Omega Products B8-CAXL-M30E-150 User Manual

Super OMEGACLAD® XL
High
Performance!
Thermocouple Probes
A Technological Advance in Temperature Measurement
KQXL-18U-12, shown smaller than actual size.
U
Thermocouple Technology from OMEGA for K and N Calibrations Only
U Super Stable Temperature Drift—
Less than 2.8°C in 25 weeks
U Better Performance at a Smaller
Size—0.8 mm Probe Withstands 815°C (1500°F) for 3 Years
U Probe Life Expectancy up to 10 Times
Greater than Competing Devices*
U Handles Temperatures Up to 1335°C
(2400°F)
Super OMEGACLAD® XL vs Inconel® 600,
0.8 mm (0.032") Dia., Type K Maintained at 815°C (1500°F)
830.0
suisleC seergeD ni erutarepmeT tseT
825.0
820.0
815.0
810.0
805.0
800.0
0510 15 20 25 30 35 40 45 50 55 60
* Tests conducted using ungrounded probes in an open-air, electric, muffle furnace versus a Type "S", NIST-traceable standard. Individual results may vary depending on customer application. Inconel
Super OMEGACLAD® XL Inconel® 600 Probe
Standard Limits of Error
Standard Limits of Error
Special Limits of Error
Special Limits of Error
Super OMEGACLAD® XL probe
Special Limits of Error
Special Limits of Error
Inconel® 600
Inconel® 600
probe failure
probe failure
Standard Limits of Error
Standard Limits of Error
Elasped Time - Weeks
®
is a registered trademark of Special Metals Corporation.
An Exclusive
OMEGA
Manufactured
OMEGA brings you the Super
Innovation
OMEGACLAD® XL Thermocouple Probe family, the exclusive innovation in thermocouple technology. Manufactured using state-of-the-art processes for mineral insulated (MI) thermocouple cable and finished thermocouple probe assemblies, these temperature sensors maximize performance, even at extremely small diameters. The devices resist carburization, oxidation, and chlorination in tough environments.
Small Size, Big Performance!
Typical 0.8 mm (0.032") Dia. Type K probes have a maximum tempera ture of 700°C (1260°F). Our Super OMEGACLAD
®
XL
0.8 mm (0.032") Dia. probe took on 815°C (1500°F) for 3 years and even reached 1000°C (1832°F) for 2 months!
Probes shown ~50%
smaller than actual size.
Approx. response time—ungrounded in water
**
0.250"
2.25 sec**
0.125"
0.55 sec**
0.062"
0.3 sec**
0.032"
~0.25 sec**
1204°C (2200°F) replace 17 of theirs in 52 days or just one of ours!
In life-cycle lab testing, the OMEGACLAD® XL sheathed, 0.125" Type K Probe operated continuously for 52 days at 1204°C (2200°F) while competitors’ 0.125" Inconel® 600 sheathed, Type K probes lasted 3 days.
† Results will vary on application and operating environment.
A-43
Long Life, Low Maintenance!
If your application operates at the punishing temperature of nearly 1204°C (2200°F), changing out failed thermocouples costs money in excessive maintenance, slows or cuts production, and can cause inconsistent product quality.
In head-to-head tests, Super OMEGACLAD XL Thermocouple probes consistently post the best performance results. Our innovative temperature sensors last upwards of 10 times or longer when compared to competitors’
®
Inconel
600 sheathed probes of equal or larger diameters. Let OMEGA’s leading edge products help engineer your next innovation!
®
OMEGA’s products making OMEGA’s products. OMEGA uses Super OMEGACLAD® XL thermocouple probes in its Class 10 clean rooms to monitor critical process temperatures and achieve consistent, high-quality products.
Low Drift, Reliable Temperatures!
Super OMEGACLAD® XL’s low-drift characteristic ensures reliability of temperature readings longer than any other brand or sheath material. Within 15 weeks, Brands A, B, and C exhibited more than
8.3°C drift. At 25 weeks, OMEGACLAD® XL’s drift was less than 2.8°C.*
Long-Term EMF Drift Test @ 1149°C (2100°F) K Calibration, 3.2 mm (1/8 in)
Diameter Probes Super OMEGACLAD
®
OMEGACLAD
15
10
5
0
4.6°C (8.4°F) @ 1149°C (2100°F)
Special Limits of Error
-5
Long-Term Drift°F
-10
-15
Tests conducted using ungrounded probes in an open-air,
*
electric, muffle furnace versus a Type “S”, NIST-traceable
XL
Elapsed Time - Weeks
standard. Individual results may vary depending on customer application. Inconel® is a registered trademark of Special Metals Corporation.
®
XL vs. Competitors
Brand BBrand A
OMEGACLAD® XL
INCONEL® 600
8.3
5.6
2.8
-2.8
-5.6
-8.3
2520151050
A
0
Long-Term Drift°C
Available as
Look for this logo to identify probes available in Super OMEGACLAD® XL sheathed thermocouple wire and probes
TJ36-CAXL-18U-12, shown smaller than actual size. Visit omega.com/tj36caxl_nnxl for OMEGA’s Super OMEGACLAD® XL probe offerings.
Take on High Temperatures!
Typical OMEGACLAD
5
0
-5
-10
-15
Deviation °F
-20
-25
-30
Measurements are taken at 1-hour intervals from 538 to 1338°C (1000 to 2440°F )
®
XL Type K Calibration 1.6 mm (1/16'') Diameter
Performance vs Competitors and Inconel
OMEGACLAD® XL
®
600
Inconel® 600Brand BBrand AOMEGACLAD® XL
133812041093982871760649538°C
24002200200018001600140012001000°F
5.5
2.8
-2.8
-5.5
-8.3
-11.1
-13.9
-16.6
°C10°F
0
Deviation °C
NB1-CAXL-14U-12, shown smaller than actual size.
In tests up to 1335°C (2400°F), Super OMEGACLAD® XL outperformed both the Inconel® 600 and other competing high-temperature models.
A-44