Omega NWHMTSS, NWHIS, NWHOIS Specification

Page 1
PURE WATER, CORROSIVE SOLUTION AND HIGH TEMPERATURE GAS APPLICATIONS
NWHMTSS, NWHIS and NWHOIS Series
U Screw Plug or Flanged
Heater Design
U 3 - 14" Type 304
Stainless Steel Pipe Body, 150 Lb Con struc tion
U 2 - 200 kW U 120, 240 and 480V,
1 & 3 Phase
U General Purpose,
Moisture Resistant/ Explosion Resistant, Explosion Resistant or Moisture Resistant Terminal Enclosure
U 0.475" Dia. Stainless
Steel or INCOLOY Sheath Elements (15 - 50 W/In
2
)
U With & Without
Thermostat
U UL, CSA and Other Third
Party Approval, Listing or Certification Available on Many Models
APPLICATIONS
Pure Water:
Heating of dem iner al ized or de-ionized water that is highly ag gres sive to mild steel.
Mildly Corrosive Solutions: Heat mildly corrosive solutions (pH5 to pH9) using stainless elements and a passivated stainless pipe body.
Highly Corrosive Solutions and Oils: Low watt density
IN COLOY sheath elements coupled with a passivated Stainless Steel pipe body provides long service life when heating highly corrosive solutions and sulfur laden oils.
Steam Superheating: Increase the enthalpy and quality of steam. Smaller units can be used to make up line losses in steam gen er at ing and distribution systems.
High Temperature Gas: INCOLOY el e ments and a Stainless Steel vessel enhance safe operation to nearly 1400°F outlet gas tem per a ture in air, gas or steam superheating ap pli ca tions.
FEATURES
Terminal Enclosures: Standard
stock heater terminal enclosure E1 General Purpose. Moisture Resistant/ Explosion Resistant E2, Explosion Resistant E3 or Moisture Resistant E4 Enclosures are available as assembly stock.
Elements: Sturdy 0.475" Dia. Stainless Steel or INCOLOY sheath elements provide superior strength and rigidity. OMEGALUX elements utilize high quality resistance wire for coil construction. The coil is sur round ed with high purity mag ne sium oxide which is com pact ed to a dense solid to ensure high thermal con duc tiv i ty and dielectric strength.
Corrosion Resistance: NWHMTSS, NWHIS and NWHOIS pipe bodies and all Stainless Steel heating elements are pas si vat ed to provide additional resistance to corrosion.
Flanges: Type 304 Stain less Steel flanges are standard on 3" and larger circulation heaters. Flange dimensions conform to ANSI B16.5 standards. Series NWHMTSS heaters utilize a Stainless Steel screw plug.
Vessels: Pipe body and nozzles are type 304 ASTM A312 ERW Stainless Steel pipe. The end disks are type 304 ASTM A240 Stainless Steel plate. Provided with thermal insulation and painted sheet metal jacket.
Baffle Assemblies: Internal baffle as sem blies are pro vid ed for model GCHISB-18 heaters to increase the velocity of the air, gas or steam as it passes through the vessel. In creas ing the velocity of the gas helps reduce the tem per a ture of the element sheaths and the vessel walls in critical applications.
Wiring: Wiring terminals are spaced to provide proper arcing and creepage clearances per the NEC. Termination insulators provide electrical isolation between the terminals and the grounded metal sheath to enhance per son­nel safety and equipment service life. Heavy duty jumper straps and other terminal parts assure tight connections and an extra margin of current carrying capacity.
G-33
Controls: All stock and assembly
stock heaters, Series MTSS, 03 and 06, come equipped with mechanical AR thermostats. These thermostats are suitable for most applications. Explosion-resistant and liquid- tight ther mo stats are provided on E2/E3 and E4 units, respectively. Individual product pages list other types of thermostats and controls available for each heater. For heaters listed without controls, refer to the Overview on Mechanical and Electrical Control Options in this section.
