Omega HHM30 User guide

Page 1
OMEGA
HHM30
Digital LCR Meter
Page 2
omega. com
OMEGAnetSM On-Line Service
http://www.omega.com
USA: ISO 9001 Certified Canada:
One Omega Drive, Box 4047 976 Bergar
Stamford, CT 06907-0047 Laval (Quebec) H7L5A1
Tel: (203) 359-1660 Tel: (514) 856-6928
FAX: (203)359-7700 FAX: (514) 856-6886
USA and Canada: Mexico and Latin America:
Sales Service: 1-800-826-6342 / 1-800-TC-OMEGA
Customer Service: 1-800-622-2378 / 1-800-622-BEST
Engineering Service: 1-800-872-9436 / 1-800-USA-WHENSMEn Español: (203) 359-7803
TELEX: 996404 EASYLINK: 62968934 CABLE: OMEGA e-mail: [email protected]
Benelux: Germany/Austria:
Postbus 8034, 1180 LA Amstelveen, Daimlerstrasse 26, D-75392
The Netherlands Deckenpfronn, Germany
Tel: (31) 20 6418405 FAX: (31) 20 6434643 Tel: 49 (07056) 3017 FAX: 49 (07056) 8540
Toll Free in Benelux: 06 0993344 Toll Free in Germany: 0800 82 66342
Czech Republic: United Kingdom: ISO 9002 Certified
ul. Rude armady 1868, 733 01 Karvina- One Omega Drive
Hranice, Czech Repubic Riverbend Technology Centre Northbank, Irlam,
Tel: 420 (69) 6311627 FAX: 420 (69) 6311114 Manchester, M44 5EX, England
e-mail: [email protected] Tel: 44 (161) 777-6611 FAX: 44 (161) 777-6622
France:
9, rue Denis Papin, 78190 Trappes Toll Free in England: 0800-488-488
Tel: (33) 130-621-400 FAX: (33)130-699-120 e-mail: [email protected]
Toll Free in France: 0800-4-06342
It is the policy of OMEGA to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification. The information contained in this document is believed to be correct but OMEGA Engineering, Inc. accepts no liability for any errors it contains, and reserves the right to alter specifications without notice. WARNING: These products are not designed for use in, and should not be used for, patient connected application.
For immediate technical or application assistance:
Servicing North America:
SM
SM
Servicing Europe:
TM
Internet e-mail
Tel: (95) 800-TC-OMEGA
FAX: (95) 203-359-7807
SM
Page 3
SPECIFICATIONS
Display: 3½ digit liquid crystal display (LCD) with a maximum reading of 1999. Polarity: Automatic, positive implied, negative polarity indication. Overrange: (OL) or (-OL) is displayed. Zero: Automatic. Low battery indication: the " " is displayed when the battery voltage drops
below the operating level.
Measurement rate: 2.5 times per second, nominal. Operating Environment: 0°C to 40°C at < 70% relative humidity. Storage Temperature: -20°C to 60°C, 0 to 80% R.H. with battery removed
from meter.
Accuracy: Stated accuracy at 23°C ± 5°C, <75% relative humidity. Power: single standard 9-volt battery. Battery life: 30 hours typical. Dimensions: 200mm (H) x 90mm (W) x 40mm (D). Weight: Approx. 14 oz. (400g) including battery. Accessories: One pair test leads, One spare fuse installed, 9V battery and
Operating Instructions.
1
Page 4
RESISTANCE
Ranges: 20W,200W ,2KW,20KW,200KW ,2MW ,20MW Resolution: 20Wrange 10mW Accuracy: ±(1.0%rdg + 10dgts) on 20W range
±(0.3%rdg + 3dgts) on 200W range ±(0.3%rdg + 1dgt) on 2KW to 2MW ranges ±(2.0%rdg + 2dgts) on 20MW range
Open circuit volts:
6.5VDC on 20W to 200W Ranges
1.2VDC on other range
Overload protection: All ranges 25VDC or AC rms
Note: in the range 20
WW
, subtract residual offset reading from result.
