Omega ILD24-C2 User Manual

SPECIFICATION
Temperature Stability:
50 ppm/°C
Display:
4-digit, 7-segment LED, 57.2mm (2.25”) with red, green and amber programmable colors.
Alarm 1 & 2 programmable, Latch/Unlatch, High, Low, High/Low
SERIAL INTERFACE
Communication Standard:
RS-485, RS-422 or RS-232
Transfer speed (Baud rate):
300, 600, 1200, 2400, 4800, 9600, 19200 bps
Data Format:
7O1-7 bit, Odd, 1 stop bit, 7E1- 7 bit, even, 1 stop bit 8N1 – 8 bit, No parity, 1 stop bit
Multi-Point Address (RS-485):
0 to 199
Flow Control:
No Flow control
Screw terminals for RS-232/485/422 interface
Power Supply:
100-240 Vac ±10%, 50/60 Hz, 22.5 W
Operating Temperature:
0 to 40°C
Storage Temperature:
-20 to 60°C
Relative Humidity:
0 to 85%
Protection:
NEMA-4x (IP65)
Dimensions:
298Lx137Wx73Dmm (11.75" x 5.375" x 2.875")
Panel Cutout:
279.4 L x 116.8 W mm (11.00” L x 4.60” W)
Weight:
1,360 g (3 lbs)
Approvals:
CE per EN61010-1:2001
DISPLAY ABBREVIATIONS
ALR1 Alarm 1 Status OFF Alarm 1 set Off ON Alarm 1 set On A1Md Alarm 1 Mode A1LO Alarm 1 Low A1HI Alarm 1 High A1LH Alarm 1 Low/High LO-1 Alarm 1 Low -999.. Alarm 1 Low Value
..9999
HI-1 Alarm 1 High -999.. Alarm 1 High Value
..9999 A1CR Display color when Alarm 1 triggered GRN Green Color REd Red Color AMbR Amber Color ALR2 Alarm 2 Status OFF Alarm 2 set Off ON Alarm 2 set On A2Md Alarm 2 Mode A2LO Alarm 2 Low A2HI Alarm 2 High A2LH Alarm 2 Low/High LO-2 Alarm 2 Low -999.. Alarm 2 Low Value
..9999 HI-2 Alarm 2 High -999.. Alarm 2 High Value
..9999 A2CR Display color when Alarm 2 triggered GRN Green Color REd Red Color AMbR Amber Color OUt Alarm Latched/Unlatched selection LAtC Latched UNLA Unlatched NO.CR Display Color in Normal condition GRN Green Color REd Red Color AMbR Amber Color MOdE Data Flow Mode HOSt Host Mode SLAV Slave Mode bAUd Baud Rate 300.. Baud Rate Value
..19200 FORM Data Format 7O1 7 Bit, Odd, 7E1 7 Bit, Even,
1 Stop Bit 1 Stop Bit
8N1 8 Bit, No parity,
1 Stop Bit
COMM Communication Standard 232 RS-232 Standard 485 RS-485 Standard AddR Device Address 0000.. Address Value
..0099 INtF Interface Device dRNt DRN with dRNP DRN with
Temperature Input Process Input
Miscellaneous:
PEAk Peak Value VALL Valley Value PROC Process Value RUN Run Mode OVLd Input Overload StOR Stored Message
1. In Slave Mode the Big Display will wait for
commands and data from the Serial Bus.
2. In Host Mode the Big Display will send data
automatically and continuously into the Serial Bus.
3. When used in RS-485 Mode, the device must be accessed with an appropriate Address Value.
4. Latched Mode: Alarm remains latched until reset. To reset already latched alarm select any menu items and then press “up” or “down” button.
FLOW CHART _____Underline denotes factory default setup
Below is a flowchart showing how to navigate through all menus by pressing front buttons.
M4191/0405
USA
MADE IN
iLD24-C2
Big Remote Display
with RS-232 Input
OPERATION MANUAL
WARRANTY/DISCLAIMER
OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of one (1) year from the date of purchase. In addition to OMEGA’s standard warranty period, OMEGA Engineering will extend the warranty period for four (4) additional years if the warranty card enclosed with each instrument is returned to OMEGA.
