Omega SV240, SV250, SV260, SV270 Specification

Page 1
3- AND 4-WAY SOLENOID VALVES
DIRECT-ACTING OR PILOT-OPERATED, NORMALLY OPEN OR CLOSED, BRASS VALVE BODY
SV240 Series 3-Way General Purpose SV250 Series 3-Way Switchable NO/NC SV260 Series 3-Way Quick Exhaust SV270 Series 4-Way General Purpose
U General Purpose, Quick
Exhaust, and Selectable NO/NC Models
U Rugged NEMA 4 (IP65)
Housing
U Mounts in Any Position U Rated for Continuous Duty
TYPICAL APPLICATIONS
U Mobile Equipment U Gas Sampling U Compressors U Ball Valve Actuators U Cylinders U Dispensing U Laundry Equipment U Machine Tool Equipment
The SV241, SV242, and SV261 Series valves are 3-way, direct­acting, and normally closed. The SV241 and SV242 can be used for liquids or gases, while the SV261 offers a quick-exhaust feature and is limited to air use. The most common application for these 3-way valves is the control of single-acting cylinders or spring-return actuators. The pressure inlet port is blocked in the de-energized position.
A 3-way normally closed valve has 3 ports labeled 1, 2, and 3. When de-energized, no flow occurs from port 1, but there is flow from port 2 to 3. When energized, flow occurs from port 1 to 2, but no flow occurs
from port 3. Usually, 3-way valves are used to control larger pneumatically activated valves. Port 1 is connected to the pressure source, port 2 is connected to the cylinder controlling the pneumatic activation, and port 3 is the exhaust port vented to the room.
The SV251 is a multipurpose 3-way valve and can be used as normally open
SV251 shown larger than actual size.
L-39
SV271 shown larger than actual size.
SV242 shown larger than actual size.
SV261 shown larger than actual size.
or normally closed. During installation, for normally closed select port 1 as supply pressure. Port 2 is connected to the pneumatic cylinder, and port 3 is the exhaust port. To configure as normally open, select port 3 as supply pressure. Port 2 is connected to the pneumatic cylinder, and port 1 is the exhaust port. The SV251 can be used for liquids or gases.
The SV271 is a 4-way, 5-ported solenoid valve, rated for air applications only. It is a 2-position, pilot-operated valve typically used to control double­acting cylinders or pneumatic actuators. A 4-way valve has ports labeled 1, 2, 3, 4, and
Page 2
DIRECT-ACTING OR PILOT-OPERATED, NORMALLY
41
(1.62)
1
#8-32 UNC TH’D
X 0.18 DP
2 PLCs
8
(0.33)
17
(0.67)
44
(1.73)
1/2 NPT
70
(2.76)
50
(1.95)
36
(1.43)
64
(2.50)
90
(3.55)
17
(0.67)
22
(0.87)
3
3
1
2
3
1
2
41
(1.62)
2
1
#8-32 UNC TH’D
X 0.18 DP
2 PLCs
8
(0.33)
17
(0.67)
44
(1.73)
1/2 NPT
70
(2.76)
50
(1.95)
36
(1.43)
64
(2.50)
90
(3.55)
17
(0.67)
22
(0.87)
3
3
1
2
3
1
2
41
(1.62)
3
25 (0.98)
70
(2.76)
50
(1.95)
0
36 (1.43)
69
(2.73)
82
(3.24)
25 (1.00)
3
0.43 0.75
1.34
1.97
2
1.97
1.34
3
1
0
2
70
(2.76)
94
(3.70)
50
(1.95)
60
(2.36)
23
(0.91)
11
38
(1.45)
35 (1.36)
1/8-27 NPT
5 PLCs
70
(2.76)
50
(1.95)
36
(1.43)
64
(2.50)
90
(3.55)
17
(0.67)
22
(0.87)
3
3
1
2
70
(2.76)
50
(1.95)
0
69
(2.73)
82
(3.24)
3
3
1
0
2
OPEN OR CLOSED, BRASS VALVE BODY, 3- OR 4-WAY SOLENOID VALVES
5. When de-energized, pressure is supplied to port 1, which is open to cylinder port 4 and closed to cylinder port 2. Port 4 is closed to exhaust port 3. When energized, pressure port 1 is closed to cylinder port 4 and open to cylinder port 2. Cylinder port 2 is closed to exhaust port 3. Cylinder port 4 is open to exhaust port 5.
