High Accuracy:
to 0.1% of Span
Single and Dual
Setpoint Models
1.0° and 0.1° ModelsAdjustable
Proportion Band
Bright LED Display
The OMEGA®4200A Series is an ideal controller for RTD applications. This quality-built linearized instrument is available in both 1.0° and 0.1° resolution models. Higher accuracies, 5 to 10 times greater than the typical 1% meter indicating controller, are achieved through a unique linearizing technique.
Bright, easy-to-read LED digits present an unambiguous temperature indication. Accuracy is enhanced through 3-wire lead compensation—a feature allowing the sensor to be up to 305 m (1000') from the controller. The standard unit includes adjustable proportional band, manual reset, plus a metal
1
4 DIN case with full plug-in construction, allowing front removal of the control unit without disturbing the case and its rear wiring. The series 4200A controllers are available in single or dual setpoint models with relay output as a standard. Triac or 4 to 20 mA optional outputs are offered on the first setpoint at no additional cost. Truly a superior controller at a remarkably low price.
Model 4201A Single Setpoint Proportional Controller
This versatile digital controller can be operated as a proportional controller with the adjustable bandwidth up to 3% of full span. The setpoint temperature is always available. Simply push the spring-loaded setpoint switch to the
4202APF2, $435, shown smaller than actual size.
right, and the setpoint is digitally displayed. To change the setpoint, with the switch deflected to the right, adjust the knob to the right of the switch until you get the desired reading. The standard Model 4201 has an internal SPDT relay (7 A resistive at 120 Vac). This model is also available with optional Triac or 4 to 20 mA output in place of the relay. See Options and Specifications for more information.
Model 4202A Dual Setpoint Controller
The first setpoint of the Model 4202A incorporates the same features as the Model 4201A and also can be ordered with the optional Triac or 4 to 20 mA output. The second setpoint may be set at any value within the full span of the controller. It energizes an SPDT internal relay (3 A resistive 120 Vac) which can be used as either an on-off control, a high-limit alarm, or a low-limit alarm. For an alarm with latching features, an external latching relay and push button to reset are suggested. The second setpoint is set and displayed using the same procedure as for the Model 4201A except the switch is deflected to the left and the left adjustment knob is used.
P-47
Option “T” Triac Output
Option “T” replaces the relay output on the first setpoint with a solid state plug-in Triac which yields time-proportional or on-off switching. The Triac is rated at 1 A continuous and 10 A in rush for both 120 and 240 Vac service. For higher amperage loads the Triac may be used to drive higher rating solid state relays or mechanical contractors. Specify option “T” after the model number when ordering, no additional charge.
Option “F” (4 to 20 mA Output)
This option is applicable to the first setpoint only and is used to drive proportioning devices such as SCR power controller, motor positioners, or electropneumatic actuators. The 4 to 20 mA dc output signal can be connected to a maximum of 1000 Ω resistance load. This signal is 20 mA at the low temperature end of the proportional band and is decreased linearly through the band to 4 mA at the high temperature end. If the driven device is not isolated (ungrounded) an ungrounded sensor must be used with the Series 4200A which is designed for only one ground in the system. Specify option “F” after the model number when ordering, no additional charge.
U
p to 3.2 (0.12)
Panel Thickness
MTG. Slide
9
1
(3.58)
S
quare
96
(3.78)
9
7
(3.81)
92
(
3.62)
P
anel
Cutout
9
2 (3.62)
96 (3.78)
118 (4.64)
MTG. Slide in Place
R
educe Length for Panels Greater Than 3
.2 (0.12)
(Optional)
Set Point II Adj.
Output Light
(
Set Point II)
Output Light
(Set Point I)
Manual Reset Adj.
— +
Door
Plug-in Module Removal Screws
Narrow Wide
Proportional Band Adj.
O
verrange Indication - 3 Digit
(Decimal Point)
S
et Point II Adj.
Set Point Selector Switch
Set II
Set I
Read
305
°F
M
inimum center distance
b
etween units: 100 (3.93)
vertical & horizontal
E
xtended Warranty
Program
SM
OMEGACARESMextended warranty program
is available for models shown on this page.
