Omega RHXL-3SD, ZW-CM, OS-MINIUSB, OS-MINIUSB-SN201, OS-MINIUSB-SN21 Instruction Sheet

DP6-MMLPS1
Power Supply
M4533-0607
O
O
12 VDC OUTPUT @ 400 mA
O
EASILY ATTACHED TO BACK OF DP63000x
UL Recognized Component, File # E313607
DESCRIPTION
The Model DP6-MLPS1 is a +12 VDC power supply designed to attach to the rear of the DP63000x Series. The DP6-MLPS1 can be powered from an 85­250 VAC source.
Caution: The maximum output current of the DP6-MLPS1 is 400 mA. Check the
specifications of the specific counter(s)/indicators(s) and sensors(s) being
used to ensure that total current requirements do not exceed 400 mA.
SAFETY SUMMARY
All safety related regulations, local codes and instructions that appear in the manual or on equipment must be observed to ensure personal safety and to prevent damage to either the instrument or equipment connected to it. If equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.
DIMENSIONS In inches (mm)
SPECIFICATIONS
1. POWER REQUIREMENTS: 85-250 VAC, 50/60 Hz, 14 VA.
2. POWER OUTPUT: +16 VDC max @ 4 mA
11.5 VDC min @ 400 mA
3. ENVIRONMENTALCONDITIONS:
Operating Temperature: 0 to 60°C Storage Temperature: -30 to 75°C Operating and Storage Humidity: 85% max. (non-condensing) from 0°C
to 50°C.
Altitude: Up to 2000 meters
4. CERTIFICA TIONS AND COMPLIANCES:
SAFETY
UL Recognized Component, File # E313607, UL 61010-1, CSA C22.2
No. 61010-1 Recognized to U.S. and Canadian requirements under the Component
Recognition Program of Underwriters Laboratories, Inc.
Output meets Class 2 power requirements per UL 1310.
IEC 61010-1, EN 61010-1: Safety requirements for electrical
equipment for measurement, control, and laboratory use, Part 1.
ELECTROMAGNETIC COMPATIBILITY
Emissions and Immunity to EN 61326: Electrical Equipment for
Measurement, Control and Laboratory use.
Notes:
1. Criterion A: Normal operation within specified limits.
2. Criterion B: Temporary loss of performance from which the unit self­recovers.
5. CONSTRUCTION: High impact black plastic. Mounting hardware
included. Installation Category II, Pollution Degree 2.
6. CONNECTION: Two position terminal block which accepts one 14 AWG
wire (torque terminal screws to 5 inch-lbs. [0.56 N-m]).
7. WEIGHT: 2 oz (47 g)
CAUTION: Read complete instructions prior
to installation and operation of the unit.
CAUTION:
Risk of electric shock.
Class BEN 55011
Emissions:
0.5 cycle
Criterion A 3 V/rms Criterion A
EN 61000-4-6 EN 61000-4-11
RF conducted interference Voltage dip/interruptions
1 kV L-L,
Criterion BEN 61000-4-5Surge
1 kV signal
2 kV power
Criterion AEN 61000-4-4Fast transients (burst)
1 kV signal
2 kV L&N-E power
10 V/m
Criterion AEN 61000-4-3Electromagnetic RF fields
8 kV air discharge
4 kV contact discharge
Criterion AEN 61000-4-2Electrostatic discharge
Immunity to Industrial Locations:
LP0696X
INSTRUCTION
SHEET
Shop online at: omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info
INSTALLATION ENVIRONMENT
The unit should be installed in a location that does not exceed the maximum operating temperature and provides good air circulation. Placing the unit near devices that generate excessive heat should be avoided.
Installation Procedure
The DP6-MLPS1 is shipped with all the necessary hardware to mount to the rear of an installed DP63000x. Refer to the instructions that correspond to your unit for proper installation.
TROUBLESHOOTING
For further technical assistance, contact technical support at the appropriate
company numbers listed.
The user must remove the common and V+ screw terminals on the rear of the DP63000x. Install the 3/16" hex drive stand-offs into the common and V+ terminals. The DP6-MLPS1 is then mounted to the stand-offs using the supplied screws and square washers. AC power can then be connected to the terminal block of the DP6-MLPS1.
WARRANTY/DISCLAIMER
OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 25 months from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month grace period to the normal two (2) year product warranty to cover handling and shipping time. This ensures that OMEGA’s customers receive maximum coverage on each product.
If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer Service Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of having been damaged as a result of excessive corrosion; or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating conditions outside of OMEGA’s control. Components in which wear is not warranted, include but are not limited to contact points, fuses, and triacs.
OMEGA is pleased to offer suggestions on the use of its various products. However, OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by the company will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of OMEGA with respect to this order, whether based on contract, warranty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event shall OMEGA be liable for consequential, incidental or special damages.
CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical applications or used on humans. Should any Product(s) be used in or with any nuclear installation or activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility as set forth in our basic WARRANTY/DISCLAIMER language, and, additionally, purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product(s) in such a manner.
RETURN REQUESTS/INQUIRIES
Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return package and on any correspondence. The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in transit.
OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords our customers the latest in technology and engineering. OMEGA is a registered trademark of OMEGA ENGINEERING, INC. © Copyright 2006 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without the prior written consent of OMEGA ENGINEERING, INC.
FOR WARRANTY RETURNS, please have the following information available BEFORE contacting OMEGA:
1. Purchase Order number under which the product was PURCHASED,
2. Model and serial number of the product under warranty, and
3. Repair instructions and/or specific problems relative to the product.
FOR NON-
WARRANTY REPAIRS, consult OMEGA for current repair charges. Have the following information available BEFORE contacting OMEGA:
1. Purchase Order number to cover the COST of the
repair,
2. Model and serial number of the product, and
3. Repair instructions and/or specific problems
relative to the product.
Where Do I Find Everything I Need for
Process Measurement and Control?
OMEGA…Of Course!
Shop online at omega.com
TEMPERATURE
] Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies ] Wire: Thermocouple, RTD & Thermistor ] Calibrators & Ice Point References ] Recorders, Controllers & Process Monitors ] Infrared Pyrometers
PRESSURE, STRAIN AND FORCE
] Transducers & Strain Gages ] Load Cells & Pressure Gages ] Displacement Transducers ] Instrumentation & Accessories
FLOW/LEVEL
] Rotameters, Gas Mass Flowmeters & Flow Computers ] Air Velocity Indicators ] Turbine/Paddlewheel Systems ] Totalizers & Batch Controllers
pH/CONDUCTIVITY
] pH Electrodes, Testers & Accessories ] Benchtop/Laboratory Meters ] Controllers, Calibrators, Simulators & Pumps ] Industrial pH & Conductivity Equipment
DATA ACQUISITION
] Data Acquisition & Engineering Software ] Communications-Based Acquisition Systems ] Plug-in Cards for Apple, IBM & Compatibles ] Datalogging Systems ] Recorders, Printers & Plotters
HEATERS
] Heating Cable ] Cartridge & Strip Heaters ] Immersion & Band Heaters ] Flexible Heaters ] Laboratory Heaters
ENVIRONMENTAL MONITORING AND CONTROL
] Metering & Control Instrumentation ] Refractometers ] Pumps & Tubing ] Air, Soil & Water Monitors ] Industrial Water & Wastewater Treatment ] pH, Conductivity & Dissolved Oxygen Instruments
Loading...