Precision Temperature Control and Control Panels: For larger kW
heaters and precise control of gas temperatures in high tem per a ture applications, OMEGALUX
recommends the use of thermocouple sensors, electronic PID temperature controls and SCR power panels for circulation heater applications. The use of electronic and SCR controls will minimize overshoot and reduce the pos si bil i ty of heater damage from overtemperature operation. Integral or remote mounted control panels with electronic controls and solid state (SCR) or contactor power controllers can be provided using virtually any combination of control devices. Consult the Controls section for details.
Page 2
PURE WATER & MILDLY CORROSIVE SOLUTION AP PLI CA TIONS
NWHMTSS Series
U 21⁄2 NPT Stainless Steel
Screw Plug Design
1
⁄2" Passivated
U 2
Stainless Steel Pipe Body, 150 Lb Construction
U 3 - 18 kW U 120, 240 and 480V,
1 & 3 Phase
U General Purpose,
Moisture Resistant/ Explosion Resistant Terminal Enclosure
U Three 0.475" Dia.
Stainless Steel Sheath Elements (50 W/In
U Integral Thermostat
(60 - 250°F)
U UL, CSA and Other Third
Party Approval, Listing or Certification Available on Many Models
APPLICATIONS
Remote and Booster Heating of demineralized or de-ionized water and mildly corrosive solutions (pH5 to pH9).
FEATURES
Terminal Enclosure:
E1 General Purpose is standard. E2 enclosure available.
Elements: Three Type 304 passivated Stainless Steel sheath elements.
Screw Plug: 21⁄2" Type 304 Stainless Steel screw plug with 1⁄2" thermowell for ther mo stat bulb.
Vessel: Pipe body and nozzles are type 304 ASTM A312 ERW Stainless Steel pipe. The end disks are type 304 ASTM A240 or A479 Stainless Steel plate. Provided with thermal insulation and 20 gauge painted sheet metal jacket.
Wiring: Convenient field wiring terminals are provided for easy installation.
Controls: Stock and assembly stock heaters come equipped with integral thermostat.
2
)
Dimensions: inches NWHMTS-03
Integral Thermostat
3/4" Conduit Opening
1" Pipe Outlet
2 Mtg. Lugs Ea. with two 3/8" ­16x1-1/2" Deep Holes on 1-1/4" Centers
1" Pipe Inlet
3/8" NPT Pipe Plug
Note: Add 2" to A dimension for E2 Enclosure.
Dimensions: in
Ckt & Wt. kW Volts Phase A B C Model No. (lb)
3 120 1-1 215⁄8 93⁄8 — NWHMTSS-03-003P-E1/120 15 3 240 1-1 215⁄8 93⁄8 — NWHMTSS-03-003P-E1/240 15 3 240 1-3 215⁄8 93⁄8 — NWHMTSS-03-003P-E1/240/3P 15 3 480 1-1 215⁄8 93⁄8 — NWHMTSS-03-003P-E1/480 15 3 480 1-3 215⁄8 93⁄8 — NWHMTSS-03-003P-E1/480/3P 15
