omega altise
2
Important Safety Instructions
1. Read all instructions.
2. Disconnect the power plug before dismantling, assembling or before cleaning.
3. Avoid touching mobile parts of the fan.
4. Make sure the fan is on a dry and even surface.
5. Never insert fingers, pencils or any other objects through the guards whenever
the power plug is connected, especially while running.
6. The appliance is not intended for use by young children or infirm persons unless
they have been adequately supervised by a responsible person to ensure that
they can use the appliance safely.
7. Young children or infirm persons should be supervised to ensure that they do not
play with the appliance.
8. Do not use the appliance for any other purpose than its intended use.
9. The fan must not be used if the guards are not fastened according to
instructions.
10. When the power cord is damaged, it must be replaced by the manufacturer or its
service agent or a similarly qualified person in order to avoid a hazard.
11. Do not use your appliance with an extension cord unless it has been checked
and tested by a qualified electrician or electrical supplier.
Read all instructions before using this unit. Keep them for future reference.
Specifications
Model
AW40WA
Settings
3 speed
Rated Voltage
220-240V / 50Hz
Fan blade size
40cm
Watts
50W
Tilt action
Tilting fan head
Dimensions (cm)
44 x 19 x 44cm
Oscillation
Oscillating fan head
Controls
Remote Control
Warranty
2 year replacement

omega altise
3
Assembly Instructions
Your Wall Fan has been boxed unassembled to minimize packaging waste. Each
part is designed to fit together and be disassembled easily for cleaning or storage.
Note: Ensure the Wall Fan is disconnected from the power outlet before
commencing assembly.

omega altise
4
Mount the install plate (13) on the wall with three fixing screws (14) provided (Fig. 1).
Hang the motor and base (17) with the hang hook (15) onto the hanging bracket
(Fig.2).
Remove the plastic shaft protector from the motor shaft (10).
Loosen the rear guard securing ring (6) from the motor & housing assembly.
Position the rear guard (8) firmly to the motor & housing assembly and fasten by
turning the rear guard securing ring (6) clockwise tightly.
Push the fan blade (5) along the motor shaft. Fasten securely using the fan blade
securing nut (4) with the spinner by turning anticlockwise. Attach the front guard (2).
Operating Instructions
Remove the cable tie and unravel the cordset before operation.
The fan and motor assembly are attached to a 3-position ratchet. Tilt up or down
until the assembly clicks into the desired position.
Press speed button to adjust between low-medium-high settings.

omega altise
5
Remote Control Battery Compartment
- Ensure batteries are inserted in the correct direction.
- Do not mix battery types.
- When replacing, ensure both batteries are changed simultaneously.
- 2 x AAA size batteries are required
Press the ON/OFF button to switch the fan on and off. When switched on, pressing
the SPEED button will step the fan through the speeds from Low to High and the
appropriate LED light will glow, showing the LED display on fan body.
Press OSC button for oscillating or fixed operation. When first switched on the
MODE LED will glow red indicating that the unit will operate in normal mode. The
timer key adjusts the off timer; you can select timing from 0.5-7.5hrs.
Remote control operations are identical to the functions on the fan control panel.
Press button 1 for a low speed, 2 for a medium speed and 3 for a high speed.
Press 0 to switch the Wall Fan off.
Oscillating
Timer
Sleep-Natural-

omega altise
6
Press the sleep, Nature and Normal mode button to select required mode.
Natural Mode: High alternates between High - Medium and Low speeds.
Medium alternates between Medium and Low speeds.
Low alternates Low and off.
Sleep mode:
- Sleep mode selected on high speed:
The fan will operate at high speed in Nature mode for 30 minutes, then at
medium speed in Nature mode for 30 minutes, and then it will operate at low
speed in Nature mode for remaining time.
- Sleep mode selected on Medium speed:
The fan will operate at medium speed in Nature mode 30 minutes, and then
it will operate at low speed in Nature mode for remaining time.
- Sleep mode selected on Low speed:
The fan will operate at low speed in Nature mode.
Remote control operations are identical to the functions on the fan control panel.

omega altise
7
Care and Maintenance
1. Always disconnect the cord from the electrical outlet when cleaning your fan.
2. Light accumulated dust may be removed from the fan with a soft cloth or vacuum
cleaner using the dusting brush attachment.
3. Wipe the exterior surfaces of the fan occasionally with a cloth moistened (not
dripping wet) with a mild soap solution. Dry the case thoroughly with a soft dry
cloth before operating the fan.
4. Avoid the use of gasoline, benzine, thinner etc as they may result in damage to
the fan.
5. Store the fan in a clean dry place when not in use.
CAUTION! Do not immerse the fan in water or allow water to drip into
the interior of the fan housing as this could create a fire or electric
shock hazard.
WARNING! Do not attempt to open or repair the fan yourself. Doing so
could void the warranty and cause damage or personal injury.
Omega Altise products are distributed in Australia by Hagemeyer Appliances,
(A Division of Hagemeyer Brands Australia Pty Ltd)
ABN 28 001 375 686
Locked Bag 4013, Kingsgrove NSW 2208
Phone: 1300 739 033
Fax: 1800 838 899
Email: customerservice@meaappliances.com.au