Omega Products 1827FMA5445ST User Manual

ECONOMICAL GAS MASS FLOW CONTROLLERS
For Clean Gases With Optional Integral Display
FMA5400 Series
Standard
U NIST-Traceable
Calibration
U Reads and Controls
Gas Mass Flow Without Temperature or Pressure Compensation
U Available in Economical
Aluminum or Corrosion-Resistant 316 SS
U Tiltable LCD for
Easy Reading
The FMA5400/5500 Series electronic gas mass flow controllers can control the flow of a wide variety of gases from 10 SCCM up to 1000 SLM. Utilizing heat transfer through a heated tube, the FMA5400/5500 measures gas mass flow rate directly, without needing to compensate for variations in gas temperature or pressure (within stated limits). They are available in an economical aluminum/brass construction for typical gas flows and a 316 SS construction for applications that require more corrosion resistance. The FMA5400 Series without integral display is supplied with both an analog 0 to 5 Vdc and 4 to 20 mA output for remote monitoring; the FMA5500 Series features an integral 3¹⁄₂ digit display and an analog output. The display is tiltable over 90 degrees for viewing convenience and is calibrated to read out directly in SCCM or SLM for nitrogen (other gas calibrations available by special order).
The FMA5400/5500 mass flow controllers feature a built-in electromagnetic valve for maintaining a constant flow rate regardless of variations in inlet or outlet pressures. The setpoint is controlled either locally via a potentiometer accessible through a window in the case or remotely via an analog 0 to 5 Vdc or 4 to 20 mA signal (field selectable).
FMA5512, shown
smaller than
actual size.
The FMA5400/5500 Series controllers require 12 to 15 Vdc power @ 800 mA maximum, which can be supplied by the FMA545PW wall plug-in socket power supply (24 Vdc power input @ 650 mA is available as an option). The electronics are reverse-polarity protected and have a resettable fuse. Model number FMA545C (supplied separately) provides a mating 15-pin “D” connector with
2.4 m (8') of shielded cable for accessing the analog output signals and power input connections. The LCD for the FMA5500 Series is connected to the lower electronics via a modular plug. The LCD can be remotely located by purchasing an FMA18RC remote cable assembly– you must then build your own assembly for panel mounting the LCD.
SPECIFICATIONS
Accuracy: ±1.5% FS, including linearity
over 15 to 25°C (59 to 77°F) and 0.7 to 4.2 kg/cm ±3% FS for units 100 SLM from 0 to 20% of range
Repeatability: ±0.5% of full scale Temperature Coefficient: 0.15% FS/°C Pressure Coefficient:
0.01% FS per psi (0.07 bar)
Maximum Pressure Drop: 50 psid Response Time: 5 seconds to within
±2% of set flow rate over 25 to 100% FS
2
(10 to 60 psia)
D-27
FMA5402ST mass flow controller without display, 316 SS body, shown smaller than actual size.
Maximum Gas Pressure: 35 kg/cm2
gage (500 psig); 1.76 kg/cm (25 psig) optimum Gas and Ambient Temperature: 5 to 50°C (41 to 122°F) Leak Integrity: 1 x 10 helium max to outside environment
Ma terials in Fluid Contact: Aluminum Models:
Anodized aluminum, 316 SS, brass and FKM O-rings
Stainless Steel Models: 316 SS and FKM O-rings
Output Signal:
Linear 0 to 5 Vdc: 1000 V minimum load 4 to 20 mA: 50 to 500 V loop resistance, ±20 mV max noise
Transducer Power: 12 Vdc @ 800 mA standard; 24 Vdc @ 650 mA optional
Turndown Ratio: 50:1 Shipping Weight: 1.8 kg (4 lb) Compliance: EN55011 class 1,