W
WW
DIODE TEST
éé
Including: , , microwave , zener (<6.8V) Test current: 3mA (approx) Open voltage: 8VDC typical Accuracy: ±(10%rdg +10dgts) Display: forward junction voltage Overload protection: 25VDC or AC rms
2
Page 5
CAPACITANCE
Ranges: 200pF,2nF,20nF,200nF,2µF,20µF,200µF,2000µF Accuracy: ±(1.0%rdg + 3dgts) on 200pF to 200nF ranges
±(2.0%rdg + 3dgts) on 2µF to 200µF ranges ±(3.0%rdg + 3dgts) on 2000µF range: £1000µF ±(5.0%rdg + 10dgts) >1000µF
Test freguency:
1000Hz on 200pF to 2µF range 100Hz on 20µF to 200µF range 10Hz on 2000µF range
Temperature Coefficient:
£0.5µF: 0.1%/°C >0.5µF: 0.2%/°C
Overload protection: 0.1A/250V fast blow fuse
Note: in lower range 200pF, 2nF subtract residual offset reading from result with test leads opening.
3
Page 6
INDUCTANCE
Ranges: 200µH,2mH,20mH,200mH,2H,20H,200H Accuracy: ±(3.0%rdg + 3dgts) on 200µH to 200mH ranges
±(5.0%rdg + 10dgts) on 2H to 200H ranges
Test freguency:
1000Hz on 200µH to 2H ranges 100Hz on 20H to 200H ranges
Temperature Coefficient:
£0.5H: 0.2%/°C >0.5H: 0.5%/°C
Overload protection: 0.1A/250V fast blow fuse
Note: in lower range 200µH, 2mH subtract residual offset reading from result with test leads being shorted.
4
Page 7
OPERATION
However, electrical noise or intense electromagnetic fields in the equip­ment may disturb the measurement circuit. Measuring instruments will also respond to unwanted signals that may be present within the measurement circuit. Users should exercise care and take appropriate precautions to avoid misleading results when making measurements in the presence of elec­tronic interference.
Capacitance
1.Dischange capacitors before trying to measure it.
2.Set the Range to the desired C range.
3.Insert the leads directly in to socket or test leads sockets.
4.Never apply an external voltage to sockets damage to the meter may
resuet.
5.Read the capacitance directly from the display.
Note: in lower range 200pF, 2nF subtract residual offset reading from result with test leads opening.
5
Page 8
Inductance
1. Set the Ranges to the desired L range.
2. never apply an external voltage to the sockets damage to the meter may
result.
3. Insert the inductor leads derectly into sockets or test leards sockets.
4.Read the inductance directly from the display.
Note:in loues range 200µH, 2mH subtract residual offset reading from
result with test leads being shorted.
Resistance
1. Set the Function/Range switch to the desired resistance range.
2. Remove power from the equipment under test.
3. Connect the red test lead to the
-
" jack.
4. Touch the probes to the test points. In ohms, the value indicated in the
display is the measured value of resistance.
WARNING
The accuracy of the functions might be slightly affected, when exposed
to a radiated electromagnetic field environment, eg, radio, telephone or
similar.
Note:in the range 20
WW
, subtract residual offset reading from result.
W
WW
WW
W " + " jack and the black test lead to the
WW
6
WW
W"
WW
Page 9
Diode Tests and Continuity Measurements
1. Connect the red test lead to the " + " jack and the black test lead to the
" - " jack.
2. Set the Function/Range switch to the , , microwave , zener
éé
position.
3. Turn off power to the circuit under test.
4. Touch probes to diodes. A forward-voltage drop on diode. microwave diode
about 0.6VDC typical, LED about 2VDC typical, zener diode about its shown
voltage .
5. Reverse probes. if the diode is good, diode, microwave diode. LED about
open voltage 8VDC typical, zener diode about 0.7V typical.
6. If the junction is measured in a circuit and a low reading is obtained with both
lead connections, the junction may be shunted by a resistance of less than
1kW. In this case the diode must be disconnected from the circuit for
accurate testing.
7
Page 10
MAINTENANCE
WARNING
Remove test leads before changing battery or fuse
or performing any servicing.
Battery Replacement
Power is supplied by a 9 volt "transistor" battery. (NEDA 1604 IEC 6F22). The " " appears on the LCD display when replacement is needed. To replace the battery, remove the two screws from the back of the meter and lift off the battery case. Remove the battery from battery contacts.
