OS137 SERIES
Miniature Non-Contact Infrared
Temperature Sensor/Transmitter
MADE IN
omega.com
e-mail: info@omega.com
For latest product manuals:
User’s Guide
Shop online at
CAUTION!
– This product is not intended for medical use or use on humans
Servicing North America:
U.S.A.: Omega Engineering, Inc., One Omega Drive, P.O. Box 4047
ISO 9001 Certified Stamford, CT 06907-0047 USA
Toll Free: 1-800-826-6342 TEL: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com
Canada: 976 Bergar
Laval (Quebec), Canada H7L 5A1 Toll-Free: 1-800-826-6342 TEL: (514) 856-6928 FAX: (514) 856-6886 e-mail: info@omega.ca
For immediate technical or application assistance:
U.S.A. and Canada: Sales Service: 1-800-826-6342/1-800-TC-OMEGA
®
Customer Service: 1-800-622-2378/1-800-622-BEST
®
Engineering Service: 1-800-872-9436/1-800-USA-WHEN
®
Mexico: En Español: 001 (203) 359-7803 FAX: (001) 203-359-7807
info@omega.com.mx e-mail: espanol@omega.com
Servicing Europe:
Benelux: Managed by the United Kingdom Office
Toll-Free: 0800 099 3344 TEL: +31 20 347 21 21 FAX: +31 20 643 46 43 e-mail: sales@omega.nl
Czech Republic: Frystatska 184
733 01 Karviná, Czech Republic Toll-Free: 0800-1-66342 TEL: +420-59-6311899 FAX: +420-59-6311114 e-mail: info@omegashop.cz
France: Managed by the United Kingdom Office
Toll-Free: 0800 466 342 TEL: +33 (0) 161 37 29 00 FAX: +33 (0) 130 57 54 27 e-mail: sales@omega.fr
Germany/Austria: Daimlerstrasse 26
D-75392 Deckenpfronn, Germany Toll-Free: 0 800 6397678 TEL: +49 (0) 7059 9398-0 FAX: +49 (0) 7056 9398-29 e-mail: info@omega.de
United Kingdom: OMEGA Engineering Ltd.
ISO 9001 Certified One Omega Drive, River Bend Technology Centre, Northbank
Irlam, Manchester M44 5BD England Toll-Free: 0800-488-488 TEL: +44 (0)161 777-6611 FAX: +44 (0)161 777-6622 e-mail: sales@omega.co.uk
OMEGAnet®Online Service Internet e-mail
omega.com info@omega.com
It is the policy of OMEGA Engineering, Inc. to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification.
The information contained in this document is believed to be correct, but OMEGA accepts no liability for any errors it contains, and reserves the right to alter specifications without notice. WARNING: These products are not designed for use in, and should not be used for, human applications.
i
OS137 Series Miniature Non-Contact Infrared
Temperature Sensor/Transmitter
Table of Contents
Section Page
Caution & Safety Information ...................................................................... iii
Safety Warnings and IEC Symbols .............................................................. iii
Section 1 Introduction .................................................................................... 1
Section 2 Installation ...................................................................................... 1
2.1 Unpacking .................................................................................. 1
2.2 Electrical Connection ................................................................ 2
Section 3 Operation ......................................................................................... 3
3.1 Measuring Temperature ........................................................... 3
3.2 Ambient Temperature ............................................................... 4
3.3 Atmospheric Quality ................................................................ 4
3.4 Alarm Setting ............................................................................. 6
Section 4 Laser Sight Accessory .................................................................... 7
4.1 Warnings and Caution .............................................................. 7
4.2 Operating the Laser Sight Accessory ..................................... 7
Section 5 Specifications .................................................................................. 9
5.1 General ........................................................................................ 9
5.2 Laser Sight Accessory ............................................................. 10
Section 6 Emissivity Tables .......................................................................... 11
OS137 Series Miniature Non-Contact Infrared Temperature Sensor/Transmitter
ii
Table of Figures
Figure Description Page
2-1 General Wiring Diagram ................................................................ 2
2-2 Alarm Output Wiring Diagram .................................................... 2
3-1 Optical Field of View ...................................................................... 3
3-2 Location of Emissivity & Alarm Adjust and Alarm Switch ......... 3
3-3 Mounting Bracket, OS137-MB ....................................................... 4
3-4 Air Purge Collar, OS137-AP ........................................................... 4
3-5 Stainless Steel Housing .................................................................. 5
3-6 Water/Air Cool Jacket, OS137-WC .............................................. 5
4-1 Laser Sighting Accessory, OS137-LS ............................................. 8
4-2 Laser Warning Label........................................................................ 8
OS137 Series Miniature Non-Contact Infrared Temperature Sensor/Transmitter
iii
CAUTION & SAFETY INFORMATION
If the equipment is used in a manner not specified in this manual, the protection provided by the equipment may be impaired.
