OMEGA OM-CP-RHTEMP1000IS-A2 Manual

Page 1
OM-CP-RHTEMP1000IS-A2
Xxxxx Xxxxxx
Xxxxx Xxxxxx Xxxxxxxx
M0000/0016
INSTRUCTION
Shop online at omega.comSM e-mail: info@omega.com For latest product manuals: www.omegamanual.info
TM
Intrinsically Safe Temperature and Humidity Data Logger with Stainless Steel Enclosure
MQS5095/0820
800898
Page 2
OM-CP-RHTEMP1000IS-A2
Product Notes
The OM-CP-RHTemp1000IS-A2 carries hazardous location, intrinsically safe certification in accordance with the latest issue of: FM3600, FM3610, CAN/CSA-C22.2 No. 60079-0:15, CAN/CSA-C22.2 No. 60079-11:14
Certified Intrinsically Safe for:
- Class 1 Division 1 Group ABCD
- Class 1 Division 2 Group ABCD
- Temperature Class: T4A
Operational Warnings
- When used in hazardous locations, the OM-CP-RHTEMP1000IS-A2 is to be installed prior to the location becoming hazardous and removed only after the area is no longer hazardous.
- The maximum allowed ambient temperature for the OM-CP-RHTEMP1000IS-A2 (under any circumstances) is 80 °C. The minimum rated operating temperature is -40 °C.
- The OM-CP-RHTEMP1000IS-A2 is approved for use only with the Tadiran TL-2150 battery. Replacement with any other battery will void the safety rating.
- Batteries are user replaceable, but are to be removed or replaced only in locations known to be non­hazardous.
- Tampering or replacement of non-factory components may adversely aect the safe use of the product, and prohibited. Except for replacement of the battery, the user may not service the OM-CP-RHTEMP1000IS-A2. Omega or an authorized representative must perform all other service to the product.
2
Page 3
OM-CP-RHTEMP1000IS-A2
Installation Guide
Installing the Software
Install Omega 4 software (see specifications for compatible versions) and USB Drivers onto a Windows PC (Windows XP SP3 or later). Follow the instructions provided in the Installation Wizard.
Installing the Interface Cable
- OM-CP-IFC400 or OM-CP-IFC406 Follow the instructions provided in the Installation Wizard to install the USB Interface Drivers.
Device Operation
Connecting and Starting the Data Logger
- Once the software is installed and running, plug the interface cable into the docking station (OM-CP-IFC400 or OM-CP-IFC406).
- Connect the USB end of the interface cable into an open USB port on the computer.
- Place the data logger into the docking station.
- The data logger will automatically appear under Connected Devices within the software.
- For most applications, select “Custom Start” from the menu bar and choose the desired start method, reading rate and other parameters appropriate for the data logging application and click “Start”. (“Quick Start” applies the most recent custom start options, “Batch Start” is used for managing multiple loggers at once, “Real Time Start” stores the dataset as it records while connected to the logger.)
- The status of the device will change to “Running”, “Waiting to Start” or “Waiting to Manual Start”, depending upon your start method.
- Disconnect the data logger from the docking station and place it in the environment to measure.
Note: The device will stop recording data when the end of memory is reached or the device is stopped, unless user selectable memory wrap is enabled. At this point the device cannot be restarted until it has been re-armed by the computer.
Stopping and Downloading Data from the Data Logger
- Place the logger into the docking station (OM-CP-IFC400 or OM-CP-IFC406).
- Highlight the data logger in the Connected Devices list. Click “Stop” on the menu bar.
- Once the data logger is stopped, with the logger highlighted, click “Download”. You will be prompted to name your report.
- Downloading will ooad and save all the recorded data to the PC.
Communication To ensure desired operation of the OM-CP-RHTEMP1000IS-A2, please keep the surface clear of any foreign objects or substances. The OM-CP-RHTEMP1000IS-A2’s data is downloaded through external contact with the OM-CP-IFC400 or OM-CP-IFC406 docking station. Covering the surface with foreign objects (i.e. Calibration Labels) can prevent the communication and/or downloading process.
3
Page 4
OM-CP-RHTEMP1000IS-A2
Product Maintenance
Battery Replacement
Materials: Replacement Battery Tadiran TL-2150 (OM-CP-BAT113)
- Observe Operational Warnings when removing and replacing the battery.
- Unscrew the bottom of the logger and remove the battery.
- Place the new battery into the logger. Caution: Observe correct battery polarity when installing.
- Screw the cover back onto the logger.
O-Rings
O-Ring maintenance is a key factor when properly caring for the OM-CP-RHTEMP1000IS-A2. The O-Rings ensure a tight seal and prevent liquid from entering the inside of the device.
Recalibration
Recalibration is recommended annually for any Omega data logger; a reminder is automatically displayed in the software when the device is due.
Still need help? For more troubleshooting tips and information, refer to the built in help section visit us online at www.omega.com
or contact us for support at 1 (800) 872-9436.
