Omega TXDIN1600T User guide

Page 1
Shop online at
omega.com
For latest product manuals:
www.omegamanual.info
SM
TXDIN1600T
DIN Rail Transmitter
Page 2
Servicing North America:
U.S.A. Omega Engineering, Inc. Headquarters: Toll-Free: 1-800-826-6342 (USA & Canada only)
Customer Service: 1-800-622-2378 (USA & Canada only) Engineering Service: 1-800-872-9436 (USA & Canada only) Tel: (203) 359-1660 Fax: (203) 359-7700 e-mail: [email protected]
For Other Locations Visit omega.com/worldwide
The information contained in this document is believed to be correct, but OMEGA accepts no liability for any errors it contains, and reserves the right to alter specifications without notice.
Page 3
Instruction Manual
Omega TXDIN1600T User Guide V1
1
TXDIN1600T / Signal Conditioner for RTD, Thermocouple & Sli
IMPORTANT - CE & SAFETY REQUIREMENTS
Important - Potentially Hazardous situations. Persons responsible for the installation and operation of this equipment must be fully aware of all aspects of this guide. Failure to follow the instructions can cause severe injuries and damage. This product is suitable for environment Installation category II pollution degree. The product is classed as "PERMANENTLY CONNECTED EQUIPMENT", and must be DIN rail mounted, inside a suitable enclosure providing environmental protection to IP65 or greater. DC supply must be derived from a local supply and not a distribution system. To maintain CE EMC requirements, input and supply wires must be less than 30 metres. The product contains no serviceable parts, or internal adjustments. No attempt must be made to repair this product. Faulty units must be returned to supplier for repair. This product must be installed by a qualified person. All electrical wiring must be carried out in accordance with the appropriate regulations for the place of installation. Before attempting any electrical connection work, please ensure all supplies are switched off.
ABSOLUTE MAXIMUM CONDITIONS ( To exceed may cause damage to the unit):-
Supply Voltage Ʋ 50 V dc (Protected for over voltage and reverse connection)
Current with over voltage Ʋ 200 mA
Input Voltage Ʋ 24 VDC, 24 V rms between any terminals
Input Current Ʋ 30 mA between terminals
Ambient Temperature (-30 to 75) ƱC
Humidity (10 to 95) % RH (Non condensing)
RECEIVE AND UNPACKING
Please inspect the packaging and instrument thoroughly for any signs of transit damage. If the instrument has been damaged, please notify your supplier immediately.
dewire sensors
OPERATION (please refer to data sheet for full technical specification.)
Page 4
CONFIGURATION
Omega TXDIN1600T User Guide V1
2
This product is configured using the USB port of a PC running USB_Speed_Link software, available from your suppliers web site. During configuration the product is powered direct from the usb port, removing the need for additional power. If the user wishes to monitor live process data during configuration, then powered must be applied. Note the input and USB port of the device share the same ground, therefore care must be taken to ensure isolation between PC and input circuit. This is best achieved by using a portable laptop or notebook PC. USB_Speed_Link software is provided with detailed help menu to guide the user through the simple configuration procedure. Unless specified at the time of order this product is supplied with the default configuration listed below.
Factory default:
Input Type = PT100 (IEC) Input Range = (-205 to 855) ƱC
Units = " C " Process Output = (0 to 100) ƱC
Output range = (4 to 20) mA Filter = off User offset = 0.0 ƱC
Tag = " " Error Signal = 21.00 mA
MECHANICAL INSTALLATION
ϭ Ϯ ϯ
ϰ ϱ ϲ
ϵϴϳ
ϭϭ ϭϮϭϬ
PP
6W\OH ',1PRGXOHZLGWK 0DWHULDO 3RO\DPLGH VHOIH[WLQJXLVKLQJ 7HUPLQDOV 6FUHZWHUPLQDO &DEOH PP0D[ &RORXU *UH\
PP
PP
DKhEd/E'
^ĐƌĞǁĚƌŝǀĞƌ
EϱϬϬϮϮ/EZ/>
Tϯŵŵ
! ,3
&
&
dKW
dŽĨŝƚŽƌƌĞůĞĂƐĞŵŽĚƵůĞ /ŶƐĞƌƚƐĐƌĞǁĚƌŝǀĞƌŝŶƚŽƐůŽƚĂŶĚůĞǀĞƌůĂƚĐŚĂǁĂLJĨƌŽŵďŽĚLJ
Page 5
ELECTRICAL INSTALLATION
Omega TXDIN1600T User Guide V1
3
78512))6833/<%()25(:25.,1*21$1<(/(&75,&$/&211(&7,21 6833/<,629(592/7$*(3527(&7('$1')86(':,7+$1,17(51$/5(6(77$%/()86(
&211(&7,21 )RUFDEOHOHQJWK0HWUHVQRVFUHHQRUWZLVWSDLUUHTXLUHG 8VHUHFRPPHQGHGW\SHVIRUFDEOHOHQJWKWRPHWUHV
,QSXW:LUHV
5HVLVWDQFHVOLGH WKHUPRFRXSOHZLUH 6FUHHQHG&DEOH
2XWSXW:LUHV
6FUHHQHGFDEOHRU WZLVWHGSDLU
1RWH
