Omega Products BAT-24-12 User Manual

Thermocouple Assemblies
NB1-2 rugged cast iron protection head and terminal block are included with the probe.
1
2 x 3⁄4 NPT fitting optional.
High-purity alumina protection tube.
Type R, S, or B platinum thermocouple enclosed in a high-purity alumina protection tube. Standard construction includes a cast iron NB1-2 connection head and 1⁄2 NPT fitting. For use at temperatures up to 1650°C (3000°F). Elements are insulated by a double-bore, high­purity, hard-fired alumina insulator.
High-Temperature
Platinum Thermocouples and Ceramic Protection Tubes
U Up to 1650°C (3000°F) Rating U Oxidizing or Reducing
Atmospheres
U Connection Head with
Terminal Block
U Custom Probe Lengths
Available
Insulators are 25 mm (1") long.
Length
Hard-fired
ceramic
insulators.
head, insulated element
and protection tube.
12 x 12 mm
1
(
2 x 1⁄2")
standard
RAT-30 -12
includes
Complete Assemblies
To Order Visit omega.com/rat_sat_bat for Pricing and Details
AWG Protection Insulator Model Thermocouple Wire Tube OD OD Number Calibration Size mm (inch) mm (inch)
RAT-30-12 Pt vs Pt 13% Rh 30 6.0 (
RAT-24-12 Pt vs Pt 13% Rh 24 6.0 (
RAT-20-12 Pt vs Pt 13%Rh 20 9.5 (
SAT-30-12 Pt vs Pt 10% Rh 30 6.0 (
SAT-24-12 Pt vs Pt 10% Rh 24 6.0 (
SAT-20-12 Pt vs Pt 10% Rh 20 9.5 (
BAT-30-12 Pt 6% Rh vs Pt 30% Rh 30 6.0 (
BAT-24-12 Pt 6% Rh vs Pt 30% Rh 24 6.0 (
BAT-20-12 Pt 6% Rh vs Pt 30% Rh 20 9.5 (
Note: Alumina tube shipped separately to avoid breakage. Shipped unassembled. Ordering Example: RAT-30-12, 30 AWG Type R thermocouple in a 300 mm (12") high-purity aluminum
protection tube and a cast iron head.
Replacement Elements for Assemblies Shown Above
Type AWG Insulator Type S Type R Type B of Wire 99.7% + PT- PT- PT/6%Rh­ Element Size Al2O3 PT/10%Rh PT/ 13%Rh PT/ 30%Rh
Bare wires 20 N/A Bare-20-S-12 Bare-20-R-12 Bare-20-B-12 (No 24 N/A Bare-24-S-12 Bare-24-R-12 Bare-24-B-12
Insulators) 30 N/A Bare-30-S-12 Bare-30-R-12 Bare-30-B-12
Double-Hole 20 XDH-20 XDH-20-S-12 XDH-20-R-12 XDH-20-B-12 Round 24 XDH-24 XDH-24-S-12 XDH-24-R-12 XDH-24-B-12 Insulators 30 XDH-30 XDH-30-S-12 XDH-30-R-12 XDH-30-B-12
Replacement elements include leads of sufficient length to reach terminals in head.
*
Note: Published price is based on market value at time of printing and is subject to change
(more or less) due to precious-metal market fluctuations.
A-125
1
4) 3.0 (1⁄8)
1
4) 3.0 (1⁄8)
3
8) 4.5 (3⁄16)
1
4) 3.0 (1⁄8)
1
4) 3.0 (1⁄8)
3
8) 4.5 (3⁄16)
1
4) 3.0 (1⁄8)
1
4) 3.0 (1⁄8)
3
8) 4.5 (3⁄16)
Wire Size Conversion
AWG Actual Diameter 6 4.1 mm (0.162")
8 3.2 mm (0.128") 10 2.5 mm (0.102") 12 2.0 mm (0.081") 14 1.6 mm (0.064") 16 1.2 mm (0.051") 18 1.0 mm (0.040") 20 0.8 mm (0.032") 22 0.6 mm (0.0253") 24 0.5 mm (0.0201") 26 0.41 mm (0.0159") 30 0.25 mm (0.0100")
Replacement protection tubes available; see PTRA Series. For 300 mm (12") probe length: add 48 mm (17⁄8") to length of tube to accommodate fitting. PTRA-31614-137/8-1 [for 6 mm (1/4") OD] PTRA-1438-137/8-1 [for 9.5 mm (3/8") OD]
Temperature and Pressure
P-OPNE-14 Fig. 1
Test Plugs
GASS18
Self-Sealing Insert
probe, shown
actual size.
A
GASS18
U 3 mm (1⁄8") Diameter Probe U Up to 1000 psig Between
-30 and 60°C (-20 and 140°F)
U Up to 135°C (275°F) U Two Self-Closing Valves U Heavy-Duty Design
OMEGA® self-sealing plugs will allow you to take pressure and temperature readings quickly and eliminate the need for leaving costly gages or temperature indicators on the line. The OMEGA® plug is permanently installed in the line at recommended test points. The cap protects the valve and provides an additional positive seal. After the cap has been removed, either a test thermometer or a gage adaptor with the proper pressure gage attached can be inserted through the two self­closing valves in the plug. Readings are taken, adjustments or tests can be made, and when the probes are withdrawn, the two valves close. The protective cap is then reinstalled.
Neoprene is resistant to deterioration from waxes, oils, greases, fats, petroleum products, and most refrigerants. It can be operated at a maximum temperature of 95°C (200°F) at 500 psig.
Nordel gives excellent service in hot or cold water and in some applications of low pressure steam. Nordel is resistant to detergents, phosphates, esters, ketones, alcohols, and glycols. It is not suitable for petroleum products. It can be operated at a maximum temperature of 135°C (275°F) at 500 psig.
Brass
Stainless Steel
Gage Adaptor
THE PRESSURE GAGE ADAPTOR HAS A 3 mm (1⁄8") DIAMETER PROBE OF 304 STAINLESS STEEL WITH UNION NUT. SIMPLY ATTACH YOUR GAGE/ TRANSDUCER AND INSERT THE PROBE THROUGH AN OMEGA® PLUG TO TAKE A READING.
Brass
Shown actual size.
OPN Series
Gage Adaptor
50.8
(2.0)
3.18
(0.13)
Protective Cover Included
Self Sealing Plug
3
1
2
3
4
5
Dimensions: mm (inch)
1. CAP & GASKET
2. TWO NEOPRENE OR NORDEL SELF-CLOSING VALVES
3. VALVE POCKET FOR ADDED PRESSURE PROTECTION
4. PROCESS THREAD
5. VALVE RETAINER
8-24
UNF
U Any Size Plug
Accepts up to a 3 mm (1⁄8 in) Dia. Probe
To Order Visit omega.com/rat_sat_bat for Pricing and Details
OMEGA Plug Model No. Fitting Valve Core Material
OPNE14 OPNO14 OPNE12 OPNO12 Gage Adaptor
Model No. Fitting Probe Diameter GASS18
Ordering Example: OPNE14, 1⁄4 NPT male fitting with Neoprene core and GASS18, probe/gage adaptor.
A-126
1
4 NPT male NEOPRENE
1
4 NPT male NORDEL®
1
2 NPT male NEOPRENE®
1
2 NPT male NORDEL®
1
4 NPT female 3.2 mm (1⁄8")
®
Loading...