4.5 240 1-1 215⁄8 93⁄8 — NWHMTSS-03-04P5-E1/240 15
4.5 240 1-3 215⁄8 93⁄8 — NWHMTSS-03-04P5-E1/240/3P 15
4.5 480 1-1 215⁄8 93⁄8 — NWHMTSS-03-04P5-E1/480 15
4.5 480 1-3 215⁄8 93⁄8 — NWHMTSS-03-04P5-E1/480/3P 15 6 240 1-1 343⁄4 221⁄2 161⁄2 NWHMTSS-03-006P-E1/240 22 6 240 1-3 343⁄4 221⁄2 161⁄2 NWHMTSS-03-006P-E1/240/3P 22 6 480 1-1 343⁄4 221⁄2 161⁄2 NWHMTSS-03-006P-E1/480 22 6 480 1-3 343⁄4 221⁄2 161⁄2 NWHMTSS-03-006P-E1/480/3P 22 9 240 1-1 343⁄4 221⁄2 161⁄2 NWHMTSS-03-009P-E1/240 22 9 240 1-3 343⁄4 221⁄2 161⁄2 NWHMTSS-03-009P-E1/240/3P 22 9 480 1-1 343⁄4 221⁄2 161⁄2 NWHMTSS-03-009P-E1/480 22 9 480 1-3 343⁄4 221⁄2 161⁄2 NWHMTSS-03-009P-E1/480/3P 22 12 240 1-1 571⁄2 451⁄4 391⁄4 NWHMTSS-03-012P-E1/240 40 12 240 1-3 571⁄2 451⁄4 391⁄4 NWHMTSS-03-012P-E1/240/3P 40 12 480 1-1 571⁄2 451⁄4 391⁄4 NWHMTSS-03-012P-E1/480 40 12 480 1-3 571⁄2 451⁄4 391⁄4 NWHMTSS-03-012P-E1/480/3P 40 15 240 1-1 571⁄2 451⁄4 391⁄4 NWHMTSS-03-015P-E1/240 40 15 240 1-3 571⁄2 451⁄4 391⁄4 NWHMTSS-03-015P-E1/240/3P 40 15 480 1-1 571⁄2 451⁄4 391⁄4 NWHMTSS-03-015P-E1/480 40 15 480 1-3 571⁄2 451⁄4 391⁄4 NWHMTSS-03-015P-E1/480/3P 40 18 240 1-1 571⁄2 451⁄4 391⁄4 NWHMTSS-03-018P-E1/240 40 18 240 1-3 571⁄2 451⁄4 391⁄4 NWHMTSS-03-018P-E1/240/3P 40 18 480 1-1 571⁄2 451⁄4 391⁄4 NWHMTSS-03-018P-E1/480 40 18 480 1-3 571⁄2 451⁄4 391⁄4 NWHMTSS-03-018P-E1/480/3P 40
Ordering Example: NWHMTSS-03­009P-E1/480,
9 kW, 1 phase, 480V heater.
Ordering Information
To Order: Complete the Model Number using the Matrix provided.
Model Pure Water and Mildly Corrosive Solution NWHMT Water Circulation Heater with Screw Plug
SS Stainless Steel Sheath — Stainless Steel Vessel Code Number of Elements
03 Three Code kW 003P 3 009P 9 018P 18
04P5 4.5 012P 12 006P 6 015P 15
Code Terminal Enclosure E1 General Purpose
E2 Moisture Resistant/Explosion Resistant
NWHMTSS 03 003P E1 Typical Model Number
B
9-1/4
3
A
C
7
G
G-34
Page 3
PURE WATER AND MILDLY CORROSIVE SOLUTION AP PLI CA TIONS
NWHIS Series
Dimensions: in
To Order
Ckt & Wt. kW Volts Phase A B C Model No. (lb)
Series 03—3", 150 lb, 304 Passivated Stainless Steel Vessel, 3 INCOLOY Elements
(45 W/in2) with Side Mounted Thermostat (60 to 250°F)—1 NPT Pipe Inlet and Outlet
6 240 1-3 3215⁄16 221⁄2 161⁄2 NWHIS-03-006P-E1/240 70 6 480 1-3 3215⁄16 221⁄2 161⁄2 NWHIS-03-006P-E1/480 70 12 240 1-3 4215⁄16 321⁄2 261⁄2 NWHIS-03-012P-E1/240 80 12 480 1-3 4215⁄16 321⁄2 261⁄2 NWHIS-03-012P-E1/480 80 18 240 1-3 557⁄16 45 39 NWHIS-03-018P-E1/240 98 18 480 1-3 557⁄16 45 39 NWHIS-03-018P-E1/480 98
