OMEGA OM-HL-SH-TH Manual

Page 1
TM
User’s Guide
LOG
Model: OM-HL-SH-TH
Intelligent Data Logger
Shop online at
omega.com
e-mail: info@omega.com
For latest product manuals:
www.omegamanual.info
OM-HL-SH Series
Humidity Data Logger, Handheld
Page 2
omega.com info@omega.com
Servicing North America:
U.S.A.
Headquarters:
Omega Engineering, Inc. Toll-Free: 1-800-826-6342 (USA & Canada only) Customer Service: 1-800-622-2378 (USA & Canada only) Engineering Service: 1-800-872-9436 (USA & Canada only) Tel: (203) 359-1660 Fax: (203) 359-7700 e-mail: info@omega.com
For Other Locations Visit omega.com/worldwide
The information contained in this document is believed to be correct, but OMEGA accepts no liability for any errors it contains, and reserves the right to alter specifications without notice.
Page 3
Table of Contents
OM-HL-SH Series
Table of
Contents
Section
......................................................................................
Page
Section 1 Introduction ........................................................................................ 1
1.1 Introduction ................................................................................. 1
1.2 Features ........................................................................................ 1
1.3 Applications ................................................................................. 1
1.4 Series Data Logger Model .......................................................... 1
1.5 Temperature Data Logger Appearance ................................... 2
1.6 Temperature Data Logger Screen ............................................. 2
1.7 Temperature and Humidity Data Logger Appearance ......... 3
1.8 Temperature and Humidity Data Logger Screen ................... 3
1.9 Button function instructions ....................................................... 3
Section 2 Installation and Instruction ........................................................... 4
2.1 Software Installation ................................................................... 4
2.1.1 The Requirement of the Computer Hardware ............... 4
2.1.2 Install Driver & Software................................................... 4
2.2 How to Read and Configure the Logger ................................. 5
2.2.1 Read and Configure the Logger's Settings ..................... 5
2.2.2 Setting Parameters Description ........................................ 6
2.3 Turn On/Off Logger & Start/Stop Logging ............................ 7
2.4 Download the Logging Data ...................................................... 9
2.5 View Data Sheet ........................................................................... 10
2.6 Exporting Logs from LogPro ..................................................... 10
2.7 Delete Records in the Logger ..................................................... 11
2.8 Check the Save File in File List .................................................. 11
Section 3 Attention ............................................................................................. 12
Section 4 FAQ ...................................................................................................... 12
4.1 LCD Screen Dim .......................................................................... 12
4.2 Data & Time Error ........................................................................ 12
4.3 Software "Runtime Error" .......................................................... 12
4.4 Check COM Port Number ......................................................... 12
Page 4
1
Introduction
Section 1 - Introduction
OM-HL-SH temperature humidity data logger, developed by OMEGA, is
featured with LCD display, elegant appearance, low energy consumption, and
excellent consistency. All the sensors are manufactured in Switzerl and, which
assures quality and stability.
Section 1.2 - Features
• Appearance is small and exquisite, cigarette packet size, easy to use.
• The sensor was produced by Switzerland, high accuracy.
• 2 x AAA Battery can be working 6 months with 25 environment.
(sampling interval is 60 secs, logging interval is 300 secs).
• Host Size(L x H x D): 57mm x 92mm x 20mm.
• LCD Screen Size: 37mm x 17mm.
• Temperature & Humidity External Probe Diameter: 16mm.
• Temperature External Probe Diameter: 6mm.
Section 1.3 - Application
• Transportation.
• Supermarkets.
• Working and Living Areas.
There are no user serviceable parts inside your unit. Attempting to repair or service your unit may void your warranty.
Section 1.4 - Data Logger Model
Model
OM-HL-SH-T
OM-HL-SH-TH
Temperature
Range
-20~70
Humidity
Range
(none)
0~95%RH
NOTE:
Temperature
Accuracy
±0.5
±0.5 ±5%RH
Humidity Accuracy
(none)
Capacity of
Records
43,000
1
Page 5
Introduction
Section 1.5 - Temperature Data Logger Appearance(OM-HL-SH-T)
1
Range : -20~+70
Model: OM-HL-SH-T
Intelligent Data Logger
1.
LCD Screen
2.
LOG/STD Button
3.
MAX/MIN Button
4.
Sensor
5.
Hanger
6.
Label
7.
Battery Cover
8.
USB Port
Section 1.6 - Temperature Data Logger Screen(OM-HL-SH-T)
1
2
3
4
5
1.
