OS541
Infrared Thermometer
CAUTION
LASER RADIATION
DO NOT STARE INTO BEAM
WAVELENGTH 800-700 mm POWER <1mW-CLASS IN LASER PRODUCT, COMPLIES WITH 21
CFR CHAPTER 1, SUBCHAPTER J.
LASER RADIATION­CLASS 2 LASER PRODUCT, CONFORMS TO IEC825-1:1993
MADE IN TAIWAN
Servicing North America:
USA: One Omega Drive, Box 4047
ISO 9001 Certified Stamford CT 06907-0047
Tel: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com
Canada: 976 Bergar
Laval (Quebec) H7L 5A1, Canada Tel: (514) 856-6928 FAX: (514) 856-6886 e-mail: info@omega.ca
For immediate technical or application assistance:
USA and Canada: Sales Service: 1-800-826-6342 / 1-800-TC-OMEGA
®
Customer Service: 1-800-622-2378 / 1-800-622-BEST
®
Engineering Service: 1-800-872-9436 / 1-800-USA-WHEN
®
TELEX: 996404 EASYLINK: 62968934 CABLE: OMEGA
Mexico: En Espan˜ol: (001) 203-359-7803 e-mail: espanol@omega.com
FAX: (001) 203-359-7807 info@omega.com.mx
Servicing Europe:
Benelux: Postbus 8034, 1180 LA Amstelveen, The Netherlands
Tel: +31 (0)20 3472121 FAX: +31 (0)20 6434643 Toll Free in Benelux: 0800 0993344 e-mail: sales@omegaeng.nl
Czech Republic: Frystatska 184, 733 01 Karviná, Czech Republic
Tel: +420 (0)59 6311899 FAX: +420 (0)59 6311114 Toll Free: 0800-1-66342 e-mail: info@omegashop.cz
France: 11, rue Jacques Cartier, 78280 Guyancourt, France
Tel: +33 (0)1 61 37 2900 FAX: +33 (0)1 30 57 5427 Toll Free in France: 0800 466 342 e-mail: sales@omega.fr
Germany/Austria:
Daimlerstrasse 26, D-75392 Deckenpfronn, Germany Tel:+ 49 (0)7056 9398-0 FAX: +49 (0)7056 9398-29 Toll Free in Germany: 0800 639 7678 e-mail: info@omega.de
United Kingdom: One Omega Drive, River Bend Technology Centre
ISO 9002 Certified Northbank, Irlam, Manchester
M44 5BD United Kingdom Tel: +44 (0)161 777 6611 FAX: +44 (0)161 777 6622 Toll Free in United Kingdom: 0800-488-488 e-mail: sales@omega.co.uk
OMEGAnet®On-Line Service Internet e-mail
www.omega.com info@omega.com
It is the policy of OMEGA to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification.
The information contained in this document is believed to be correct, but OMEGA Engineering, Inc. accepts no liability for any errors it contains, and reserves the right to alter specifications without notice. WARNING: These products are not designed for use in, and should not be used for, human applications.
CONTENT
Page
I. SAFETY INFORMATION --------------------- 2
II. CAUTIONS --------------------------------------- 2
III. GENERAL SPECIFICATION ---------------- 3
IV. NAME AND FUNCTION ---------------------- 4
V. OPERATION INSTRUCTIONS:
Measuring Trigger ---------------------------- 5
Distance to Spot Ratio (D/S) -------------- 5
Emissivity
-------------------------------------- 5
Maintenance ------------------------------------
Replace Battery
--------------------------------
6
6
Infrared Recorder
I. SAFETY INFORMATION
Read the following safety information carefully before attempting to operate or service the meter.
Only qualified personnel should perform repairs or servicing not covered in this manual.
Periodically wipe the case with a dry cloth. Do not use abrasives or solvents on this instrument.
Safety symbols:
Dangerous, refer to this manual before using the meter.
Apply with European CE.
This instrument conforms to the following standards:
EN50081-1: 1992 Electromagnetic Emissions
EN50082-1: 1997 Electromagnetic Susceptibility
Test were conducted using a frequency range of 80-1000 MHz with the instrument in three orientations. The average error for the three orientations is ± 2.0°C (±4.0°F) at 3V/m throughout the spectrum. However, between 300 MHz and 500 MHz at 3V/m, the instrument may not meet its stated accuracy.
Warning of laser!
Do not point laser directly at human eye or indirectly from reflective surfaces.
II. CAUTIONS
Before using the infrared thermometer you notice the following:
2
Infrared Recorder
Away from electrical welders, induction heaters and EMF sources.
When using this thermometer under large or abrupt ambient temperature changes, allow 15 minutes for unit to stabilize before use.
Do not keep this thermometer in the environment of high temperature for a long time.
Keep away from dusty environment, and keep in carry case after operation to avoid contamination of optical lenses.
III. GENERAL SPECIFICATION
Display: 4 digit LCD Display Illumination: Field of View: 8:1 Target Indicator: Emissivity: Power Off: Temperature Range: Accuracy: ±2°C(4°F) or ±2% of reading Resolution: 0.5°C / 0.5°F Repeatability: Within ±1% of reading or ±1°C(2°F) Storage Condition: -10~60°C, 14~140°F, ≤ 75%RH Operating Condition: 0~40°C, 32~104°F, 10~90%RH Response time: 0.5 second Battery: 9V battery, 006P, IEC6F22, NEDA1604 Battery Life: Approximately:15 hrs Dimension: 157.5x115x36mm, 17.5x4.5x1.4inch Weight: 180g Approx. Accessory:
Backlight by LED
Laser spot
0.98
Automatic power-off after 10 seconds
-20~500°C -4~932°F
(Alkaline)
9V battery, instruction manual, carrying case
3
IV. NAME AND FUNCTION
Infrared Recorder
1
2
LASER
ON C
34
FOFF
1
Laser dot/circle switch2Infrared sensor aperture
3
Laser on/off switch
5
Measuring Trigger
7
LCD display
LASER RADIATION -
5
6
CAUTION
DO NOT STARE INTO BEAM
OUTPUT < 1mW AT 630 670mm
CLASS II LASER PRODUCT
4
6
7
OPEN
°C/°F switch
Battery cover
LCD Display
Scan indication
Laser on
indication
Low battery
Digital value
indication
SCAN HOLD
Data Hold indication
Temperature unit indication
