Omega OSXL653, OSXL650 User Manual

WITH BUILT-IN
PAT EN T E D
LASER CIRCLE
SIGHTING
TM
omega.com
e-mail: info@omega.com
omegamanual.info
User’s Guide
Shop online at
OSXL650
and OSXL653
Low Cost Professional
Infrared Thermometer
Servicing North America:
U.S.A.: One Omega Drive, Box 4047
ISO 9001 Certified
Stamford, CT 06907-0047 Tel: (203) 359-1660
FAX: (203) 359-7700 e-mail: info@omega.com
Canada: 976 Bergar
Laval (Quebec) H7L 5A1, Canada Tel: (514) 856-6928 FAX: (514) 856-6886 e-mail: info@omega.ca
For immediate technical or application assistance:
U.S.A. and
Canada:
Sales Service: 1-800-826-6342/1-800-TC-OMEGA
®
Customer Service: 1-800-622-2378/1-800-622-BEST
®
Engineering Service: 1-800-872-9436/1-800-USA-WHEN
®
Mexico: En Espa n˜ol: (001) 203-359-7803
FAX: (001) 203-359-7807 e-mail: espanol@omega.com info@omega.com.mx
Servicing Europe:
Czech Republic:
Frystatska 184, 733 01 Karviná, Czech Republic Tel: +420 (0)59 6311899 FAX: +420 (0)59 6311114 Toll Free: 0800-1-66342 e-mail: info@omegashop.cz
Germany
Austria
Daimlerstrasse 26, D-75392 Deckenpfronn, Germany Tel:+ 49 (0)7056 9398-0 FAX: +49 (0)7056 9398-29 Toll Free in Germany: 0800 639 7678 e-mail: info@omega.de
United
Kingdom:
One Omega Drive, River Bend Technology Centre
ISO 9002 Certified
Northbank, Irlam, Manchester M44 5BD United Kingdom Tel: +44 (0)161 777 6611 FAX: +44 (0)161 777 6622 Toll Free in United Kingdom: 0800-488-488 e-mail: sales@omega.co.uk
OMEGAnet®On-Line Service Internet e-mail
omega.com info@omega.com
It is the policy of OMEGA Engineering, Inc. to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification. The information contained in this document is believed to be correct, but OMEGA accepts no liability for any errors it contains, and reserves the right to alter specifications without notice.
WARNING:
These products are not designed for use in, and
should not be u
sed for, human applications.
4-4 Advanced Functions
2
3
3
3
4 6
6
6
7
7 10 10
11 11
12
1-3 Warnings and Cautions
7.Emissivity Table
i
Low Cost Professional Infrared Thermometer
NOTES:
Low Cost Professional Infrared Thermometer
(OSXL653).
larger than the unit’s optical field of view.
Patented laser circle sighting.
Low Cost Professional Infrared Thermometer
Audible alarms (OSXL653).
Temperature data storge (OSXL653).
You may receive harmful laser radiation exposure if you do not adhere to the warnings listed below:
• Use of controls or adjustments or performance of procedures other than those specified here may result in hazardous radiation exposure.
• Do not look at the laser beam coming out of the lens or view directly with optical instruments - eye damage can result.
• Use extreme caution when operating the laser sighting.
• Never point the laser beam at a person.
• Do not attempt to open the thermometer. There are no user serviceable parts.
• Keep out of the reach of all children.
Refer to the inside back cover for product warning label.
2
1-3 Warnings and Cautions
CAUTION
Low Cost Professional Infrared Thermometer
3
Low Cost Professional Infrared Thermometer
-32 to 538°C (-25 to 1000°F)
From -32 to -20°C (-25 to -4°F)
From -20 to 100°C (-4 to 212°F)
100 to 538°C (-212 to 1000°F)
YES - Laser Circle Max//Min/Avg/ T YES (OSXL653) Auto-measuring YES
Data Storage 10 points (OSXL653) Audible Alarm YES (OSXL653)
0 to 50°C (32 to 212°F)
10 to 90%RH
Adj. 0.1 to 1.0 (OSXL653).
0.95 Fixed (OSXL650).
187g Approx.
4
to
Low Cost Professional Infrared Thermometer
Wavelength (Color): Operating Distance: Up to 10 ft.