If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer Service Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of having been damaged as a result of excessive corrosion; or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating conditions outside of OMEGA’s control. Components which wear are not warranted, including but not limited to contact points, fuses, and triacs.
OMEGA is pleased to offer suggestions on the use of its various products. However, OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by it will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESS OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of OMEGAwith respect to this order, whether based on contract, warranty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event shall OMEGA be liable for consequential, incidental or special damages.
CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical applications or used on humans. Should any Product(s) be used in or with any nuclear installation or activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility as set forth in our basic WARRANTY/DISCLAIMER language, and, additionally, purchaser will indemnify OMEGA and hold OMEGAharmless from any liability or damage whatsoever arising out of the use of the Product(s) in such a manner.
RETURN REQUESTS/INQUIRIES
Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return package and on any correspondence.
The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in transit.
FOR W
ARRANTY RETURNS, please have the following information available BEFORE contacting OMEGA:
1. Purchase Order number under which the product
was PURCHASED,
2. Model and serial number of the product under
warranty, and
3. Repair instructions and/or specific problems
relative to the product.
FOR NON-W
ARRANTY REPAIRS, consult OMEGA for current repair charges. Have the following information available BEFORE contacting OMEGA:
1. Purchase Order number to cover the COST of the
repair,
2. Model and serial number of product, and
3. Repair instructions and/or specific problems
relative to the product.
OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords our customers the latest in technology and engineering.
© Copyright 2002 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without the prior written consent of OMEGA ENGINEERING, INC.
PATENT AND TRADEMARK NOTICE: This product is covered by one or more of the following patents: U.S. Pat. No. Des. 336,895; 5,274,577; 6,243,021/ CANADA2052599; 2052600/ ITALY 1249456; 1250938/ GERMANYDE 41 34398 C2/ SPAIN 2039150; 2048066/ UK Patent No. GB2 249 837; GB2 248 954/ FRANCE BREVET NO. 91 12756. Other U.S. and International Patents pending or applied for.
This device is marked with the international caution symbol. It is important to read the Setup Guide before installing or commissioning this device, as the guide contains important information relating to safety and EMC.
WARNING: These products are not designed for use in, and should not be used for, patient­connected applications.
It is the policy of OMEGA to comply with all worldwide safety and EMC/EMI regulations that apply. OEMGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification.
The information contained in this document is believed to be correct, but OMEGA Engineering, Inc. accepts no liability for any errors it contains, and reserves the right to alter specifications without notice.
TRADEMARK NOTICE:
®
, omega.com
®
, , and
are Trademarks of
OMEGA ENGINEERING, INC.
®
ddddddd
aaaaaaa
bc
d
cbd cbdd
cb
d
d
a
cb
cb
d
a
cb
a
ddd
cbcb
dd
a
cb
cb
a
cb
d
d
a
cb
d
cb
a
cb
a
ddd
dd
a
cb
cb
a
cb cbcbcbcbcb
d
d
a
d
d
d
d
d
d
d
®
®
OMEGAnet® On-Line Service
www.omega.com
Servicing North America:
USA: One Omega Drive, P.O. Box 4047
ISO 9001 Certified Stamford CT 06907-0047
TEL: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com
Canada: 976 Bergar Laval (Quebec) H7L 5A1 TEL: (514) 856-6928 FAX: (514) 856-6886 e-mail: info@omega.ca
For immediate technical or application assistance:
USA and Canada: Sales Service: 1-800-826-6342 / 1-800-TC-OMEGA Customer Service: 1-800-622-2378 / 1-800-622-BEST Engineering Service: 1-800-872-9436 / 1-800-USA-WHEN
Mexico and TEL: (001)800-TC-OMEGA® FAX: (001) 203-359-7807 Latin American: En Espa
e-mail: espanol@omega.com
ñol: (001) 203-359-7803
Servicing Europe:
Benelux: Postbus 8034, 1180 LA Amstelveen, The Netherlands TEL: +31 20 3472121 FAX: +31 20 6434643 Toll Free in Benelux: 0800 0993344 e-mail: sales@omegaeng.nl
Czech Republic: Frystatska 184, 733 01 Karviná TEL: +420 59 6311899 FAX: +420 59 6311114 e-mail: info@omegashop.cz
France: 11, rue Jacques Cartier, 78280 Guyancourt TEL: +33 1 61 37 29 00 FAX: +33 1 30 57 54 27 Toll Free in France: 0800 466 342
Germany/Austria: Daimlerstrasse 26, D-75392 Deckenpfronn, Germany TEL: +49 7056 9398-0 FAX: +49 7056 9398-29 Toll Free in Germany: 0800 639 7678 e-mail: info@omega.de
United Kingdom: One Omega Drive
ISO 9002 Certified River Bend Technology Centre
Northbank, Irlam Manchester M44 5BD United Kingdom TEL: +44 161 777 6611 FAX: +44 161 777 6622 Toll Free in England: 0800 488 488 e-mail: sales@omega.co.uk