4
SCAN
Infrared Recorder
V. OPERATION INSTRUCTIONS
• Measuring Trigger
To measure a temperature, point the unit at an object and pull the trigger. Be sure to consider distance-to-spot size ratio and field of view. The laser is used for aiming the target for reference. When the laser is on, you can switch between laser dot and circle by moving a lever in front of optics. Laser dot is an indication of the center of the field of view. Laser circle is an indication of the perimeter of the field of view. The temperature reading will be updated on the LCD. When the operator releases the trigger, the reading will automatically be held on the LCD for 10 more seconds. After 10 seconds this thermometer will power down itself to save battery.
• Distance to Spot Ratio (D/S)
You have to make sure that the detection area you want to measure is larger than the required spot size to get a correct reading. The temperature you get is an average temperature of the detected region. The smaller the target, the shorter distance is required for the measuring.  (Please refer to the diagram on the side of the unit)
Distance : Spot = 8 : 1
5222
200
400
Measuring Distance
Unit : mm
113
800
Spot Size
5
Infrared Recorder
• Emissivity
Emissivity is a term used to describe the energy-emitting characteristics of materials. The higher of this value means the more capability of radiation emittance the materials has. Most organic materials and painted or oxidized surfaces have an emissivity of 0.98. Metal surfaces or shiny materials has a lower emissivity and give inaccurate readin gs . P le ase n ote t his d uring applications.
• Maintenance
Blow off loose particles using a lens blow. Gently brush remaining debris away with a lens brush. Carefully wipe the surface with a moist cotton swab. The swab may be moistened with water. NOTE: Don't use solvents to clean the glass lens.
• Replace Battery
When the battery voltage drops below that required for reliable operatio n , the l ow ba tt e r y sy mbol wil l appe ar, indi c ati n g i t is the tim e to replace the battery. To ch an ge th e 9 V ba tt e ry , detach the battery compartment cover by pushing the engraved pattern on the handle and pull down. Change the 9V battery wi th new one and put th e battery cover back.
6
LASER RADIATION -
OUTPUT < 1mW AT 630 670mm
CAUTION
DO NOT STARE INTO BEAM
CLASS II LASER PRODUCT
OPEN
WARRANTY/DISCLAIMER
OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA’s customers receive maximum coverage on each product. If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer Service Department will issue an Authorized Return (AR) number imme­diately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no charge. OMEGA’s WAR­RANTY does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of having been damaged as a result of excessive corrosion; or current, heat, mois­ture or vibration; improper specification; misapplication; misuse or other operating conditions outside of OMEGA’s control. Components which wear are not warrant­ed, including but not limited to contact points, fuses, and triacs.
OMEGA is pleased to offer suggestions on the use of its various prod­ucts. However, OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by OMEGA, either verbal or written. OMEGA warrants only that the parts manufac­tured by it will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEV­ER, EXPRESS OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMI­TATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of OMEGA with respect to this order, whether based on contract, warranty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the compo­nent upon which liability is based. In no event shall OMEGA be liable for consequential, incidental or special damages.
CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical applications or used on humans. Should any Product(s) be used in or with any nuclear installation or activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility as set forth in our basic WARRANTY/DISCLAIMER language, and, additionally, purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product(s) in such a manner.
RETURN REQUESTS / INQUIRIES
Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return package and on any correspondence. The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in transit.
FOR WARRANTY
RETURNS, please have the following information available BEFORE contacting OMEGA:
1. Purchase Order number under
which the product was PURCHASED,
2. Model and serial number of the
product under warranty, and
3. Repair instructions and/or specific
problems relative to the product.
FOR NON-WARRANTY REPAIRS, consult OMEGA for current repair charges. Have the following information available BEFORE contacting OMEGA:
1. Purchase Order number to cover the COST of the repair,
2. Model and serial number of the product, and
3. Repair instructions and/or specific problems relative to the product.
OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords our customers the latest in technology and engineering. OMEGA is a registered trademark of OMEGA ENGINEERING, INC. © Copyright 2003 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without the prior written consent of OMEGA ENGINEERING, INC.
Where Do I Find Everything I Need for
Process Measurement and Control?
OMEGA…Of Course!
Shop online at www.omega.com
TEMPERATURE

Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies

Wire: Thermocouple, RTD & Thermistor

Calibrators & Ice Point References

Recorders, Controllers & Process Monitors

Infrared Pyrometers
PRESSURE, STRAIN AND FORCE

Transducers & Strain Gages

Load Cells & Pressure Gages

Displacement Transducers

Instrumentation & Accessories
FLOW/LEVEL

Rotameters, Gas Mass Flowmeters & Flow Computers

Air Velocity Indicators

Turbine/Paddlewheel Systems

Totalizers & Batch Controllers
pH/CONDUCTIVITY

pH Electrodes, Testers & Accessories

Benchtop/Laboratory Meters

Controllers, Calibrators, Simulators & Pumps

Industrial pH & Conductivity Equipment
DATA ACQUISITION

Data Acquisition & Engineering Software

Communications-Based Acquisition Systems

Plug-in Cards for Apple, IBM & Compatibles

Datalogging Systems

Recorders, Printers & Plotters
HEATERS

Heating Cable

Cartridge & Strip Heaters

Immersion & Band Heaters

Flexible Heaters

Laboratory Heaters
ENVIRONMENTAL MONITORING AND CONTROL

Metering & Control Instrumentation

Refractometers

Pumps & Tubing

Air, Soil & Water Monitors

Industrial Water & Wastewater Treatment

pH, Conductivity & Dissolved Oxygen Instruments
M3920/1203
Loading...