Max. Output Optical <1mW at 75°F ambient Power: temperature,
Class II Laser Product European Classification: Class 2, EN60825-1
FDA Classification: Complies with 21 CFR Chapter 1, Subchapter J
Beam Diameter: 5 mm
Beam Divergence: <2mrad
Laser Configuration: Dot and Circle
Power Switch: Slide switch, ON-OFF
Power Indicator: Laser icon on display
Power: Supplied by the thermometer
Identification Label: Located on the right side of the thermometer
Warning and Located on the left side of the Certification Label: thermometer
630 to 670 nanometers (red)
3.Specifications con’t.
Laser Sighting
5
Low Cost Professional Infrared Thermometer
Optical Lens
ID and Field
of View Label
Laser Circle
Sighting
LCD displays either the current temperature in degree Celsius or Fahrenheit. The unit will HOLD the last reading for about 6 seconds after the trigger is released; the word HOLD appears. Make sure the target area is larger than the field of view of this instrument. The laser circle sighting indicates the perimeter of the thermometer’s field of view. During the measurement session, the display back light stays on.
6
Low Cost Professional Infrared Thermometer
Complies with 21 CFR, Chapter 1, subchapter J
Laser Aperture
(OSXL653)
(OSXL653)
OSXL653
Laser Warning and
Certification Label
the battery voltage is low and battery symbol appears.
7
Low Cost Professional Infrared Thermometer
8
4-4 Advanced Functions (OSXL653)
4-4-1 AUTO Mode-Continuous Operation
From the SCAN mode (Trigger is pulled), you can lock the trigger electronically and measure temperature continuously (AUTO mode) by pressing the F key. The AUTO icon will appear on the display. Pressing the F key again will disable the AUTO mode. AUTO icon will disappear from the display. If the trigger is pulled, the unit stays in the SCAN mode. If the trigger is released, the unit will go to HOLD mode and will shut itself off after about 6 seconds.
The following table shows an overall functional flow chart of the thermometer:
Mode Press F Key Press Up Key Press Down Key
SCAN SCAN AUTO ---- ---­ AUTO AUTO DATA ---- ---­ DATA DATA Max Temp + Memory - Memory
Location Location Max Temp Max Temp Min Temp ---- ---­ Min Temp Min Temp Avg Temp ---- ---­ Avg Temp Avg Temp ∆T ---- ---­ ∆T T Emissivity ---- ---­ Emissivity Emissivity High Alarm + Emissivity – Emissivity HAL High Alarm Low Alarm + Alarm Set Point – Alarm Set Point LAL Low Alarm SCAN/HOLD + Alarm Set Point – Alarm Set Point
Low Cost Professional Infrared Thermometer
9
4-4-2 Max, Min, Avg, ∆T Temperatures
You can review the Maximum, Minimum, Average, and differential (Max - Min) temperatures on the display by pressing the F key. If the trigger is pulled at the same time, the display will show SCAN icon and all the values are in real time. If the trigger is released, the display will show the HOLD icon and all the values are the last readings before the trigger is released.
4-4-3 Temperature Data Storage & Recall - DATA Mode (OSXL653)
You can store up to 10 temperature data points (Memory Location 0 thru 9). When you are in DATA mode, set the memory location using the Up or Down keys, then pull the trigger. The unit will store the temperature data in the next memory location.
You can review (recall) the stored data by going to the DATA mode using the F key (Trigger is released) and pressing the UP/Down keys. You can then review memory locations 0 thru 9.
The unit stores all temperature data, Emissivity value, high and low alarm set points in the non-volatile memory, Changing the battery will not affect these values.
NOTE
Low Cost Professional Infrared Thermometer
(OSXL653)
distance from the target to the target diameter. When measuring a target temperature, the target area has to be larger than the thermometer field of view (FOV).
10
Low Cost Professional Infrared Thermometer
11
Low Cost Professional Infrared Thermometer
PATENT NOTICE:
U.S. PAT. B1 5,368,392; 5,524,984; 5,727,880; 5,823,678; 5,823,679; 6,123,453; 6,267,500 B1; 6,341,891 B1; 6,377,400 B1; 6,540,398 B2; 6,614,830 B1; 6,633,434 B2; 6,659,639; 6,901,089 B1 / Canada 2,114,806; 2,317,734 / France 2 756 920; 2 767 921; 2 773 213; 2 773 214 / Germany G 94 22 197.9; G 94 22 203.7 / Holland 1007752; / U.K. Registered 2,237,493; 2,320,324;
9726133.3 / EPO 0 644,408 B2; EPO 1085 307 A1. Other U.S. and Foreign Patents Pending.
