All Panel mount transmitters CDTX-90-XP include a mounting
bracket and gasket for a NEMA 4X (IP65) watertight panel
installation. Panel mount transmitters fit into a standard 1⁄4 DIN panel
cutout.
2. Universal Mount
Kit
CDTX-90-X
The Universal Mount Kit FP90UM can be ordered separately
and includes a conduit base, locking ring, and universal
adapter for mounting the transmitter on a pipe, wall, or other
stationary surface.