Fuse Replacement
If no capacitance and inductance measurements are possible, check for a blown overload protection fuse.For access to fuses, remove the two screws from the back of the meter and lift off the battery case. Replace F1 only with the original type 0.1A/250V, fast acting fuse.
Cleaning
Periodically wipe the case with a damp cloth and detergent, do not use abrasives or solvents.
8
Page 11
OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA Warranty adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA's customers receive maximum cov erage on each product.If the unit should malfunction, it must be returned to the factory for evaluation. OMEGA's Customer Service Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective it will be repaired or replaced at no charge. OMEGA's W ARRANTY does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modification. This WARRANTY is V OID if the unit shows e vidence of having been tampered with or shows evidence of being damaged as a result of excessive corrosion; or current, heat moisture or vibration; improper specification; misapplication; misuse or other operating conditions outside of OMEGA's control. Components which wear are not warranted, including but not limited to contact points, fuses, and triacs.
OMEGA is pleased to offer suggestions on the use of its various products. However , OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for an y damages that result fr om the use of its products in accordance with information provided by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by it will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive and the total liability of OMEGA with respect to this order, whether based on contract, warranty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event shall OMEGA be liable for consequential, incidental or special damages.
CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a "Basic Component" under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical applications or used on humans. Should any Product(s) be used in or with any nuclear installation or activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility as set forth in our basic WARRANTY / DISCLAIMER language, and additionally, purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product(s) in such a manner.
Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGA'S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return package and on any correspondence. The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in transit.
FOR WARRANTY RETURNS, please have the f ollowing
information available BEFORE contacting OMEGA:
1. P.O. number under which the product was PURCHASED.
2. Model and serial number of the product under warranty , and
3. Repair instructions and/or specific problems relative to the
product.
OMEGA's policy is to make running changes, not model changes, whenever an improvement is possible. This affords our customers the latest in technology and engineering. OMEGA is a registered trademark of OMEGA ENGINEERING, INC. © Copyright 1999 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine-readable from, in whole or in part, without prior written consent of OMEGA ENGINEERING, INC.
WARRANTY / DISCLAIMER
RETURN REQUESTS / INQUIRIES
FOR NON-WARRANTY REPAIRS, consult OMEGA for
current repair charges. Have the following information available BEFORE contacting OMEGA:
1. P.O. number to cover the COST of the repair.
2. Model and serial number of product , and
3. Repair instructions and/or specific problems relative to the product.
Page 12
Where Do I Find Everything I Need for
Process Measurement and Control?
OMEGA...Of Course!
TEMPERATURE
þ Thermocouple, RTD & Thermistor
Probes, Connectors, Panels & Assemblies
þ Wire: Thermocouple, RTD & Thermistor
þ Calibrators & Ice Point References
þ Recorders, Controllers & Process Monitors
þ Infrared Pyrometers
PRESSURE/STRAIN AND FORCE
þ Transducers & Strain Gauges
þ Load Cells & Pressure Gauges
þ Displacement Transducers
þ Instrumentation & Accessories
FLOW/LEVEL
þ Rotameters, Gas Mass Flowmeters
& Flow Computers
þ Air Velocity Indicators
þ Turbine/Paddlewheel Systems
þ Totalizers & Batch Controllers
pH/CONDUCTIVITY
þ pH Electrodes, Testers & Accessories
þ Benchtop/Laboratory Meters
þ Controllers, Calibrators, Simulators
& Pumps
þ Industrial pH & Conductivity Equipment
M-2889/0799
DATA ACQUISITION
þ Data Acquisition &
Engineering Software
þ Communications-Based
Acquisition Systems
þ Plug-in Cards for Apple, IBM
& Compatibles
þ Datalogging Systems
þ Recorders, Printers & Plotters
HEATERS
þ Heating Cable
þ Cartridge & Strip Heaters
þ Immersion & Band Heaters
þ Flexible Heaters
þ Laboratory Heaters
ENVIRONMENTAL MONITORING AND CONTROL
þ Metering & Control Instrumentation
þ Refractometers
þ Pumps & Tubing
þ Air, Soil & Water Monitors
þ Industrial Water & Wastewater
Treatment
þ pH, Conductivity & Dissolved Oxygen
Instruments
Loading...