Omega OMG-USB-DIO48 User Manual

www.omega.com
e-mail: info@omega.com
User’s Guide
OMG-USB-DIO48
48 Channel Digital I/O Interface Board
Shop online at
Servicing North America:
ISO 9001 Certified Stamford CT 06907-0047
TEL: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com
Canada: 976 Bergar
Laval (Quebec) H7L 5A1, Canada TEL: (514) 856-6928 FAX: (514) 856-6886 e-mail: info@omega.ca
For immediate technical or application assistance:
USA and Canada: Sales Service: 1-800-826-6342 / 1-800-TC-OMEGA
®
Customer Service: 1-800-622-2378 / 1-800-622-BEST
®
Engineering Service: 1-800-872-9436 / 1-800-USA-WHEN
®
TELEX: 996404 EASYLINK: 62968934 CABLE: OMEGA
Mexico: En Espan˜ ol: (001) 203-359-7803 e-mail: espanol@omega.com
FAX: (001) 203-359-7807 info@omega.com.mx
Servicing Europe:
Benelux: Postbus 8034, 1180 LA Amstelveen, The Netherlands
TEL: +31 (0)20 3472121 FAX: +31 (0)20 6434643 Toll Free in Benelux: 0800 0993344 e-mail: sales@omegaeng.nl
Czech Republic: Frystatska 184, 733 01 Karviná, Czech Republic
TEL: +420 (0)59 6311899 FAX: +420 (0)59 6311114 Toll Free: 0800-1-66342 e-mail: info@omegashop.cz
France: 11, rue Jacques Cartier, 78280 Guyancourt, France
TEL: +33 (0)1 61 37 29 00 FAX: +33 (0)1 30 57 54 27 Toll Free in France: 0800 466 342 e-mail: sales@omega.fr
Germany/Austria: Daimlerstrasse 26, D-75392 Deckenpfronn, Germany
TEL: +49 (0)7056 9398-0 FAX: +49 (0)7056 9398-29 Toll Free in Germany: 0800 639 7678 e-mail: info@omega.de
United Kingdom: One Omega Drive, River Bend Technology Centre
ISO 9002 Certified Northbank, Irlam, Manchester
M44 5BD United Kingdom TEL: +44 (0)161 777 6611 FAX: +44 (0)161 777 6622 Toll Free in United Kingdom: 0800-488-488 e-mail: sales@omega.co.uk
OMEGAnet®Online Service Internet e-mail
www.omega.com info@omega.com
It is the policy of OMEGA to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification.
The information contained in this document is believed to be correct, but OMEGA Engineering, Inc. accepts no liability for any errors it contains, and reserves the right to alter specifications without notice. WARNING: These products are not designed for use in, and should not be used for, patient-connected applications.
Manual No. M-3897
Content
INTRODUCTION..........................................................................................................1
OVERVIEW........................................................................................................................1
WHAT S INCLUDED........................................................................................................1
INDUSTRY STANDARD RELAY RACK CABLES AND OPTIONS.................................1
INSTALLATION.......................................................................................................1
TECHNICAL DESC RIPTION.....................................................................................2
SOFTWARE .......................................................................................................................2
RD
3
PARTY SOFTWARE SUPPORT ................................................................................2
ELECTRICAL CHARACTERISTICS..................................................................................3
BANKS AND PORTS.........................................................................................................5
SERIAL STRING ...............................................................................................................5
50 PIN RIBBON CABLE PIN OUT ....................................................................................6
PROGRAMMING ..........................................................................................................7
APPLICATION PROGRAMMERS INTERFACE (API)....................................................7
PRESETTING AN OUTPUT PORT : .................................................................................7
INTERRUPTS: ...................................................................................................................7
PORT CONFIGURATION:.................................................................................................8
RELATIVE ADDRESSING VS. ABSOLUTE ADDRESSING ..............................................9
SPECIFICATIONS......................................................................................................12
ENVIRONMENTAL SPECIFICATIONS..........................................................................12
POWER CONSUMPTION................................................................................................12
MEAN TIME BETWEEN FAILURES (MTBF).............................................................12
APPENDIX A - TROUBLE SHOOTING..................................................................13
APPENDIX B - HOW TO GET ASSISTANCE......................................................14
APPENDIX C - SILK-SCREEN.................................................................................15
APPENDIX D - COMPLIANCE NOTICES.............................................................16
FEDERAL COMMUNICATIONS COMMISSION STATEMENT ....................................16
EMC DIRECTIVE STATEMENT ...................................................................................16
FIGURES
Figure 1- Operating Conditions..........................................................................3
Figure 2- Pull Up Resistors .................................................................................4
Figure 3- Bank and Ports.....................................................................................5
Figure 4- 50 Pin Header/Ribbon Cable Pin out................................................6
Figure 5- Absolute Byte Address (Same for any configuration)...................9
Figure 6- Relative Byte Address (Only applies to the given configuration)9
Figure 7- Absolute Bit Address (Same for any configuration)....................10
Figure 8- Absolute Bit Address (Same for any configuration)....................11
Figure 9- Bit Relative Address (Print and fill in for your configuration).12
Introduction and Installation
Introduction
Overview
The OMG-USB-DIO48 provides six eight-bit ports that may be individually configured as inputs or outputs.