4
Page 5
OM-CP-RHTEMP1000IS-A2
OM-CP-RHTEMP1000IS-A2 General Specifications
Description OM-CP-RHTEMP1000IS-A2
Temperature Sensor Resistance Temperature Detector (RTD)
Temperature Range -40 °C to +80 °C (-40 °F to +176 °F)
Temperature Resolution 0.01°C (0.018 °F)
Calibrated Accuracy ±0.5 °C (0 °C to ±50 °C), ±0.9 °F (32 °F to 122 °F)
Humidity Sensor Capacitive Polymer
Humidity Range 0 %RH to 100 %RH (non-condensing)
Humidity Resolution 0.1 %RH
Calibrated Accuracy ±3.0 %RH maximum
Specified Accuracy Range
Memory 32,768 Readings
Start Modes Software programmable immediate or delay start, up to 24 months in advance
Real Time Recording May be used with PC to monitor and record data in real time
Reading Rate 1 reading every second up to 1 reading every 24 hours
Lethality Equations
Calibration Digital calibration through software
Calibration Date Automatically recorded within device and displayed in software
Time Accuracy 16 seconds / month -40 °C to 80 °C
Data Format Date and time stamped ºC, ºF, K, ºR; %RH, mg/mL, Dew Point
Required Interface Package OM-CP-IFC400 or OM-CP-IFC406
Battery Type
Baud Rate 125,000 baud
Typical Battery Life 2 years typical at 15 minute reading rate
Operating System
Compatibility
Omega Software
Compatibility
Operating Environment -40 °C to +80 °C (-40 °F to +176 °F), 0 %RH to 100 %RH (case properly sealed)
Material 316 Stainless Steel/Radel
IP Rating Not Rated - Caution: Do not submerge this product to retain IS rating
Dimensions 1.67 in x 0.97 in dia. (42.3 mm x 24.6 mm dia.)
Weight 2.4 oz (68 g)
Approvals
25 %RH to 75 %RH, +20 °C to +40 °C (68 °F to 104 °F) Hysteresis Error 1 % Typical, 3 % Maximum
Sterilization Units and Pasteurization Units are available within software with a click of a button
Tadiran TL-2150 (OM-CP-BAT113) 3.6 V lithium battery included, user replaceable in a non-hazardous location
Windows XP SP3 7/8/10 or later
Standard Software version 4.2.19.1 or later Secure Software version 4.2.18.0 or later
CE FM Class 3600, Rev. Jan 2018 FM Class 3610, Rev. Jan 2018 CAN/CSA-C22.2 No. 60079-0:15 CAN/CSA-C22.2 No. 60079-11:14
BATTERY WARNING: Fire, explosion, and severe burn hazard. Do not short circuit, charge, force over discharge,
disassemble, crush, penetrate or incinerate. Battery may leak or explode if heated above 80 °C (176 °F).
5
Specifications subject to change. See Omega’s terms and conditions at www.omega.com
Page 6
omega.com info@omega.com
TM
Servicing North America:
U.S.A. Omega Engineering, Inc. Headquarters: Toll-Free: 1-800-826-6342 (USA & Canada only)
Customer Service: 1-800-622-2378 (USA & Canada only) Engineering Service: 1-800-872-9436 (USA & Canada only) Tel: (203) 359-1660 Fax: (203) 359-7700 e-mail: info@omega.com
The information contained in this document is believed to be correct, but OMEGA accepts no liability for any errors it contains, and reserves the right to alter specifications without notice.
OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA’s customers receive maximum coverage on each product.
If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer Service Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of having been damaged as a result of excessive corrosion; or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating conditions outside of OMEGA’s control. Components in which wear is not warranted, include but are not limited to contact points, fuses, and triacs.
OMEGA is pleased to offer suggestions on the use of its various products. However, OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by the company will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of OMEGA with respect to this order, whether based on contract, warranty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event shall OMEGA be liable for consequential, incidental or special damages.
CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical applications or used on humans. Should any Product(s) be used in or with any nuclear installation or activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility as set forth in our basic WARRANTY / DISCLAIMER language, and, additionally, purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product(s) in such a manner.
For Other Locations Visit omega.com/worldwide
WARRANTY/DISCLAIMER
RETURN REQUESTS / INQUIRIES
Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return package and on any correspondence.
The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in transit.
FOR WARRANTY RETURNS, please have the following information available BEFORE contacting OMEGA:
1. Purchase Order number under which the product was PURCHASED,
2. Model and serial number of the product under warranty, and
3. Repair instructions and/or specific problems relative to the product.
OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords our customers the latest in technology and engineering. OMEGA is a registered trademark of OMEGA ENGINEERING, INC.
© Copyright 2016 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without the prior written consent of OMEGA ENGINEERING, INC.
FOR NON-WARRANTY REPAIRS, repair charges. Have the following information available BEFORE contacting OMEGA:
1. Purchase Order number to cover the COST of the repair,
2. Model and serial number of the product, and
3. Repair instructions and/or specific problems relative to the product.
consult OMEGA for current