Omega HHM64 Owner's Manual

OMEGA
HHM64
Digital Multimeter
OMEGAnetSM On-Line Service
Internet e-mail
info@omega.com
For immediate technical or application assistance:
USA and Canada: Mexico and Latin America:
Sales Service: 1-800-826-6342 / 1-800-TC-OMEGA
SM
Tel: (95) 800-TC-OMEGA
SM
Customer Service: 1-800-622-2378 / 1-800-622-BEST
SM
FAX: (95) 203-359-7807
Engineering Service: 1-800-872-9436 / 1-800-USA-WHENSMEn Español: (203) 359-7803
TELEX: 996404 EASYLINK: 62968934 CABLE: OMEGA
e-mail: espanol@omega.com
Servicing North America:
USA: ISO 9001 Certified Canada:
One Omega Drive, Box 4047 976 Bergar
Stamford, CT 06907-0047 Laval (Quebec) H7L5A1
Tel: (203) 359-1660 Tel: (514) 856-6928
FAX: (203)359-7700 FAX: (514) 856-6886
e-mail: info@omega.com e-mail: info@omega.com
Servicing Europe:
Benelux:
Postbus 8034, 1180 LA Amstelveen,
The Netherlands
Tel: (31) 20 6418405 FAX: (31) 20 6434643
Toll Free in Benelux: 06 0993344
e-mail: nl@omega.com
Czech Republic:
ul. Rude armady 1868, 733 01 Karvina-
Hranice, Czech Repubic
Tel: 420 (69) 6311627 FAX: 420 (69)
6311114
e-mail: czech@omega.com
France:
9, rue Denis Papin, 78190 Trappes
Tel: (33) 130-621-400 FAX: (33)130-699-120
Toll Free in France: 0800-4-06342
e-mail: france@omega.com
Germany/Austria:
Daimlerstrasse 26, D-75392
Deckenpfronn, Germany
Tel: 49 (07056) 3017 FAX: 49 (07056) 8540
Toll Free in Germany: 0800 82 66342
e-mail: germany@omega.com
United Kingdom: ISO 9002 Certified
One Omega Drive
Riverbend Technology Centre Northbank, Irlam,
Manchester, M44 5EX, England
Tel: 44 (161) 777-6611 FAX: 44 (161) 777-6622
Toll Free in England: 0800-488-488
e-mail: sales@omega.com.uk
omega.com
TM
SAFETY INFORMATION
The following safety information must be observed to insure maximum
personal safety during the operation at this meter:
1. Do not use the meter if the meter or test leads look damaged, or if you suspect that the meter is not operating properly.
2. This meter is not recommended for high voltage industrial use; for example, not for measurements of 440 VAC or 600 VAC industrial power mains. The unit is intended for use with low energy circuits to 600V AC/DC or high energy circuit to 250 VAC or DC.
3. Use caution when working above 60V dc or 30V ac rms. Such voltages pose a shock hazard.
4. When using the probes, keep your fingers behind the finger guards on the probes.
5. Measuring voltage which exceeds the limits of the meter may cause damage and expose the operator to a shock hazard. Always respect the voltage limits as stated on the meter.
6. If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.
1
SPECIFICATIONS
Display: 3½ digit liquid crystal display (LCD) with a maximum reading of 3200. Analog bar graph: 32 segments with measurements 12 times per second. Polarity: Automatic, (-) negative polarity indication. Overrange: "OL" mark indication. Low battery indication: The " " is displayed when the battery voltage drops
below the operating level.
Auto power-down: After 10 mins, Back-Light after 30 secs approx. Measurement rate: 2 times per second, nominal. Operating environment: 0°C to 50°C at <70% relative humidity. Storage environment: -20°C to 60°C at <80% relative humidity. Safety: According to EN61010-1 protection class II overvoltage category (CAT
II 600V) pollution degree 2.
Power: 4 pcs 1.5V (AAA size). Battery life: 500 hours typical. Dimensions: 170mm (H) x 44mm (W) x 40mm (D). Weight: 140g including batteries.
2
DC Voltage (50Hz - 400Hz)
Ranges 320mV, 3.2V, 32V, 320V, 600V Accuracy ±0.25%rdg + 1digit Input impedance 320mV: >1000MW ;
3.2V: 11MW , 32V to 600V: 10MW
Maximum input 600VDC or AC rms
AC Voltage (50Hz - 400Hz)
Ranges 3.2V, 32V, 320V, 600V Accuracy ±0.75%rdg + 4digits Input impedance 320mV: >1000MW ;
3.2V: 11MW , 32V to 600V: 10MW
Maximum input 600VDC or AC rms
3