41
(1.62)
2
44
(1.73)
To Order
NPT MODEL NO. FITTING ORIFICE Cv SEAL MIN MAX °C (°F) OPEN CLOSE
3-Way General Purpose, Direct Acting, Normally Closed, Brass Body
SV241 SV242
3-Way Selectable Service, Direct Acting, User-Selectable NO or NC, Brass Body
SV251 3-Way Quick Exhaust, Pilot Operated, Normally Closed, Brass Body, Air Only SV261
4-Way General Purpose, Pilot Operated, Normally Closed, Aluminum Body, Air Only
SV271
ACCESSORIES
MODEL NO. DESCRIPTION
SVCOIL-110AC Replacement coil, 110 Vac
3
41
(1.62)
SV241 and SV242
#8-32 UNC TH’D
1
8
(0.33)
17
(0.67)
25 (0.98)
1
1
1
1
1
X 0.18 DP
2 PLCs
SV261
⁄
4
⁄
4
⁄
4
⁄
4
⁄
8
1/2 NPT
36 (1.43)
25 (1.00)
5
1
,
⁄
⁄
64
8
3
9
,
⁄
⁄
32
64
5
5
,
⁄
⁄
64
64
3
1
,
⁄
⁄
32
4
5
0.35 Buna-N 15 150 74 (165) 10 to 30 ms 10 to 30 ms
⁄
32
SPECIFICATIONS
Operation:
SV241, SV242 and SV251: Direct acting SV261, SV271: Pilot operated
Wetted Parts: Brass, stainless steel, copper and seal SV241: Also Delrin SV271: Aluminum, Delrin, stainless steel, copper and seal
70
(2.76)
50
(1.95)
64
(2.50)
3
22
(0.87)
69
(2.73)
90
(3.55)
82
(3.24)
18
(0.71)
18 (0.71)
36
(1.43)
17
(0.67)
70
(2.76)
50
(1.95)
3
0.17, 0.31 FKM 0 150 116 (240) 10 ms 10 ms
0.24, 0.38 FKM 0 100 116 (240) 10 ms 10 ms
0.17, 0.17 FKM 0 100 116 (240) 10 ms 10 ms
0.20, 1.1 Buna-N 2 100 85 (185) 15 ms 45 ms
0
41
(1.62)
2
44
(1.73)
SV271
5
27 (1.06)
1
3
12 (0.47)
14 (0.55)
(1.57)
DIFF PRES (psid)
Medium: Liquid or gases as specified in
“To Order” chart
Max Static Pressure: 5 times max psid Ambient Temp: -9 to 50°C (15 to 122°F) Mounting: Pipe mounting, any direction Power: 10 W, 120 Vac coils, 50 to 60 Hz
SV251
1/2 NPT
#8-32 UNC TH’D
1
(0.33)
(0.67)
40
8
17
4
2
X 0.18 DP
2 PLCs
18
(0.71)
(0.35)
0.22 DIA THRU
14
(0.55)
(3.70)
9
2 PLCs
(2.76)
94
36
(1.43)
70
50
(1.95)
Dimensions: mm (inch)
TEMP RESPONSE TIME
SVCOIL-220AC Replacement coil, 220 Vac SVCOIL-24VDC Replacement coil, 24 Vdc
Note: Some solenoid valves are available with 24 Vdc coils. Five piece minimum order. UL approval is not available with 24 Vdc coils. Specifications effected; pressure rating may decrease; coil wattage ratings may increase. Consult Engineering.
Ordering Examples: SV251, 3-way direct-acting valve, user-selectable NO/NC with brass body and SV271, 4-way general purpose, pilot operated, NC with aluminum body
1
NPT fitting and Buna-N seal.
⁄
8
L-40
1
NPT fitting with FKM seal.
⁄
4
(1.95)
17
(0.67)
(1.45)
81
(3.20)
50
38
70
(2.76)
64
(2.50)
3
(0.87)
35 (1.36)
1/8-27 NPT
5 PLCs
23
(0.91)
11
(0.45)
22
90
(3.55)
(2.36)
60
VALVES AND REGULATORS
L