What’s Included
The OMG-USB-DIO48 is ship ped with the following items. If any of these items is missing or damaged, contact the supplier.
OMG-USB-DIO48 Adapter
Software CD
5V Power Supply
USB A to B Cable, Part number CA179
Industry Standard Relay Rack Cables and Options
Part number CA135 for Edge Connection
Part number CA167 for IDC Connection
Part number TB07-50 pin terminal block
Installation
For proper operation install software first. To install the software place the CD in your CD-ROM tray and the auto-run program will start. If auto-run is not available browse the CD and choose “index.htm”. Choose Install Software at the beginning of the CD. Select the Digital I/O software drivers and install SeaIO prior to installing hardware. After installing the software, connect the power adapter and USB cable to the OMG-USB-DIO48. In the event that the hardware is installed first, the “Found new hardware wizard” will request a driver disk. Insert the software CD and browse the SeaIO directory for the “SeaIO.inf” file. A complete installation of the SeaIO suite is recommended by running setup. When plugged in the device will light its enable LED once enumerated properly. Be sure to follow these steps to insure that the
OMG-USB-DIO48 opens and enumerates properly.
OMG-USB-DIO48 Page 1
Technical
Technical Description
The OMG-USB-DIO48 provides 48 channels of digital I/O configurable as inputs or outputs. Applications include PC based control and automation of sensors, switches, satellite antenna control systems, video and audio studio automation, security control systems, and other industrial automation.
Software
The OMG-USB-DIO48 ships with the SeaI/O suite of Windows 98/NT/ME/2000 drivers. SeaI/O provides the user with a consistent and straightforward API, allowing the developer to concentrate on the details of the application as opposed to low level driver development. Popular development environments are supported for application development. SeaI/O includes sample applications and a utility for configuring the driver parameters under Windows, further simplifying installation.
3rd Party Software Support
Third party software support for many HMI/MMI and other process control software is included on the product installation CD. For the most up to date information on third party software support, please visit http://www.omega.com.
OMG-USB-DIO48 Page 2
Technical
Electrical Characteristics
Figure 1, below provides the electrical characteristics of each Input/Output. Each port is buffered with a 74ABT245 octal bi-directional transceiver. Each input is capable of sinking up to 64 mA, while each output can source up to 32 mA. The OMG-USB-DIO48 requires a 5V power source and is shipped with a 5V power supply rated at 2.4 A.
Recommended Operating Conditions
Min Max
Input 0 V 5.25 V
Source 32 mA
Sink 64 mA
Electrical Characteristics
High Level Input Voltage Min 2 V
Low Level Input Voltage Max 0.8 V
High Level Output Voltage
Typically 3.4 V at 3 mA
Low Level Output Voltage Max 0.55 V at 64 mA
Min 2 V at 32 mA
Figure 1- Operating Conditions
OMG-USB-DIO48 Page 3
Loading...
+ 15 hidden pages