Temperature Value
2.
Display the Maximum Value in
MAX MIN
the Memory
3.
Display the Minimum Value in the Memory
4.
Battery Symbol: Please replace the battery when show only one bar.
℃ ℉
USBLOG
9
8
7
6
5. LOG Symbol
6. USB Communication Symbol
7. Display years, month/day, hour/ minute recurrently
8. Fahrenheit Unit
9. Centigrade Unit
2
Page 6
1
Introduction
Section 1.7 - Temperature and Humidity Data Logger Appearance
(OM-HL-SH-TH)
Range : -20~+70/0~95%RH
Model: OM-HL-SH-TH
Intelligent Data Logger
5.
1.
LCD Screen
2.
LOG/STD Button
3.
MAX/MIN Button
4.
Sensor
Hanger
6.
Label
7.
Battery Cover
8.
USB Port
Section 1.8 - Temperature and Humidity Data Logger Screen
(OM-HL-SH-TH)
MAX MIN
%
USBLOG
1.
Temperature & Humidity Value
2.
Display the Maximum Value in the Memory
3.
Display the Minimum Value in the Memory
4.
Battery Symbol: Please replace the battery when show only one bar.
5.
LOG Symbol
6.
USB Communication Symbol
7.
Display years, month/day, hour/ minute recurrently
8.
Humidity Unit
9.
Fahrenheit Unit
10
Centigrade Unit
Section 1.9 - Button function instructions
Switching the read maximum and minimum value.
When device is off, press 5S to enter standby mode and press 3S to enter
recording mode. When device is recording, press 3S can enter standby mode (only enter standby mode), in standby model, press 5S to turn the device off.
3
Page 7
Installation and Instruction
Section 2 - Installation and Instruction
This section will explain how to use the software to upload, read, configure and synchronize the settings, how to turn on/off the logger & enter/exist the logging mode, and how to delete and download the logging data.
Section 2.1 - Software Installation
2.1.1 - The Requirement of the Computer Hardware
1. OS: Windows XP/Vista/8/10 (32/64bit).
2. CPU: 1.6GHz.
3. Physical Memory: 512MB.
4. Hard-drive Space: 4 GB.
5. USB Port: 1.
2.1.2 - Install Driver & Software
2
Note: "If need to install Driver separately, please install 64 bit driver for Windows 64 bit computer
& 32 bit driver for Windows 32 bit computer".
1. Install LogPro Software and Driver together(Default Path: C:\OM-HL Logger).
2. Installation Steps: When enter the software, click the ‘Install LogPro and Driver’ (as below Pic ), and then click the ‘Next ’(5 times), click the ‘Install’, click the ‘Finish’. When entering the LogPro software interface, the installation driver software window will pop up. Click 'Install', and the success of installation will be displayed.
Default installation folderLogPro installation page
Install driverThe successful installed
4
Page 8
2
Installation and Instruction
Section 2.2 - How to Read and Configure the Logger
2.2.1 - Read and Configure the Logger's Settings
1. Turn on and Insert the data logger to the computer¹.
2. Start LogPro software on the PC.
3. From the toolbar select Connect.
4. Load & Read the logger’s current settings.
5. Configure the new settings.
6. Sync the settings & time. (The PC time will be synchronized to the logger
as well.) .
7. From the toolbar select disconnect.
8. Sync the Computer's Data & Time to the Data Logger.
9. Unplug the logger from the computer, and then the logger is in Standby mode.
3
6
4
7
8
5
1. The windows operating system cannot handle USB devices being unplugged and plugged back too fast. When unplugging the logger, wait for about 5 seconds before plugging it in again. If you unplug and plug back a device too quickly, the computer may stop recognizing any USB devices on that port. If this happens you will have to restart the computer. This is a windows USB problem and is not related to LogPro.
5
Page 9
2.2.2 - Setting Parameters Description
A.System
Name usb_logger
SN
Type
Model
Temperature Type
B.Sampling
Logging Interval(Secs)
Sampling Interval (Secs)
C.Storage
HLSHXB0001
Data Logger
USE-TH
C
60
60
Installation and Instruction
2
Logs
Total
D.Offset
CH1
CH2
43000
43000
0.0
0.0
Setting Parameter Text Description Name English letters or numbers Name of the logger
SN
10 characters
Must be the same as the one in the
label of logger Temperature Celsius & Fahrenheit Select the Celsius and Fahrenheit readings Logging Interval (secs) sampling Interval (secs) Logs
Total The total capacity of the logger’s storage
Number from 2 to 86400 Number from 1 to 240 Number from 0 to 43000
Number 43000
Logging frequency
Sampling frequency in LCD screen
The count of records in the memory
Calibration mode: For example, pls fill in 1.5 if the displayed temperature is higher than the
Offset
actual temperature of 1.5 ; fill in -1.5 if the displayed temperature is lower than the actual temperature of 1.5 . If
Input positive number to decrease the
value. Input negative number to increase
the value.
you need toadjust the humidity, do the same, thenumber field is
-100~100.