Series 06—5", 150 lb, 304 Passivated Stainless Steel Vessel, 6 INCOLOY Elements
(45 W/in2) with Side Mounted Thermostat (60 to 250°F)—2 NPT Pipe Inlet and Outlet
24 240 2-3 413⁄4 30 113⁄8 NWHIS-06-024P-E1/240 140 24 480 1-3 413⁄4 30 113⁄8 NWHIS-06-024P-E1/480 140 30 240 2-3 483⁄4 37 141⁄8 NWHIS-06-030P-E1/240 155 30 480 1-3 483⁄4 37 141⁄8 NWHIS-06-030P-E1/480 155 40 240 2-3 601⁄4 481⁄2 205⁄8 NWHIS-06-040P-E1/240 176 40 480 2-3 601⁄4 481⁄2 205⁄8 NWHIS-06-040P-E1/480 176 50 480 2-3 735⁄8 617⁄8 275⁄16 NWHIS-06-050P-E1/240 210
Series 18—8", 150 lb, 304 Passivated Stainless Steel Vessel, 18 INCOLOY Elements (45 W/in2)—21⁄2 NPT Pipe Inlet and Outlet
50 240 3-3 451⁄4 2411⁄16 273⁄16 NWHIS-18-050P-E1/240 396 50 480 3-3 451⁄4 2411⁄16 273⁄16 NWHIS-18-050P-E1/480 396 75 240 3-3 531⁄4 3211⁄16 293⁄16 NWHIS-18-075P-E1/240 414 75 480 3-3 531⁄4 3211⁄16 293⁄16 NWHIS-18-075P-E1/480 414 100 240 3-3 601⁄4 3911⁄16 363⁄16 NWHIS-18-100P-E1/240 425 100 480 3-3 601⁄4 3911⁄16 363⁄16 NWHIS-18-100P-E1/480 425 125 240 3-3 677⁄8 475⁄16 433⁄16 NWHIS-18-125P-E1/240 470 125 480 3-3 677⁄8 475⁄16 433⁄16 NWHIS-18-125P-E1/480 470 150 240 3-3 773⁄8 5613⁄16 535⁄16 NWHIS-18-150P-E1/240 535 150 480 3-3 773⁄8 5613⁄16 535⁄16 NWHIS-18-150P-E1/480 535 175 240 3-3 863⁄8 6513⁄16 625⁄16 NWHIS-18-175P-E1/240 625 175 480 3-3 863⁄8 6513⁄16 625⁄16 NWHIS-18-175P-E1/480 625 200 240 3-3 963⁄8 7513⁄16 725⁄16 NWHIS-18-200P-E1/240 705
200 480 3-3 963⁄8 7513⁄16 725⁄16 NWHIS-18-200P-E1/480 705
Ordering Example: NWHIS-18-050P-E1/240,
50 kW, 240V heater.
Note: Refer to the Controls section online for side mounted controls or control panels.
Ordering Information
To Order— Complete the Model Number using the Matrix provided.
Dimensions: in
Model Pure Water and Mildly Corrosive Solution NWH Water Circulation Heater
IS INCOLOY Elements — Stainless Steel Vessel
Code Number of Elements 03 Three
06 Six 18 Eighteen
Code kW 006P 6 040P 40 150P 150
012P 12 050P 50 175P 175 018P 18 075P 75 200P 200 024P 24 100P 100 030P 30 125P 125
Code Terminal Enclosure E1 General Purpose
E2 Moisture Resistant/Explosion Resistant E3 Explosion Resistant E4 Moisture Resistant
NWH 03 006P E1 Typical Model Number
G-35
NWHIS-03
1" conduit
opening
1" pipe outlet
2 mtg. lugs ea.
3
with two 16 x 11⁄2" deep holes on 11⁄4" centers
1" Pipe Inlet
3
⁄4 NPT
Pipe Plug
NWHIS-06
1" conduit opening
2" pipe outlet
2 mtg. lugs ea.