12
7.Emissivity Table
Low Cost Professional Infrared Thermometer
NOTES:
Low Cost Professional Infrared Thermometer
NOTES:
Low Cost Professional Infrared Thermometer
WARRANTY/DISCLAIMER
OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA’s customers receive maximum coverage on each product.
If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer Service Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of having been damaged as a result of excessive corrosion; or current, heat, moisture or vibration; improper specifica­tion; misapplication; misuse or other operating conditions outside of OMEGA’s control. Components in which wear is not warranted, include but are not limited to contact points, fuses, and triacs.
OMEGA is pleased to offer suggestions on the use of its various products. However, OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by the compamy will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of OMEGA with respect to this order, whether based on contract, warranty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event shall OMEGA be liable for consequential, incidental or special damages.
CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical applications or used on humans. Should any Product(s) be used in or with any nuclear installation or activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility as set forth in our basic WARRANTY / DISCLAIMER language, and, additionally, purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product(s) in
RETURN REQUESTS / INQUIRIES
Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return package and on any correspondence.
The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in transit.
FOR WARRANTY
RETURNS, please have the following information available BEFORE contacting OMEGA:
1. Purchase Order number under
which the product was PURCHASED,
2. Model and serial number of the
product under warranty, and
3. Repair instructions and/or specific
problems relative to the product.
FOR NON-WARRANTY REPAIRS, consult OMEGA for current repair charges. Have the following information available BEFORE contacting OMEGA:
1. Purchase Order number to cover the COST of the repair,
2. Model and serial number of the product, and
3. Repair instructions and/or specific problems relative to the product.
OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords our customers the latest in technology and engineering.
OMEGA is a registered trademark of OMEGA ENGINEERING, INC. © Copyright 2006 OMEGA ENGINEERING, INC. All rights reserved. This docu-
ment may not be copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without the prior written consent of OMEGA ENGINEERING, INC.
Where Do I Find Everything I Need for
Process Measurement and Control?
OMEGA…Of Course!
Shop online at omega.com
TEMPERATURE
䡺⻬
Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies
䡺⻬
Wire: Thermocouple, RTD & Thermistor
䡺⻬
Calibrators & Ice Point References
䡺⻬
Recorders, Controllers & Process Monitors
䡺⻬
Infrared Pyrometers
PRESSURE, STRAIN AND FORCE
䡺⻬
Transducers & Strain Gages
䡺⻬
Load Cells & Pressure Gages
䡺⻬
Displacement Transducers
䡺⻬
Instrumentation & Accessories
FLOW/LEVEL
䡺⻬
Rotameters, Gas Mass Flowmeters & Flow Computers
䡺⻬
Air Velocity Indicators
䡺⻬
Turbine/Paddlewheel Systems
䡺⻬
Totalizers & Batch Controllers
pH/CONDUCTIVITY
䡺⻬
pH Electrodes, Testers & Accessories
䡺⻬
Benchtop/Laboratory Meters
䡺⻬
Controllers, Calibrators, Simulators & Pumps
䡺⻬
Industrial pH & Conductivity Equipment
DATA ACQUISITION
䡺⻬
Data Acquisition & Engineering Software
䡺⻬
Communications-Based Acquisition Systems
䡺⻬
Plug-in Cards for Apple, IBM & Compatibles
䡺⻬
Datalogging Systems
䡺⻬
Recorders, Printers & Plotters
HEATERS
䡺⻬
Heating Cable
䡺⻬
Cartridge & Strip Heaters
䡺⻬
Immersion & Band Heaters
䡺⻬
Flexible Heaters
䡺⻬
Laboratory Heaters
ENVIRONMENTAL MONITORING AND CONTROL
䡺⻬
Metering & Control Instrumentation
䡺⻬
Refractometers
䡺⻬
Pumps & Tubing
䡺⻬
Air, Soil & Water Monitors
䡺⻬
Industrial Water & Wastewater Treatment
䡺⻬
pH, Conductivity & Dissolved Oxygen Instruments
M4297/0706
Loading...