Sputtered Gauge Pressure Transducer
with Amplifier/Regulator
Model 6SE01079
0 to 5 thru 0 to 5000 PSI
Isolated 0-5 VDC Output
To Order
(Specify Part Number)
Part
Number Instrument Range Units Accuracy
6SE01079-1 0-5 PSIG 0.25%
6SE01079-2 0-10 PSIG 0.25%
6SE01079-3 0-20 PSIG 0.25%
6SE01079-4 0-50 PSIG 0.25%
6SE01079-5 0-100 PSIG 0.25%
6SE01079-6 0-150 PSIG 0.25%
6SE01079-7 0-200 PSIG 0.25%
6SE01079-8 0-500 PSIG 0.25%
6SE01079-9 0-1000 PSIG 0.25%
6SE01079-10 0-1500 PSIG 0.25%
6SE01079-11 0-2000 PSIG 0.25%
6SE01079-12 0-5000 PSIG 0.25%
6SE01079-13 0-50 IN.HgG 0.25%
6SE01079-14 0-100 IN.HgG 0.25%
6SE01079-15 0-200 IN.HgG 0.25%
6SE01079-16 0-500 IN.HgG 0.25%
6SE01079-17 0-1000 IN.HgG 0.25%
6SE01079-18 0-20 PSIA 0.25%
6SE01079-19 0-50 IN.H2OG 0.25%
6SE01079-20 0-300 PSIG 0.25%
6SE01079-21 0-600 IN.HgG 0.25%
6SE01079-22 0-50 IN.HgA 0.25%
6SE01079-23 0-100 IN.HgA 0.25%
Ordering Example: 6SE01079-6, 0 to 150 psig sputtered strain gauge transducer,
0.1% accuracy with isolated 0 to 5 VDC output. Consult factory for price and delivery.
SPECIFICATIONS
Recommended Excitation: 28 ±4 VDC
Rated Output (RO): 5 VDC ±0.10%
(±10% Adjustable) Short Circuit Protected
Zero Balance (% RO): 0 VDC ±10% Adj. (Min.)
Temperature Effect on Zero Balance
(% RO): 0.0015/°F (0.0027%/°C)
Temperature Effect on Output
(% Reading): 0.0020/°F (0.0036/°C)
Compensated Temperature Range:
0 to 150°F (-18 to 66°C)
Safe Over Temperature Range:
-65 to 200°F (-54 to 93°C)
Safe Overpressure Range (%RO):
150% RO (Max.)
Ultimate Overpressure Range (%RO)
5 to 5000 psi: 300% RO (Max.)
(Diaphragm shall not rupture)
Combined Effects Non-Linearity, Hysteresis
and Repeatability: 0.15% (Typ.), 0.25% RO (Max.)
Vibration Limit (5-2000 Hz): 0.04% RO/G (Max.)
Thermal Zero Stability: 0.15% RO (Max)
Thermal Sensitivity Stability: 0.10% RO (Max.)
Total Error Band (RSS): Root Sum Square
(RSS) addition of errors due to non-linearity,
hysteresis, non-repeatability (BSL) zero balance
shift (±0.003% RO/°F Nominal) and rated output
shift (±0.003% RO/°F Nominal). Shall not exceed
0.50% RO referenced at +75°F (24°C).
Custom Ranges Available!
High Accuracy
Rugged Sputtered Strain
Gauge Design
All Stainless Steel
Construction
Isolated 0 to 5 VDC Output
Internal Shunt Resistor to
Simulate Transducer Output
Proven Performance in
Extreme Applications
Connections
A + 5 VDC
B - 5 VDC
C - 28 VDC
D + 28 VDC
E Shunt
F Shunt
Connector end
short pins E and
F to simulate
transducer
pressure output
DIMENSIONS: IN (MM)
Model 6SE01079
Shown Smaller Than
Actual Size
.50 (12) HEX DEPTH
2.0
(51)
MAX.
0.745 TYP.
FITTING END 7/16-20 UNJF-3B
PER MIL MS-33649-04
DUST PLUG
4.0 MAX
(102)
BENDIX PYGMY CONNECTOR
PT1H-10-6PIN(101) OR EQUAL
MATING CONNECTOR IS
PT06A-10-6S(SR) OR EQUAL
0.05 (12) TYP.
SEAL SCREW, TYP.
SP
A
N
O
ZER
One Omega Drive | Stamford, CT 06907 | 1-888-TC-OMEGA (1-888-826-6342) | info@omega.com
www.omega.com
UNITED KINGDOM
www. omega.co.uk
Manchester, England
0800-488-488
UNITED STATES
www.omega.com
1-800-TC-OMEGA
Stamford, CT.
CANADA
www.omega.ca
Laval(Quebec)
1-800-TC-OMEGA
GERMANY
www.omega.de
Deckenpfronn, Germany
0800-8266342
Karviná, Czech Republic
FRANCE
www.omega.fr
Guyancourt, France
088-466-342
CZECH REPUBLIC
www.omegaeng.cz
596-311-899
BENELUX
www.omega.nl
Amstelveen, NL
0800-099-33-44
More than 100,000 Products Available!
Temperature
Calibrators, Connectors, General Test and Measurement
Instruments, Glass Bulb Thermometers, Handheld Instruments
for Temperature Measurement, Ice Point References,
Indicating Labels, Crayons, Cements and Lacquers, Infrared
Temperature Measurement Instruments, Recorders Relative
Humidity Measurement Instruments, RTD Probes, Elements
and Assemblies, Temperature & Process Meters, Timers and
Counters, Temperature and Process Controllers and Power
Switching Devices, Thermistor Elements, Probes and
Assemblies,Thermocouples Thermowells and Head and Well
Assemblies, Transmitters, Wire
Flow and Level
Air Velocity Indicators, Doppler Flowmeters, Level
Measurement, Magnetic Flowmeters, Mass Flowmeters,
Pitot Tubes, Pumps, Rotameters, Turbine and Paddle Wheel
Flowmeters, Ultrasonic Flowmeters, Valves, Variable Area
Flowmeters, Vortex Shedding Flowmeters
pH and Conductivity
Conductivity Instrumentation, Dissolved Oxygen
Instrumentation, Environmental Instrumentation, pH
Electrodes and Instruments, Water and Soil Analysis
Instrumentation
Data Acquisition
Auto-Dialers and Alarm Monitoring Systems,
Communication Products and Converters, Data
Acquisition and Analysis Software, Data Loggers
Plug-in Cards, Signal Conditioners, USB, RS232, RS485
and Parallel Port Data Acquisition Systems, Wireless
Transmitters and Receivers
Pressure, Strain and Force
Displacement Transducers, Dynamic Measurement
Force Sensors, Instrumentation for Pressure and Strain
Measurements, Load Cells, Pressure Gauges, Pressure
Reference Section, Pressure Switches, Pressure Transducers,
Proximity Transducers, Regulators,
Strain Gages, Torque Transducers, Valves
Heaters
Band Heaters, Cartridge Heaters, Circulation Heaters,
Comfort Heaters, Controllers, Meters and Switching
Devices, Flexible Heaters, General Test and Measurement
Instruments, Heater Hook-up Wire, Heating Cable
Systems, Immersion Heaters, Process Air and Duct,
Heaters, Radiant Heaters, Strip Heaters, Tubular Heaters
click here to go to the omega.com home page