3
with two
⁄8"­16 x 11⁄2" deep holes on 11⁄4" centers
2" pipe inlet
NWHIS-18
Three 1" conduit openings
1
⁄2" pipe
2 outlet
2 mtg. lugs ea. with
3
⁄4" -
three 10 x 11⁄8" deep holes on 13⁄4" centers
1
2
⁄2" pipe
inlet
NWHIS-AA
Face of
mtg. lugs
3
17
4
7
13
8
⁄8"-
3
⁄8
⁄32
3
⁄4
⁄16
5
71⁄2
A
913⁄16
03 Series 06 Series 18 Series 27 Series
Thermostat
8
4
A
B
C
A
A
1
6
⁄8
13
⁄16
8
C
A
B
25
A
A
Thermostat
3
⁄4 NPT
pipe plug
5
⁄8
8
13
A
Thermostat
(when
specified)
3
⁄4" NPT
pipe plug
Pipe body
B
C
A
A
15
C
L
Page 4
CORROSIVE OIL & HIGHLY CORROSIVE SOLUTION APPLICATIONS
NWHOIS Series
Dimensions (Inches) NWHOIS-03
Thermostat
1" Conduit
Ckt & Wt. kW Volts Phase A B C Model No. (lb)
Series 03 — 3 inch, 150 lb 304 passivated stainless steel vessel, 3 INCOLOY elements
(15 W/In2) with side mounted thermostat (60 to 250°F) — 1" NPT pipe inlet and outlet
2 240 1-3 3215⁄16 221⁄2 161⁄2 NWHOIS-03-002P-E1/240 70 2 480 1-3 3215⁄16 221⁄2 161⁄2 NWHOIS-03-002P-E1/480 70 4 240 1-3 4215⁄16 321⁄2 261⁄2 NWHOIS-03-004P-E1/240 80 4 480 1-3 4215⁄16 321⁄2 261⁄2 NWHOIS-03-004P-E1/480 80 6 240 1-3 557⁄16 45 39 NWHOIS-03-006P-E1/240 98 6 480 1-3 557⁄16 45 39 NWHOIS-03-006P-E1/480 98
Series 06 — 5 inch, 150 lb 304 passivated stainless steel vessel, 6 INCOLOY elements
(15 W/In2) with side mounted thermostat (60 to 250°F) — 2" NPT pipe inlet and outlet
8 240 1-3 413⁄4 30 113⁄8 NWHOISR-06-008P-E1/240 140 8 480 1-3 413⁄4 30 113⁄8 NWHOISR-06-008P-E1/480 140 12 240 1-3 601⁄4 481⁄2 205⁄8 NWHOISR-06-012P-E1/240 176 12 480 1-3 601⁄4 481⁄2 205⁄8 NWHOISR-06-012P-E1/480 176
Series 06 — 5 inch, 150 lb 304 passivated stainless steel vessel, 6 INCOLOY elements
(23 W/In2) with side mounted thermostat (60 to 250°F) — 2" NPT pipe inlet and outlet
25 240 2-3 735⁄8 617⁄8 275⁄16 NWHOIS-06-025P-E1/240 176 25 480 1-3 735⁄8 617⁄8 275⁄16 NWHOIS-06-025P-E1/480 176 30 240 2-3 865⁄8 747⁄8 337⁄8 NWHOIS-06-030P-E1/240 240 30 480 1-3 865⁄8 747⁄8 337⁄8 NWHOIS-06-030P-E1/480 240
Ordering Example: NWHOISR-06-008P-E1/480, 8 kW, 480V heater. Note: Refer to the Controls section online for side mounted controls or control panels.
Ordering Information
To Order — Complete the Model Number using the Matrix provided.
Model Corrosive Oil and Highly Corrosive Solution NWHO Oil Circulation Heater
IS INCOLOY R Reduced Watt Density
Code Number of Elements 03 Three
06 Six
Dimensions: in
Elements — Stainless Steel Vessel
Code kW 002P 2 008P 8 030P 30
004P 4 012P 12 006P 6 025P 25
Code Terminal Enclosure E1 General Purpose
E2 Moisture Resistant/Explosion Resistant E3 Explosion Resistant E4 Moisture Resistant
NWHOIS 03 002P E1 Typical Model Number
Opening
1" Pipe Outlet
2 Mtg. Lugs Ea. with two 3/8" ­16x1-1/2" Deep Holes on 1-1/4" Centers
1" Pipe Inlet
3/4" NPT Pipe Plug
NWHOIS-06
1" Conduit Opening
2" Pipe Outlet
2 Mtg. Lugs Ea. with two 3/8"­16x1-1/2" Deep Holes on 1-1/4" Centers
2" Pipe Inlet
NWHOIS-AA
Face of
Mtg. Lugs
3-3/8
4-17/32
7-3/4
8-13/16
A A
5
6-1/8
7-1/2
8-5/8
C
A
A
03 Series
06 Series
18 Series
27 Series
8
4
C
C
25
Thermostat
3/4" NPT Pipe Plug
Pipe Body
A
B
8-13/16
B
G
A
G-36
Loading...