2SHQFLUFXLW VLJQDOGHWHFWLRQ LVQRW DYDLODEOH RQP9,QSXW3LQV
6KRUWFLUFXLWP9,QSXW3LQV ZLOOUHDG P$DW, QSXW
/EWhd
ZĞƐŝƐƚĂŶĐĞ^ůŝĚĞǁŝƌĞ
^ůŝĚĞtŝƌĞ
dŚĞƌŵŽĐŽƵƉůĞ;ŵsͿ
KhdWhd
ϵ
ϴ
ϳ
ϵ
ϳ
ϴ
н
ϴ
ϳ
sŽůƚĂŐĞ
ϰ
ϱ
н
s
ŽƵƚ
Ͳ
ŵ;/ŶƚͿ
ϯ
ϲ
н
Ͳ
ŵ;džƚͿ
н
ϲ
ϱ
Ͳ
sƐ
^hWW>z
ϭ
Ϯ
6FUHZ'ULYHU
н
sĚĐ
Ͳ
sĂĐ
PP
Page 6
WARRANTY/DISCLAIMER
OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 61 months from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month grace period to the normal five (5) year product warranty to cover handling and shipping time. This ensures that OMEGA’s customers receive maximum coverage on each product.
If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer Service Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of having been damaged as a result of excessive corrosion; or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating conditions outside of OMEGA’s control. Components in which wear is not warranted, include but are not limited to contact points, fuses, and triacs.
OMEGA is pleased to offer suggestions on the use of its various products. However, OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by the company will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of OMEGA with respect to this order, whether based on contract, warranty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event shall OMEGA be liable for consequential, incidental or special damages.
CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical applications or used on humans. Should any Product(s) be used in or with any nuclear installation or activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility as set forth in our basic WARRANTY/DISCLAIMER language, and, additionally, purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product(s) in such a manner.
RETURN REQUESTS/INQUIRIES
Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return package and on any correspondence.
The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in transit.
FOR WARRANTY RETURNS, please have the following information available BEFORE contacting OMEGA:
1. Purchase Order number under which the product was PURCHASED,
2. Model and serial number of the product under warranty, and
3. Repair instructions and/or specific problems
relative to the product.
OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords our customers the latest in technology and engineering.
OMEGA is a registered trademark of OMEGA ENGINEERING, INC. © Copyright 2016 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied,
reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without the prior written consent of OMEGA ENGINEERING, INC.
FOR NON-WARRANTY REPAIRS, consult OMEGA for current repair charges. Have the following information available BEFORE contacting OMEGA:
1. Purchase Order number to cover the COST of the repair,
2. Model and serial number of the product, and
3. Repair instructions and/or specific problems relative to the product.
Page 7
Where Do I Find Everything I Need for
Process Measurement and Control?
OMEGA…Of Course!
Shop online at omega.com
TEMPERATURE
MU
Thermocouple, RTD & Thermistor Probes, Connectors,
Panels & Assemblies
MU
Wire: Thermocouple, RTD & Thermistor
MU
Calibrators & Ice Point References
MU
Recorders, Controllers & Process Monitors
MU
Infrared Pyrometers
PRESSURE, STRAIN AND FORCE
MU
Transducers & Strain Gages
MU
Load Cells & Pressure Gages
MU
Displacement Transducers
MU
Instrumentation & Accessories
FLOW/LEVEL
MU
Rotameters, Gas Mass Flowmeters & Flow Computers
MU
Air Velocity Indicators
MU
Turbine/Paddlewheel Systems
MU
Totalizers & Batch Controllers
SM
pH/CONDUCTIVITY
MU
pH Electrodes, Testers & Accessories
MU
Benchtop/Laboratory Meters
MU
Controllers, Calibrators, Simulators & Pumps
MU
Industrial pH & Conductivity Equipment
DATA ACQUISITION
MU
Communications-Based Acquisition Systems
MU
Data Logging Systems
MU
Wireless Sensors, Transmitters, & Receivers
MU
Signal Conditioners
MU
Data Acquisition Software
HEATERS
MU
Heating Cable
MU
Cartridge & Strip Heaters
MU
Immersion & Band Heaters
MU
Flexible Heaters
MU
Laboratory Heaters
ENVIRONMENTAL MONITORING AND CONTROL
MU
Metering & Control Instrumentation
MU
Refractometers
MU
Pumps & Tubing
MU
Air, Soil & Water Monitors
MU
Industrial Water & Wastewater Treatment
MU
pH, Conductivity & Dissolved Oxygen Instruments
M5635/1216
Loading...