The Installation category is one (1).
There is no user replaceable fuse in this product.
The output terminals of this product are for use with equipment (digital meters, chart recorders, etc.) which have no accessible live parts. Such equipment should comply with all the applicable safety requirements.
Do not operate the equipment in flammable or explosive environments.
The unit comes with a 1.82 m (6') shielded cable for power and output connections. The cable is a multi-conductor, 24 AWG stranded wire with the rating of 600 VDC, 205ºC (401°F) Teflon
®
insulation.
Power must be disconnected before making any electrical connections.
The recommended power supply should be VDE or UL approved. Rating:12-24 VDC @ 50 mA mininum power with overload protection.
The supply voltage to the transmitter should not exceed 24 VDC.
SAFETY WARNINGS AND IEC SYMBOLS
This device is marked with international safety and hazardous symbols in accordance with IEC1010. It is important to read and follow all the precautions and instructions in this manual before operating or commissioning this device as it contains important information relating to safety and EMC. Failure to follow all the safety precautions may result in injury and/or damage to your equipment.
IEC Symbol Description
Caution - Refer to the accompanying document(s).
Direct Current
Laser Symbol
1
SECTION 1 - INTRODUCTION
The OS137 Series is a precision, miniature infrared transmitter. It measures temperature via non-contact, and provides an analog output proportional to the measured temperature. The OS137 Series is offered in three temperature ranges: 0 to 100ºC (32 to 212ºF), -18 to 260ºC (0 to 500ºF) and -18 to 538ºC (0 to 1000ºF). The analog output is offered as 4 to 20 mA, 0 to 5 Vdc, 0 to 10 Vdc, 10 mV/degree C or F, or K type thermocouple.
The unit provides adjustable emissivity from 0.5 to 1.0, 10 to 1 optical field of view, and field adjustable alarm output.
The super-compact design, 25.4 mm OD x 127 mm length (1.0" OD x 5.0" L) is ideal to measure temperature in confined, and hard to reach places. The Stainless Steel housing is NEMA-4 rated. The unit comes standard with a 1.82 m (6') shielded cable.
SECTION 2 – INSTALLATION
2.1 – Unpacking
Remove the packing list and verify that you have received all your equipment. If you have any questions about the shipment, please call OMEGA Customer Service at:
1-800-622-2378 or 203-359-1660. We can also be reached on the internet at www.omega.com email: cservice@omega.com
When you receive the shipment, inspect the container and the equipment for any signs of damage. Note any evidence of rough handling in transit. Immediately report any damage to the shipping agent.
The carrier will not honor any damage claims unless all the shipping materials are saved for inspection. After examination and removal of contents, save packing material and carton in the event that reshipment is necessary.
The following items are supplied in the box:
• The infrared transmitter, OS137 with the 1.82 m (6') shielded cable.
• Two mounting nuts
• The User’s Guide
The following describes the ordering information:
OS137 – * – ** , where
- * means:
-1 : 0 to 100°C (32 to 212ºF) temperature range
-2 : -18 to 260ºC (0 to 500ºF) temperature range
-3 : -18 to 538°C (0 to 1000°F) temperature range
Introduction