class B; EN50082-1
Minimum Pressure Drop:
SLM psid SLM psid Up to 9 1.1 200 10
10 to 30 3.9 500 12 50 8 1000 15 60 to 100 18.9
Altitude Sensitivity: With horizontal flow path, no shift in calibration up to +20 degree pitch
Gas Relative Humidity: 0 to 70% RH
-7
cc/sec of
Dimensions: cm (inch)
Unit Maximum Lay Length Connection­ Flow Rate with Fittings Maximum Height Maximum Width Compression Fitting
10 SCCM to 10 SLM 16.0 (6.29) 14.2 (5.60) 2.5 (1.00) ¹⁄₄" 15 to 50 SLM 18.3 (7.21) 15.2 (5.98) 3.2 (1.25) ¹⁄₄" 60 to 100 SLM 18.6 (7.33) 15.2 (5.98) 3.2 (1.25) ³⁄₈" 200 SLM 31.2 (12.30) 16.8 (6.60) 4.4 (1.75) ³⁄₈" 500 SLM 31.5 (12.40) 19.2 (7.55) 7.6 (3.00) ¹⁄₂" 1000 SLM 26.7 (10.53) 21.7 (8.56) 10.2 (4.00) ³⁄₄ FNPT
To Order Visit omega.com/fma5400_5500 for Pricing and Details
Model No. Model No. Model No. Model No. Aluminum/Brass Stainless Steel Aluminum/Brass Stainless Steel Body Maximum Body with Display Body with Display Body without Display without Display Flow Rate
FMA5502 FMA5502ST FMA5402 FMA5402ST FMA5504 FMA5504ST FMA5404 FMA5404ST FMA5506 FMA5506ST FMA5406 FMA5406ST
FMA5508 FMA5508ST FMA5408 FMA5408ST 100 SCCM FMA5510 FMA5510ST FMA5410 FMA5410ST 200 SCCM
FMA5512 FMA5512ST FMA5412 FMA5412ST FMA5514 FMA5514ST FMA5414 FMA5414ST FMA5516 FMA5516ST FMA5416 FMA5416ST FMA5518 FMA5518ST FMA5418 FMA5418ST FMA5520 FMA5520ST FMA5420 FMA5420ST FMA5523 FMA5523ST FMA5423 FMA5423ST FMA5524 FMA5524ST FMA5424 FMA5424ST FMA5526 FMA5526ST FMA5426 FMA5426ST FMA5527 FMA5527ST FMA5427 FMA5427ST FMA5528 FMA5528ST FMA5428 FMA5428ST FMA5540 FMA5540ST FMA5440 FMA5440ST FMA5541 FMA5541ST FMA5441 FMA5441ST FMA5542 FMA5542ST FMA5442 FMA5442ST FMA5543 FMA5543ST FMA5443 FMA5443ST FMA5544 FMA5544ST FMA5444 FMA5444ST FMA5545* FMA5545ST* FMA5445* 1827FMA5445ST* 1000 SLM
10 SCCM 20 SCCM 50 SCCM
500 SCCM 1 SLM 2 SLM 5 SLM 10 SLM 15 SLM 20 SLM 30 SLM 40 SLM 50 SLM 60 SLM 80 SLM 100 SLM 200 SLM 500 SLM
D
Accessories
Model No. Description FMA545C Female 15-pin D-connector, 2.4 m (8') of shielded cable FMA545PW Socket plug-in power supply for 100 to 240 Vac FMA545PW-220VAC Socket plug-in power supply for 220 Vac, European plug type FMA18RC10 3.0 m (10') cable for remote LCD mounting FMA18RC25 7.6 m (25') cable for remote LCD mounting
* Comes with 3⁄4 FNPT connections instead of compression fittings. Comes complete with compression fittings, NIST certificate and operator’s manual. Power
supplies sold separately. Flow ranges specified are for nitrogen or air at 20 psig inlet (up to 50 SLM) or 25 psig inlet
60 to 100 SLM units) and 0 psig outlet. When used with other gases, a multiplication factor is used to determine the flow rate, and the digital display must be rescaled in the field.
To request a custom calibration add the gas abbreviation and inlet pressure/outlet pressure as a suffix to the model number.
Calibration are done at ambient temperatures only, 20ºC (70ºF) For 24 Vdc powered units, add suffix “-24VDC” to the model number, no additional cost. For oxygen cleaned units, add suffix “02CLEAN” to model number for additional cost. Ordering Examples: FMA5410–ARGON, 50/0 psig, 70°F calls for an AL/BR body flow
controller without an integral display, calibrated for Argon at 50 psig inlet pressure, 0 psig outlet pressure, 70°F gas temperature, powered by 12 Vdc.
FMA5516, N2 controller with display, and FMA545PW, power supply.
D-28
FMA5512, shown smaller
than actual size.