e-mail: sales@omega.fr
Internet e-mail
info@omega.com
®
®
®
2. Wiring RS-485 Interface.
The RS-485 standard (multipoint) allows a computer, one or more devices and Big Displays (up to 32) to be connected using a two­wire connection (half-duplex) plus a common wire to connect to the shield of the cable. It is recommended to use shielded cable with one twisted pair for EMI noise protection.
Connections to the computer are optional.
Example 2:
Alarm 1 setup:
“ON”, Alarm Mode Low “A1LO”, Alarm Low Value “LO-1”=100, Alarm Color “A1CR”=Amber Alarm 2 setup:
“ON”, Alarm Mode LO “A2LO”, Alarm High Value “LO-2”=300, Alarm Color “A2CR”=Red Normal Color:
“NO.CR”=Green
Display colors change sequences:
AMBER I RED I GREEN
-- ------------•-------------------------------•------------------------------ --­0 LO-1 = 100 LO-2 = 300
Example 3:
Alarm 1 setup:
“ON”, Alarm Mode Low/High “A1LH”, Alarm Low Value “LO-1”=100, Alarm High Value “HI-1”=250, Alarm Color “A1CR”=Amber Alarm 2 setup:
“ON”, Alarm Mode Low/High “A2LH”, Alarm Low Value “LO-2”=150, Alarm High value “HI-2”=200, Alarm Color “A2CR”=Red Normal Color:
“NO.CR”=Green
Display colors change sequences:
AMBER I RED I GREEN I RED I AMBER
--➤---------•-----------------•-----------------•-----------------•-----------
0 LO-1 = 100 LO-2 = 150 HI-2 = 200 HI-2 = 250
CONFIGURATION
Button Functions in Configuration Mode
To enter the Menu, the user must first press abutton.
Use this button to advance/navigate to the next menu item. The user can navigate through all the top level menus by pressing a.
While a parameter is being modified, press ato escape without saving the parameter.
Press the up bbutton to scroll through submenu selections. When a numerical value is displayed press this key to increase value of a parameter that is currently being modified.
In the Run Mode pressing bcauses the display to flash the PEAK value several times before returning to the Run Mode.
In the top menu press bcauses the display to return to the Run Mode.
Press the down cbutton to scroll through submenu selections. When a numerical value is displayed press this key to decrease value of a parameter that is currently being modified.
In the Run Mode press c causes the display to flash the Valley value several times before returning to the Run Mode.
In the top menu press c causes the display to return to the Run Mode.
Press this button to access the submenus from a Top Level Menu item.
Press this button to store a submenu selection or after entering a value – the display will flash a
STOR
message to confirm your selection.
x, w, z, and some punctuations are non-printable characters.
d
(ENTER)
c
(DOWN)
b
(UP)
a
(MENU)
Mounting Big Display on Bail:
1. Use the Big Display template to mark the location of
mounting screws on the flat surface.
2.
Be sure to leave enough room around the bail (as noted on the
template drawing) to allow for removal and rotation of the display.
3. The display can be rotated for the best viewing angle.
Disassembly Instruction:
Warning: Disconnect all ac power from the unit before proceeding.
1.
Remove all wiring connections from the rear of the instrument, by unscrewing the power and input connectors.
2.
Remove six screws at the back of the display and back cover.
3. Remove the
Big Display
from the panel.
4. To remove the
Big Display
from the bail, unscrew the two
knobs at each end of the mounting brackets.
DESCRIPTION:
The iLD24 is a 4-digit master/slave display providing remote readout from instruments such as programmable controllers, digital panel meters and other instruments with serial output. Communication interfaces supported are RS-232 or RS-485 standards. Both RS-232 or RS-485 are programmable through front panel buttons.
