www.omega.com
e-mail: info@omega.com
User’s Guide
OMG-USB-232-4
Four Port RS-232 to USB Adaptor
Shop online at
Servicing North America:
USA: One Omega Drive, P.O. Box 4047
ISO 9001 Certified Stamford CT 06907-0047
TEL: (203) 359-1660 FAX: (203) 359-7700
e-mail: info@omega.com
Canada: 976 Bergar
Laval (Quebec) H7L 5A1, Canada
TEL: (514) 856-6928 FAX: (514) 856-6886
e-mail: info@omega.ca
For immediate technical or application assistance:
USA and Canada: Sales Service: 1-800-826-6342 / 1-800-TC-OMEGA
®
Customer Service: 1-800-622-2378 / 1-800-622-BEST
®
Engineering Service: 1-800-872-9436 / 1-800-USA-WHEN
®
TELEX: 996404 EASYLINK: 62968934 CABLE: OMEGA
Mexico: En Espan˜ ol: (001) 203-359-7803 e-mail: espanol@omega.com
FAX: (001) 203-359-7807 info@omega.com.mx
Servicing Europe:
Benelux: Postbus 8034, 1180 LA Amstelveen, The Netherlands
TEL: +31 (0)20 3472121 FAX: +31 (0)20 6434643
Toll Free in Benelux: 0800 0993344
e-mail: sales@omegaeng.nl
Czech Republic: Frystatska 184, 733 01 Karviná, Czech Republic
TEL: +420 (0)59 6311899 FAX: +420 (0)59 6311114
Toll Free: 0800-1-66342 e-mail: info@omegashop.cz
France: 11, rue Jacques Cartier, 78280 Guyancourt, France
TEL: +33 (0)1 61 37 29 00 FAX: +33 (0)1 30 57 54 27
Toll Free in France: 0800 466 342
e-mail: sales@omega.fr
Germany/Austria: Daimlerstrasse 26, D-75392 Deckenpfronn, Germany
TEL: +49 (0)7056 9398-0 FAX: +49 (0)7056 9398-29
Toll Free in Germany: 0800 639 7678
e-mail: info@omega.de
United Kingdom: One Omega Drive, River Bend Technology Centre
ISO 9002 Certified Northbank, Irlam, Manchester
M44 5BD United Kingdom
TEL: +44 (0)161 777 6611 FAX: +44 (0)161 777 6622
Toll Free in United Kingdom: 0800-488-488
e-mail: sales@omega.co.uk
OMEGAnet®Online Service Internet e-mail
www.omega.com info@omega.com
It is the policy of OMEGA to comply with all worldwide safety and EMC/EMI regulations that
apply. OMEGA is constantly pursuing certification of its products to the European New Approach
Directives. OMEGA will add the CE mark to every appropriate device upon certification.
The information contained in this document is believed to be correct, but OMEGA Engineering, Inc. accepts
no liability for any errors it contains, and reserves the right to alter specifications without notice.
WARNING: These products are not designed for use in, and should not be used for, patient-connected applications.
Contents
INTRODUCTION..........................................................................1
OVERVIEW................................................................................................1
WHAT ’S INCLUDED................................................................................ 1
INSTALLATION ..........................................................................2
OPERATING SYSTEM INSTALLATION ................................................. 2
SYSTEM INSTALLATION........................................................................2
CONFIGURATION........................................................................4
ELECTRICAL INTERFACE SELECTION.................................................4
TECHNICAL DESCRIPTION.........................................................5
FEATURES ................................................................................................ 5
RS-232 (DB-9 Male)........................................................................5
SPECIFICATIONS ........................................................................6
ENVIRONMENTAL SPECIFICATIONS....................................................6
MANUFACTURING..................................................................................6
POWER CONSUMPTION..........................................................................6
MEAN TIME BETWEEN FAILURES (MTBF).......................................6
PHYSICAL DIMENSIONS..........................................................................6
APPENDIX A - TROUBLESHOOTING...........................................7
APPENDIX B - HOW TO GET ASSISTANCE................................8
APPENDIX C - ELECTRICAL INTERFACE .....................................9
RS-232.......................................................................................................9
APPENDIX D - ASYNCHRONOUS COMMUNICATIONS ...............10
APPENDIX E - COMPLIANCE NOTICES .....................................11
FEDERAL COMMUNICATIONS COMMISSION STATEMENT ............ 11
CANADIAN RADIO INTERFERENCE REGULATIONS.........................11
EMC DIRECTIVE STATEMENT ........................................................... 12
Figure 1 - Asynchronous Communications Bit Diagram.............................10
Introduction
Introduction
Overview
The OMG-USB-232-4 equips the PC with 4 USB to RS-232 Asynchronous serial
ports providing a versatile interface for common serial needs. The advantage of
this product over more traditional approaches is that it does not require opening
the computer case, nor does it require resources such as I/O ports or IRQ’s. It
does require a system that supports USB both in terms of hardware and
operating system.
What’s Included
The OMG-USB-232-4 is shipped with the following items. If any of these items
is missing or damaged, contact the supplier.
• OMG-USB-232-4 USB to RS-232 Serial I/O Adapter
• USB Cable Part Number CA179 for Connecting to Upstream
Host/Hub
• Software
OMG-USB-232-4 Page 1
Installation
Installation
Operating System Installation
Choose Install Software at the beginning of the CD and install SeaCOM.
System Installation
The screen captures below are taken from a Windows 98 installation. Your
particular operating system may differ slightly from what is shown based on your
version of Windows.
The OMG-USB-232-4 can be connected to any upstream type “A” port either at
the PC host or an upstream hub. The OMG-USB-232-4 is hot pluggable,
meaning there is no need to power down your computer prior to installation.
Connect the OMG-USB-232-4 to an upstream host or hub.
The New Hardware Found wizard will now proceed to locate the appropriate
drivers. These drivers were installed during the SeaCOM software setup
procedure. Once the drivers are found a new window will pop up indicating the
installation of each of the four new ports.
If you view the system’s Device Manager, you should have new “COM” ports in
the Ports (COM & LPT) Device Class. This is shown on the following page.
OMG-USB-232-4 Page 2
Installation
You can access your new COM: ports by using the assigned COM: identifiers as
shown above. In this case, it is COM3, 4, 5 and 6. However, this assignment will
vary from system to system. At this point, the hardware is recognized and ready
to use.
OMG-USB-232-4 Page 3