ARTWORK/PRODUCT ART/ HEATERS/H-AHPF TC
13
(0.50)
29
(1.13)
1
/
2
" NPT Female
Pipe Thread
Sensor Adaptor
Fitting-TC Series
1
/
2
" NPT
Male Pipe
Thread
14
(0.56)
1
/
4
" NPT Female
Pipe Thread
25
(1)
Air Heater
35
(1.38)
14
(0.56)
LOW FLOW AIR PROCESS AND
LIQUID CIRCULATION HEATERS
For In-Line Air, Gas and Liquid Heating
AHPF Series
U 316 Stainless Steel
Construction
U Air/Gas Flow up to 15 CFM
U Air/Gas Outlet
Temperatures up to
430°C (800°F)
U Pressures up to 100 psi*
U 50 Watts/Square Inch**
The AHPF Series heaters are used
to heat low flows of air, gas, water,
or aqueous solutions. Applications
include those where clean air is
necessary, as in laboratories and
environmental testing areas. The
stream of air is heated by passing
over an enclosed heated surface
rather than directly over resistance
elements. This method assures
that no foreign matter will enter the
stream of flow. The AHPF Series is
also used as a miniature circulation
heater for small volume of liquids as
in photographic developer solution,
chemicals, dyes, and inks. For
heating liquids, contact engineering.
The Thermocouple “T” fitting
AHPF‑NPT12 can be used with
the subminiature thermocouple
probes and with the SSLK series
stainless steel compression fittings
(see omega.com) and with stainless
steel compression fittings (Model
SSLK‑18‑14) to monitor or control
temperature at the outlet of the
AHPF series heaters.
SPECIFICATIONS
Cross Sectional Area:
0.152 square inches
Pressure Rating: Up to 100 psig
Wattage Tolerance: +5, ‑10% or better
at the voltage specified
Outside Diameter: 32 mm (1
Inlet: Male
Outlet:
122
3
⁄8" NPT
1
⁄2" NPT
To Order, Call or Shop Online at omega.com
AHPF-061
shown smaller
than actual size.
Length
8.0
For air/gas flow
up to 15 CFM.
AHPF-NPT12
Dimensions:
mm (inch)
6.0
4.0
2.0
Pressure Drop (psig)
0
0510 15
Air Flow (SCFM)
10"
HEATED
LENGTH
4" HEATED
LENGTH
CFM Maximum Watts/Linear
Inch of Heated Length
1 75
2 100
4 150
6 200
Model Number
AHPF-NPT12
8 200
10 250
15 275
To Order Visit omega.com/ahpf_heater for Pricing and Details
Model Heated Length Watts/ Max Length Weight
Number Volts Watts mm (inch) Inch* CFM mm (inch) kg (lb)
120 Vac Models
AHPF-061 120 400 102 (4) 91 15 152 (6) 0.45 (1.0)
AHPF-081 120 600 152 (6) 94 15 203 (8) 0.54 (1.18)
AHPF-101 120 1000 203 (8) 120 15 254 (10) 0.62 (1.37)
AHPF-121 120 1200 254 (10) 115 15 305 (12) 0.70 (1.55)
120/240 Volt Models**
AHPF-062 120 100 102 (4) 23 15 152 (6) 0.45 (1.0)
240 400 102 (4) 91 15
AHPF-082 120 150 152 (6) 23 15 203 (8) 0.54 (1.18)
240 600 152 (6) 94 15
AHPF-102 120 250 203 (8) 30 15 254 (10) 0.62 (1.37)
240 1000 203 (8) 120 15
AHPF-122 120 300 254 (10) 29 15 305 (12) 0.70 (1.55)
240 1200 254 (10) 115 15
* Indicates watts per inch of heated length. Use the table above to determine minimum
1
⁄4")
required flow rates. ** These air heaters can be operated on either 120 or 240V.
Specifications are shown for either 120 or 240V operation.
Ordering Example: AHPF-101, 120V, 1000 W low flow air process and liquid circulation heater.