Ask your sales respresentative for full details
when placing an order. OMEGACARE
SM
covers parts, labor and equivalent loaners.
Specifications*
RTD Input
Type: 100 Ω platinum;
alpha = 0.00385 (DIN curve)
Configuration: 3 wire
xternal Lead Wire Resistance
E Effect: 0.1% span up to 10 ohms per
lead wire leg
Sensor Break Protection:
Built-in, upscale on open sensor
Calibration Accuracy:
1.0° Resolution Model:
±0.1% of span ±1 digit
0.1° Resolution Model:
±0.2% of span ±1 digit
Stability: 0.1% for 30 to 130°F,
0.1% +10% to 15% line voltage Common Mode Rejection: Max error ±1°C with 240V, 60 Hz applied as common mode signal between sensor input and chassis ground
Series Mode Rejection:
Max error ±1°C with series mode signal of 100 mV PK-to-PK at 60 Hz
Control Output
1st Setpoint (Adjustable Time Proportional):
Relay (Standard Model): SPDT relay
7 A resistive at 120 Vac, 5 A resistive at 240 Vac Option “T” (Triac): Solid state plug-in triac rated 1 A holding and 10 A in-rush
Option “F” (Current Proportional):
4 to 20 mA (dc) into 1000 Ω max
2nd Setpoint:
Relay (On-off Only): SPDT,
rated 3 A at 120 Vac
Dimensions: mm (in)
Adjustments
Proportional Band (Gain): 0 to
3% of span, or on-off; selectable
Manual Reset (Offset): Adjustable Cycle Time: Automatically adjusts
with load requirement to give least wear with minimum ripple (10 sec. minimum total time)
Display and Indications
Temperature: Filtered LED, 3 or
1
2 digits, 2 readings per second update;
3 readability is 1.0° or 0.1° (°F or °C), depending on model Setpoint: By spring loaded switch, first or second setpoint is displayed in place of temperature; setpoint adjusted by 25 turn pot.; 1.0° or 0.1° setability Outputs: LED indication for both first and second setpoints; LED are “on” when output drive signal present; “on-off” indication on relay and triac model; proportional intensity for option “F.”
Temperature Overrange:
Red LED indication
Setpoint
Resolution: 1.0° or 0.1° (°F or °C),
depending on model
Repeatability: ±0.1% to ±0.2% of span Adjustment: By 25 turn pot.;
see “Setpoint” under “Display and Indication” section. Power: 120/240 Vac (+10%, -15%, 50/60 Hz). Power consumption less than 5 watts
Environmental & Physical
Operating Temperature: -1 to 54°C
(30 to 130°F)
Weight: 1 kg (2 lb)
1
4 DIN Case: Metal, full plug-in with
screw terminal on rear. Adjustable brackets for panel mounting; panel cutout is 92 x 92 mm (3.622 x 3.622")
Specifications and configurations subject to
*
change as advances in technology allow.
MOST POPULAR MODELS HIGHLIGHTED!
Sensor Accuracy Number of
Model No. Price Type Range Resolution ±1 Digit Setpoints
4201APF1 4201APC1 0 to 600°C 1°C
4202APF1 4202APC1 0 to 600°C 1°C
4201APF2 4201APC2 -199.9 to 199.9°C 0.1°C
4202APF2 4202APC2 -199.9 to 199.9°C 0.1°C
Accessories
Model No. Price Description DPP-6 $575
GE-1315 55 Reference Book: Instrument Loop Diagrams
Comes complete with operator’s manual.
Ordering Examples: 4202APF1, RTD digital controller, $470. OCW-3, OMEGACARESMextends standard 2-year warranty to a total of 5 years,
$435
470
435
470
Platinum RTD
ohm/ohms/°C
1
4
100 ohm
α = 0.00385
DIN panel punch
($118) $470 + 118 = $588. 4201APC2, RTD digital controller, $435.
0 to 999°F 1°F
0 to 999°F 1°F
-199.9 to 199.9°F 0.1°F
-199.9 to 199.9°F 0.1°F
P-48
±0.1%
of Span
±0.2%
of Span
Single
Dual
Single
Dual
P