SPECIFICATIONS
Sensitivity @ 100 Hz, ±10%: 100 mV/g Frequency Range:
±5% 5 Hz to 10 kHz ±10% 4 Hz to 12 kHz ±3 dB 2 Hz to 20 kHz
Turn-On Time: 0.5 s Amplitude Range: ±75 g peak Mounting Resonance: > 40 kHz Transverse Sensitivity: 5% Amplitude Linearity: <1% Noise (Typical):
Broadband:
2.5 Hz to 20 kHz 350 µg Spectral: 10 Hz 30 µg/µHz
100 Hz 8 µg/µHz 1000 Hz 3 µg/µHz
2-pin connector 5/8-24 thread MS3143
Dimensions: mm (inch)
22.2 (7/8) a/c flats
1/4-28 tapped mounting hole
Output Impedance: 100 Ω Grounding: Isolated Bias Voltage: 10 to 14 Vdc Power Requirement: 24 to 30 Vdc Current Regulating Diode:
1 to 6 mA cc Temperature Range: -40 to 121°C
(-40 to 250°F) Base Strain Sensitivity, Maximum:
0.001 g/microstrain Shock Limit: 5000 g peak
41
(1.615)
PHYSICAL Weight: 68 g (2.4 oz) Case Material: 304L SS Design: Piezoelectric—ring shear Sealing: Welded—hermetic Mounting: Mounting Torque: 2.8 N-m (25 in-lb) Mating Connector: Amphenol
97-3106A-10SL-4S Recommended Cabling: ACC-CB7-10
1
4-28 stud (not included)
To Order
MODEL NO. DESCRIPTION
ACC310 General purpose accelerometer with top exit connector
ACCESSORIES
MODEL NO. DESCRIPTION
ACC-CB7-10 3.05 m (10') MIL/BNC twisted-pair shielded cable ACC-CB7-10WP 3.05 m (10') waterproof twisted-pair shielded cable ACC-PS2 3-range battery-powered signal conditioner ACC-PS3 AC-powered signal conditioner ACC-CB6 17.8 cm (7") BNCM/pigtail coaxial cable
See omega.com for details on the above signal conditioners. Ordering Example: ACC310, accelerometer, ACC-CB7-10, cable, ACC-PS2, signal conditioner.
Visit omega.com/acc310 for Pricing and Details