GENERAL PURPOSE INDUSTRIAL-GRADE
ACCELEROMETERS
100 mV/g OUTPUT
ACC-101 shown
actual size.
ACC101
BOS-200 oscilloscope, visit
omega.com/bos_series.
U Ideal for Machine
Vibration Monitoring
U Low-Impedance Drives,
Cable Lengths to
304 m (1000')
U Fast Turn-On Time (1 s)
ACC-101 shown with ACC-PS1 power supply, and
BOS-200 oscilloscope, both sold separately.
The ACC101 accelerometer is
low cost yet extremely durable.
It is constructed of high-strength
aluminum; has a rugged strain
relief, a rugged 1⁄4-28 stud mounting,
and an epoxy seal; and uses the
kind of dependable components
usually found only in higher-priced
accelerometers.
SPECIFICATIONS
Excitation: 2 mA nominal @ 24 to
30 Vdc, constant current (18V supply
can be used but will limit amplitude
range)
Rated Output: 100 mV/g nominal
@ 100 Hz
Frequency Range: 3 Hz to 5 kHz
(up to ±10% rated output shift)
Amplitude Range: ±70 g peak with
ACC-PS1; ±80 g peak with ACC-PS2,
ACC-PS3
Amplitude Linearity: ±1% up to
65 g peak
Temperature Range: -18 to 82°C
(0 to 180°F)
Temperature Sensitivity Effect:
-54 to 38°C (-65 to 100°F) ≤5% FS
38 to 121°C (100 to 250°F) ≤8% FS
Thermal Shock: 1.2 g/°C
Transverse Sensitivity:
5% of axial maximum
Maximum g Without Damage:
5000 g peak
Maximum g Without Clipping:
±80 g peak
Mounted Resonance Frequency:
>18 kHz
Output Impedance: 50 Ω nominal
Bias Voltage: 10V nominal
25.4
(1.0)
Dimensions: mm (inch)
38.1
(1.5)
25 HEX BASE
1/4-28 X 0.2 NOMINAL
Base Strain: 0.002 g/microstrain max
Noise Floor (Wideband): 0.00025 g (rms)
Weight: 50 g (1.75 oz) nominal
(without cable)
To Order
MODEL NO. DESCRIPTION
ACC101 General purpose accelerometer
Visit omega.com/acc101 for Pricing and Details
(1.0)
Material: Aluminum; hard
anodized thermal insulating
boot included
Dimensions: 3.81 H x 2.54 cm
(1.50 x 1.0") hex base
Connector: 2.5 m (10') integral
coaxial cable with BNCM
Mounting:
Mounting Torque Maximum:
40 cm-kg (35 in-lb)
1
⁄4-28 removable stud
ACCESSORIES
MODEL NO. DESCRIPTION
MAGNET1 Magnetic mounting base (10 lb holding force)
POWER SUPPLIES/SIGNAL CONDITIONERS
ACC-PS1 Battery power supply (BNCF connections)
ACC-PS2
ACC-PS3 AC power supply (BNCF connections)
Interface cables used between power supply and instrumentation
ACC-CB4-15 4.6 m (15') coaxial cable (BNCM/BNCM)
ACC-CB5-2 0.6 m (2') coaxial cable (BNCM/banana plug)
ACC-CB6 178 mm (7") coaxial cable (BNCM/pigtail)
Comes complete with operator’s manual.
See omega.com for details on the above power supplies and cables.
Ordering Example: ACC101, accelerometer, ACC-PS1, power supply, and ACC-CB5-2,
coaxial cable.
25.4 Dia. x 31.8 mm H (1.00 x 1.25")
Rechargeable power supply/amplifier (BNCF connections)
DYNAMIC MEASUREMENT
K
K
K-6