Calibrate the logger: The logger is factory calibrated to an accuracy given in the device specifications. However, there may be times when you wish to adjust the calibration of your logger. Logpro provides you with the ability to perform a single point offset calibration. This calibration can be used to increase the accuracy of the logger for a restricted data range.
6
Page 10
2
Installation and Instruction
Section 2.3 - Turn On/Off Logger & Start/Stop Logging Under Button to Start Mode
Turn On the Logger - Push “LOG/STD” Button for 5 Secs then LCD display is on.
Model: OM-HL-SH-TH
Intelligent Data Logger
Model: OM-HL-SH-TH
Intelligent Data Logger
Start Logging - WhentheLogger is on and onstand-by(LCD does not have “LOG” logo display),press"LOG/STD"for3seconds,LCDdisplaytime,loosen "LOG/STD" button when the LCD display "3.0",nowtheloggerstartloggingandstoringdata(LCD has “LOG” logo display).
Model: OM-HL-SH-TH
Intelligent Data Logger
Model: OM-HL-SH-TH
Intelligent Data Logger
Model: OM-HL-SH-TH
Intelligent Data Logger
Stop Logging - Whenthelogger isonlogging,press"LOG/STD"for3seconds,LCD displaytime,loosen "LOG/STD" button when the LCD display "3.0",LCD does not have LOG logo displaythentheloggerwillbeonstand-by.
Model: OM-HL-SH-TH
Intelligent Data Logger
7
Model: OM-HL-SH-TH
Intelligent Data Logger
Model: OM-HL-SH-TH
Intelligent Data Logger
Page 11
Installation and Instruction
Turn Off the Logger - Push the“LOG/STD” Button for 5 Secs then LCD display is off.
2
Model: OM-HL-SH-TH
Intelligent Data Logger
Model: OM-HL-SH-TH
Intelligent Data Logger
Model: OM-HL-SH-TH
Intelligent Data Logger
LOG Full - Thedevicewon'trecorddatawhilethememoryisfull,thatyouhaveto downloadthedataanddeleteitbyLogprosoftware,thendevicecanrecordagain.
Model: OM-HL-SH-T
Intelligent Data Logger
Model: OM-HL-SH-TH
Intelligent Data Logger
OM-HL-SH-T LOG Full OM-HL-SH-TH LOG Full
OM-HL-SH-TH LCD Display- Display temperature and humidity recurrently, each display time is 5S.
Model: OM-HL-SH-T
Intelligent Data Logger
Model: OM-HL-SH-TH
Intelligent Data Logger
8
Page 12
2
Installation and Instruction
Section 2.4 - Download the Logging Data
10. Insert the data logger to the computer.
11. Start LogPro software on the PC.
12. From the toolbar select Connect.
13. From the toolbar select Download.
12
13
Once the data is downloaded from the logger to the PC, the log graph will be displayed.
Tips: Press and hold the left mouse button to drag a box, when the left mouse button is released, the graph will be redraw with the data in the selected rectangle area. Click right button, then the graph will be redrawing with all the data in the logs file.
9
Page 13
Section 2.5 - View Data Sheet
Click “Data List” button on the toolbar, and then the data listing window
is shown below. Channel 3 unit is Dew Point. The Value is calculated from temperature & humidity.
Installation and Instruction
2
The data pane lists the data samples collected by the logging device. The column width of each column is adjustable by using the left mouse button and dragging the column the desired width.
Section 2.6 - Exporting Logs from LogPro
Export data list to an Excel file.
Export data list to a PDF file.
Export graph to a BMP file.
10
Page 14
2
Installation and Instruction
Section 2.7 - Delete Records in the Logger
14. From the toolbar select Delete.
14
Section 2.8 - Check the Save File in File list
15. From the toolbar select File List.
16. Click to open the file.
16
15
11
• Double click left mouse button, then the selected file is opened.
• Click right mouse button, a popup menu is shown as below, you can rename or delete or log file.