The Big Display features a large three color programmable display with the capabitity to change color every time an Alarm is triggered.
SAFETY:
• The instrument is a panel mount device protected in accordance with EN61010-1:2001.
EMC:
• Whenever EMC is an issue, always use shielded cables.
• Never run signal and power wires in the same conduit.
• Use signal wire connections with twisted-pair cables.
• Install Ferrite Bead(s) on signal wire close to the instrument if EMC problems persist.
MOUNTING
Mounting Big Display Through Panel:
1.
Using the panel cutout diagram shown above, cut an opening in the panel.
2.
Remove six screws at the back of Big Display to remove back
cover.
3.
Insert the unit into the opening from the front of the panel, so the gasket seals between the bezel and the front of the panel.
4. Align back cover to
Big Display
and reinstall screws.
WIRING
1. W
iring RS-232 Interface.
The RS-232 standard (point-to-point) allows a single device to be connected to the
Big Display
using a three-wire connection (full
duplex).
Device with RS-232 Large Remote Display Pin Function RJ-12 Screw Terminal
Receive (Rx) 4 (Tx) 3 (Tx) Transmit (Tx) 3 (Rx) 2 (Rx) Common Ground (COM) 5 1
3. Power Connection.
Connect the main power connections as shown in the figure below.
OPERATIONS
1. Peak V
alue
(Display in Host Mode)
Press bto request “Peak” value:
a) RS-232 Mode, will send:
*X02 (Interface DRNT), or *X03 (Interface DRNP)
b) RS-485 Mode, will send:
*01X02 (Interface DRNT), or *01X03 (Interface DRNP)
In the examples for RS-485 it is assumed that the device address is 01.
2. V
alley Value (Display on Host Mode)
Press cto request “Valley” value.
a) RS-232 Mode, will send:
*X03 (Interface DRNT), or *X04 (Interface DRNP)
b) RS-485 Mode, will send:
*01X03 (Interface DRNT), or *01X04 (Interface DRNP)
3. Process Value (Display on Host Mode)
Press dto request “Process” Value.
a) RS-232 Mode, will send: *X01 b) RS-485 Mode, will send: *01X01
4. Write alphanumeric characters to the Big Display from the computer (Display in Slave Mode)
a) Single Big Display: (RS232) write 4 characters, then
CR (carriage return)
b) Multiple Big Display: (RS485) write *, device address
(2 digit), CR, 4 characters, then CR
5. Display Color Setup (Alarm Setup)
This menu allows the user to select the color of the display in normal conditions and when alarm is triggered. If user wants the Display to change color every time when both Alarm 1 and Alarm 2 are triggered, the Alarm values should be set in such a way that Alarm 1 is always on the top of Alarm 2 value, otherwise value of the Alarm 1 will overwrite value of Alarm 2 and Display color would not change when Alarm 2 is triggered.
Example 1:
Alarm 1 setup:
“ON”, Alarm Mode High “A1HI”, Alarm High Value “HI-1”=400, Alarm Color “A1CR”=Amber Alarm 2 setup:
“ON”, Alarm Mode High “A2HI”, Alarm High Value “HI-2”=200, Alarm Color “A2CR”=Red Normal Color:
“NO.CR”=Green
Display colors change sequences:
GREEN I RED I AMBER
--➤-------------------------•--------------------------------•----------------
0 HI-2 = 200 HI-1 = 400
Computer Card Device with Remote Display or Converter Box RS-485 Pin Pin Function Function RJ-12 Screw Terminal A, -Tx/-Rx -Tx/-Rx 4 3 B, +Tx/+Rx +Tx/+Rx 3 2 COM COM 1
PJ3
COMM
RJ12 JACK
1 3 5
2 4 6
1 2 3 4 5 6
DEVICE WITH
RS232 OUTPUT
RS232/485
COMM.
RTN
RX
TX
1 2 3
RTN
RX
TB4
TX
REMOTE
AC PWR
TB1DCTB2
1 2 3 1 2 1 2 3 4 5
L N
AC PWR
PROGRAMMER
+ -
DC PWR
TB3
REMOTE
PROGRAMMER
POWER