• The save file is saved in the LogPro software’s installation path in the PC’s hard driver.
Page 15
Attention
• Plastic shell is ABS, flame retartdant, not resistant to acid and alkali.
• If repair is needed, only authorized technician can do the repair.
• The instrument configuration by 2 x AAA Battery (1.5V) is not rechargeable.
• USB power supply (2.7V) cannot let the Data Logger work.
3
Section 4.1 - LCD Screen Dim
Insufficient battery or the environment tmeperature is too low or too high. Solution : In the case of insufficient battery, please replace the battery. If results from environment temperature, please immediately take the logger out of the environment.
Section 4.2 - Data & Time Error
Reason:
• The Battery level is low.
• The Data Logger is not synchronous properties, before start recording.
Solution:
• Replace the battery.
• Please sync the properties, before start recording.
Section 4.3 - Software “Runtime Error”
FAQ
4
Reason:
• OS forbid software creating files.
Solution:
• Run the program (software) as an administrator.
• Install software in D or E drive if available.
• A data logger name cannot contain any of the following characters: \ / :
* ? “ < > |
• Software’s installation path cannot include Chinese character or garbage character.
Section 4.4 - Check COM Port Number
Press “Win” + “R” in keyboard -> Run “devmgmt.msc” to Open “Device Manager” in Windows-> Expand “Ports (COM & LPT)” -> “USB-serial CH340 (COM No.)” is the Data Logger.
12
Page 16
WARRANTY/DISCLAIMER
OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA’s customers receive maximum coverage on each product.
If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer Service Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of having been damaged as a result of excessive corrosion; or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating conditions outside of OMEGA’s control. Components in which wear is not warranted, include but are not limited to contact points, fuses, and triacs.
OMEGA is pleased to offer suggestions on the use of its various products. However, OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by the company will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of OMEGA with respect to this order, whether based on contract, warranty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event shall OMEGA be liable for consequential, incidental or special damages.
CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical applications or used on humans. Should any Product(s) be used in or with any nuclear installation or activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility as set forth in our basic WARRANTY/DISCLAIMER language, and, additionally, purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product(s) in such a manner.
RETURN REQUESTS/INQUIRIES
Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return package and on any correspondence.
The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in transit.
FOR WARRANTY RETURNS, please have the following information available BEFORE contacting OMEGA:
1. Purchase Order number under which the product was PURCHASED,
2. Model and serial number of the product under warranty, and
3. Repair instructions and/or specific problems
relative to the product.
OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords our customers the latest in technology and engineering.
OMEGA is a trademark of OMEGA ENGINEERING, INC. © Copyright 2018 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied,
reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without the prior written consent of OMEGA ENGINEERING, INC.
FOR NON-WARRANTY REPAIRS, consult OMEGA for current repair charges. Have the following information available BEFORE contacting OMEGA:
1. Purchase Order number to cover the COST of the repair,
2. Model and serial number of the product, and
3. Repair instructions and/or specific problems relative to the product.
Page 17
Where Do I Find Everything I Need for
Process Measurement and Control?
OMEGA…Of Course!
Shop online at omega.com
TEMPERATURE
Thermocouple, RTD & Thermistor Probes, Connectors,
Panels & Assemblies
Wire: Thermocouple, RTD & Thermistor Calibrators & Ice Point References Recorders, Controllers & Process Monitors Infrared Pyrometers
PRESSURE, STRAIN AND FORCE
Transducers & Strain Gages Load Cells & Pressure Gages Displacement Transducers Instrumentation & Accessories
FLOW/LEVEL
Rotameters, Gas Mass Flowmeters & Flow Computers Air Velocity Indicators Turbine/Paddlewheel Systems Totalizers & Batch Controllers
pH/CONDUCTIVITY
pH Electrodes, Testers & Accessories Benchtop/Laboratory Meters Controllers, Calibrators, Simulators & Pumps Industrial pH & Conductivity Equipment
DATA ACQUISITION
Communications-Based Acquisition Systems Data Logging Systems Wireless Sensors, Transmitters, & Receivers Signal Conditioners Data Acquisition Software
HEATERS
Heating Cable Cartridge & Strip Heaters Immersion & Band Heaters Flexible Heaters Laboratory Heaters
ENVIRONMENTAL MONITORING AND CONTROL
Metering & Control Instrumentation Refractometers Pumps & Tubing Air, Soil & Water Monitors Industrial Water & Wastewater Treatment pH, Conductivity & Dissolved Oxygen Instruments
M5706/1018
Loading...